Dimitrios Minas

Mr. Dimitrios Minas

Department of Information and Electronic Engineering, International Hellenic University, Thessaloníki, Kentrikí Makedonía, Greece
orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Dimitrios MinasDimitrios Minas
Dimitrios Minas
Kyriakos TsiakmakisKyriakos Tsiakmakis
Kyriakos Tsiakmakis
Argyrios T. HatzopoulosArgyrios T. Hatzopoulos
Argyrios T. Hatzopoulos
Konstantinos A. TsintotasKonstantinos A. Tsintotas
Konstantinos A. Tsintotas
VVVassilis Vassios
Vassilis Vassios
Maria PapadopoulouMaria Papadopoulou
Maria Papadopoulou
This study presents an integrated, low-cost system for measuring extremely small displacements in Ionic Polymer–Metal Composite (IPMC) actuators operating in aqueous environments. A custom optical setup was developed, combining a glass tank, a tubular microscope with a 10× achromatic objective, a digital USB camera and uniform LED backlighting, enabling side-view imaging of the actuator with high contrast. The microscopy system achieves a spatial sampling of 0.536 μm/pixel on the horizontal axis and 0.518 μm/pixel on the vertical axis, while lens distortion is limited to a maximum edge deviation of +0.015 μm/pixel (≈+2.8%), ensuring consistent geometric magnification across the field of view. On the image-processing side, a predictive grid-based tracking algorithm is introduced to localize the free tip of the IPMC. The method combines edge detection, Harris corners and a constant-length geometric constraint with an adaptive search over selected grid cells. On 1920 × 1080-pixel frames, the proposed algorithm achieves a mean processing time of about 10 ms per frame and a frame-level detection accuracy of approximately 99% (98.3–99.4% depending on the allowed search radius) for actuation frequencies below 2 Hz, enabling real-time monitoring at 30 fps. In parallel, dedicated electronic circuitry for supply and load monitoring provides overvoltage, undervoltage, open-circuit and short-circuit detection in 100 injected fault events, all faults were detected and no spurious triggers over 3 h of nominal operation. The proposed microscopy and tracking framework offer a compact, reproducible and high-resolution alternative to laser-based or Digital Image Correlation techniques for IPMC displacement characterization and can be extended to other micro-displacement sensing applications in submerged or challenging environments.