Scarlat Ohanna Dávila da Trindade

Ms. Scarlat Ohanna Dávila da Trindade


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
MRMayra Resende
Mayra Resende
AFAna Elisa Oliveira Fonseca
Ana Elisa Oliveira Fonseca
TCThaís Cândido
Thaís Cândido
DSDaniela Silva
Daniela Silva
STScarlat Ohanna Dávila da Trindade
Scarlat Ohanna Dávila da Trindade
Arnaldo César PereiraArnaldo César Pereira
Arnaldo César Pereira
Acute Myocardial Infarction (AMI) is a critical cardiac condition that poses a substantial threat to myocardial function. Expedient diagnosis of AMI is paramount and relies on serological assays for rapid and accurate quantification of relevant biomarkers. Electrochemical sensors have emerged as promising candidates for this application, owing to their accessibility, operational simplicity, and high specificity. In this study, we developed a paper-based electrochemical immunosensor to detect cardiac troponin I in serum and saliva specimens. The electrode was fabricated using screen-printing technology with photographic paper as the substrate, employing graphite-based ink, nail polish, and acetone as the solvent. A quasi-reference electrode was constructed using silver powder-based ink, nail polish, and acetone. The immunosensor was prepared by modifying the working electrode with gold nanoparticles (AuNP) functionalized with cardiac troponin I antibodies (anti-cTnI) and bovine serum albumin (BSA). This modified electrode was subsequently used to detect the troponin I antigen. The analyses were performed in 0.1 mol L−1 phosphate buffer medium, pH 7.00, in the presence of 5.0 mmol L−1 of the potassium ferrocyanide probe. The immunosensor exhibited a sensitivity of 0.006 µA/fg mL−1, a limit of detection of 9.83 fg mL−1, and a limit of quantification of 32.79 fg mL−1. Specificity studies conducted in the presence of other macromolecules demonstrated minimal interference, with relative standard deviations (RSD) below 5.00%, indicating a specific interaction with troponin I. Furthermore, the immunosensor demonstrated excellent reproducibility and stability. Upon application to serum and saliva samples, the immunosensor presented recoveries of approximately 99–105%, suggesting its potential applicability in clinical analyses.

3 January 2026 in Analytica
Verified
Journal Article
Open access
PDF file
STScarlat Ohanna Dávila da Trindade
Scarlat Ohanna Dávila da Trindade
TCThaís Cândido
Thaís Cândido
MGMatheus Martins Guedes
Matheus Martins Guedes
Arnaldo César PereiraArnaldo César Pereira
Arnaldo César Pereira
Additive manufacturing, particularly fused deposition modeling (FDM), has emerged as a promising approach for producing electrochemical sensors based on conductive thermoplastic composites. In this study, the effects of various printing parameters (extrusion temperature, layer height and width, printing speed, and the number of conductive layers) on the electrochemical performance of PLA/CB electrodes fabricated via FDM were investigated. Electrochemical impedance spectroscopy analyses showed that properly adjusting these parameters promoted the formation of more efficient conductive pathways and reduced charge transfer resistance during monitoring of the redox behavior of the potassium ferrocyanide/ferricyanide probe. Furthermore, the electrochemical performance of the device was demonstrated through the detection of different model analytes, including dopamine, catechol, hydroquinone, paracetamol, and uric acid. The device was also applied to the determination of dopamine, achieving a detection limit of 0.16 µmol L−1. Overall, the results highlighted that optimizing printing conditions is essential for improving the electrochemical performance of 3D-printed devices, reinforcing the potential of 3D printing as a promising route for the fabrication of electrodes for electroanalytical applications.

1 January 2025 in Revista Virtual de Química
Verified
Journal Article
Closed access
STScarlat Ohanna Dávila da Trindade
Scarlat Ohanna Dávila da Trindade
DSDaniela N. da Silva
Daniela N. da Silva
Arnaldo César PereiraArnaldo César Pereira
Arnaldo César Pereira

1 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
STScarlat Ohanna Dávila da Trindade
Scarlat Ohanna Dávila da Trindade
TCThaís Cândido
Thaís Cândido
MGMatheus Martins Guedes
Matheus Martins Guedes
Arnaldo César PereiraArnaldo César Pereira
Arnaldo César Pereira
Additive manufacturing, particularly fused deposition modeling (FDM), has emerged as a promising approach for producing electrochemical sensors based on conductive thermoplastic composites. In this study, the effects of various printing parameters (extrusion temperature, layer height and width, printing speed, and the number of conductive layers) on the electrochemical performance of PLA/CB electrodes fabricated via FDM were investigated. Electrochemical impedance spectroscopy analyses showed that properly adjusting these parameters promoted the formation of more efficient conductive pathways and reduced charge transfer resistance during the monitoring of the redox behavior of the potassium ferrocyanide/ferricyanide probe. Furthermore, the applicability of the sensor was demonstrated through the determination of dopamine, achieving a detection limit of 0.16 µmol L⁻¹. Overall, the findings highlighted that optimizing printing conditions is essential for enhancing the electrochemical response of the sensors and further strengthened the potential of 3D printing as a promising route for the fabrication of electrodes for electroanalytical applications.