Argyrios T. Hatzopoulos

Prof. Dr. Argyrios T. Hatzopoulos

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Dimitrios MinasDimitrios Minas
Dimitrios Minas
Kyriakos TsiakmakisKyriakos Tsiakmakis
Kyriakos Tsiakmakis
Argyrios T. HatzopoulosArgyrios T. Hatzopoulos
Argyrios T. Hatzopoulos
Konstantinos A. TsintotasKonstantinos A. Tsintotas
Konstantinos A. Tsintotas
VVVassilis Vassios
Vassilis Vassios
Maria PapadopoulouMaria Papadopoulou
Maria Papadopoulou
This study presents an integrated, low-cost system for measuring extremely small displacements in Ionic Polymer–Metal Composite (IPMC) actuators operating in aqueous environments. A custom optical setup was developed, combining a glass tank, a tubular microscope with a 10× achromatic objective, a digital USB camera and uniform LED backlighting, enabling side-view imaging of the actuator with high contrast. The microscopy system achieves a spatial sampling of 0.536 μm/pixel on the horizontal axis and 0.518 μm/pixel on the vertical axis, while lens distortion is limited to a maximum edge deviation of +0.015 μm/pixel (≈+2.8%), ensuring consistent geometric magnification across the field of view. On the image-processing side, a predictive grid-based tracking algorithm is introduced to localize the free tip of the IPMC. The method combines edge detection, Harris corners and a constant-length geometric constraint with an adaptive search over selected grid cells. On 1920 × 1080-pixel frames, the proposed algorithm achieves a mean processing time of about 10 ms per frame and a frame-level detection accuracy of approximately 99% (98.3–99.4% depending on the allowed search radius) for actuation frequencies below 2 Hz, enabling real-time monitoring at 30 fps. In parallel, dedicated electronic circuitry for supply and load monitoring provides overvoltage, undervoltage, open-circuit and short-circuit detection in 100 injected fault events, all faults were detected and no spurious triggers over 3 h of nominal operation. The proposed microscopy and tracking framework offer a compact, reproducible and high-resolution alternative to laser-based or Digital Image Correlation techniques for IPMC displacement characterization and can be extended to other micro-displacement sensing applications in submerged or challenging environments.

14 February 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
VVVassilis Vassios
Vassilis Vassios
Argyrios T. HatzopoulosArgyrios T. Hatzopoulos
Argyrios T. Hatzopoulos
IIIoannis Intzes
Ioannis Intzes
Kyriakos TsiakmakisKyriakos Tsiakmakis
Kyriakos Tsiakmakis
Dimitrios PapakostasDimitrios Papakostas
Dimitrios Papakostas
This work presents a low-complexity fault detection technique for analog circuits. In this technique, the transient in the power supply current is measured and the decomposition to its mean and rms components is utilized. The classifier signatures are produced from specific points in the rms and mean transients of the power supply current. These points create a reliable detection region/library using the standard deviation in which all other circuits under test are compared to. The main feature of the algorithm is that it is self-trained. With every circuit that is tested, the classification boundaries are updated with the use of recursive calculations of the mean and standard deviation. This eliminates the need for a large number of simulations and/or training runs. The algorithm was tested in simulations and in real circuits with the use of microcontroller-based automated test equipment (ATE) to demonstrate the simplicity and speed of the method. The algorithm was tested on different test bench analog circuits and the results are presented.

1 October 2025 in Agriengineering
Verified
Journal Article
Open access
PDF file
ETEmmanouil Teletos
Emmanouil Teletos
Kyriakos TsiakmakisKyriakos Tsiakmakis
Kyriakos Tsiakmakis
Argyrios T. HatzopoulosArgyrios T. Hatzopoulos
Argyrios T. Hatzopoulos
Stefanos StefanouStefanos Stefanou
Stefanos Stefanou
Soil electrical conductivity (EC) and water content are key indicators of soil health, influencing nutrient availability, salinity stress, and crop productivity. Monitoring these parameters is critical for precision agriculture. However, most existing measurement systems are costly, which restricts their use in practical field conditions. The aim of this study was to develop and validate a low-cost, portable system for simultaneous measurement of soil EC, water content, and temperature, while maintaining accuracy comparable to laboratory-grade instruments. The system was designed with four electrodes arranged in two pairs and employed an AC bipolar pulse method with a constant-current circuit, precision rectifier, and peak detector to minimize electrode polarization. Experiments were carried out in sandy loam soil at water contents of 13%, 18%, and 22% and KNO3 concentrations of 0, 0.1, 0.2, and 0.4 M. Measurements from the developed system were benchmarked against a professional impedance analyzer (E4990A). The findings demonstrated that EC increased with both frequency and water content. At 100 Hz, the mean error compared with the analyzer was 8.95%, rising slightly to 9.98% at 10 kHz. A strong linear relationship was observed between EC and KNO3 concentration at 100 Hz (R2 = 0.9898), and for the same salt concentration (0.1 M KNO3) at 100 Hz, EC increased from ~0.26 mS/cm at 13% water content to ~0.43 mS/cm at 22%. In conclusion, the developed system consistently achieved <10% error while maintaining a cost of ~€55, significantly lower than commercial devices. These results confirm its potential as an affordable and reliable tool for soil salinity and water content monitoring in precision agriculture.

13 May 2026 in Electronics
Verified
Journal Article
Open access
PDF file
VKVasilis Koufogeorgos
Vasilis Koufogeorgos
Kyriakos TsiakmakisKyriakos Tsiakmakis
Kyriakos Tsiakmakis
VVVassilis Vassios
Vassilis Vassios
Maria PapadopoulouMaria Papadopoulou
Maria Papadopoulou
George KokkonisGeorge Kokkonis
George Kokkonis
Argyrios T. HatzopoulosArgyrios T. Hatzopoulos
Argyrios T. Hatzopoulos
Soil apparent electrical conductivity (ECa), volumetric water content (VWC), and temperature are important parameters for evaluating soil condition and supporting irrigation and crop management practices. This study presents the design and experimental evaluation of a ultra-low-hardware-cost soil sensing system capable of estimating these three parameters through impedance-based measurements at different frequency ranges. The proposed system uses sinusoidal excitation in the kHz range for ECα estimation and in the MHz range for VWC estimation, while temperature is also considered as a relevant factor affecting the electrical behavior of soil. The sensor was experimentally tested on three soil types under two moisture conditions, namely water addition with and without mixing, and the results were compared with those obtained from a commercial instrument (5TE Meter Group). The overall mean error of the developed system, without calibration, was 20.2%, with mean errors of 16.3% for ECa and 24.2% for VWC. Although the accuracy achieved is lower than that of commercial instruments, the results demonstrate that the proposed system can provide a satisfactory preliminary assessment of soil conditions in applications where low cost, simplicity and ease of implementation are important. The results can be significantly improved if calibration is made initially for the soil type of the field to be measured. Electrode geometry, lack of calibration with a larger set of soil samples and PCB implementation issues are the main limitations affecting performance. Overall, the proposed approach shows potential as a supportive tool for low-cost agricultural monitoring and decision-making applications. The implementation of a system that measures soil conductivity and moisture in two frequency ranges measurement (kHz for ECα/MHz for VWC), with synchronous soil temperature measurement, at a particularly low cost, is the innovation of the sensor system.