Emma-Lena Maris

Ms. Emma-Lena Maris


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
FOFelix Erik Niels Osinga
Felix Erik Niels Osinga
NHNesar A. Hasami
Nesar A. Hasami
JKJasper Frans de Kort
Jasper Frans de Kort
EMEmma-Lena Maris
Emma-Lena Maris
MDMaurizio Domanin
Maurizio Domanin
STSanti Trimarchi
Santi Trimarchi
Background: Mock circulatory loops (MCLs) are benchtop experimental platforms that reproduce key features of the human cardiovascular system, providing a safe, controlled, and reproducible environment for haemodynamic investigation. This scoping review aims to systematically map the current landscape of MCLs used for aortic simulation and identify major areas of application. Methods: A systematic search of PubMed, Scopus, and Web of Science identified original studies employing MCLs for aortic simulation. Eligible studies were categorized into predefined themes: (I) (bio)mechanical aortic characterization, (II) hemodynamics, (III) device testing, (IV) diagnostics, and (V) training. Data on MCL configurations, aortic models, and study objectives were synthesized narratively. Results: Eighty-four studies met the inclusion criteria. Twenty-five investigated aortic biomechanics, 23 hemodynamics, 22 device or product testing, 13 validated diagnostic imaging techniques, and one training application. Models included porcine (n = 22), human cadaveric (n = 7), canine (n = 1), ovine (n = 1), bovine (n = 1), and 3D-printed or molded aortic phantoms (n = 55). MCLs were employed to study parameters such as aortic stiffness, flow dynamics, dissection propagation, endoleaks, imaging accuracy, and device performance. Conclusions: This review provides a comprehensive overview of MCL applications in aortic research. MCLs represent a versatile pre-clinical platform for studying aortic pathophysiology and testing endovascular therapies under controlled conditions. Standardized reporting frameworks are now required to improve reproducibility and accelerate translation to patient-specific planning.

15 February 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PBPaolo Antonio Bellotti
Paolo Antonio Bellotti
EMEmma-Lena Maris
Emma-Lena Maris
JKJasper Frans de Kort
Jasper Frans de Kort
DBDaniele Bissacco
Daniele Bissacco
SRSilvia Romagnoli
Silvia Romagnoli
STSanti Trimarchi
Santi Trimarchi
Background: Aortic stiffness (AoS) is an established predictor of cardiovascular morbidity and mortality. Endovascular aneurysm repair (EVAR) introduces a rigid stent-graft into the aorta, potentially increasing AoS and impairing subendocardial perfusion. This prospective study aimed to evaluate changes in AoS and myocardial perfusion following EVAR, measured by carotid-to-femoral pulse wave velocity (cf-PWV) and the Subendocardial Viability Ratio (SEVR), and examined the influence of graft length on post-operative cf-PWV and SEVR. Methods: From October 2023 to April 2025, 38 patients undergoing elective EVAR were prospectively enrolled. Cf-PWV and the SEVR were measured <72 h preoperatively and 7 days postoperatively using the PulsePen® device. Descriptive statistics were used to summarize baseline characteristics. Data were assessed for normality with the Shapiro–Wilk test; non-normally distributed variables were analysed using the Wilcoxon signed-rank test and presented as median [interquartile range, IQR], while normally distributed variables were analysed using paired t-tests and presented as mean ± standard deviation (SD). Linear regression was applied to evaluate associations between graft length and postoperative changes in cf-PWV and SEVR. Results: Cf-PWV increased significantly after EVAR, with a median within-patient change of 1.0 m/s [IQR 3.1] (p < 0.001), corresponding to a 10.6% increase. The SEVR decreased significantly by 15.1% (p = 0.006). Graft length correlated positively with cf-PWV change, with a 0.2% increase in cf-PWV per millimetre of graft length (r = 0.41; p = 0.029), but not with SEVR (r = 0.058, p = 0.763). Conclusions: EVAR was associated with increased AoS and reduced subendocardial perfusion, with greater stiffness changes observed in patients receiving longer grafts. These preliminary findings highlight important haemodynamic consequences of EVAR and may inform patient selection, postoperative management, and the development of future stent-graft designs to mitigate long-term cardiovascular risk.