Gabriel Andres Zamorano Nuñez

Gabriel Andres Zamorano Nuñez


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
GNGabriel Andres Zamorano Nuñez
Gabriel Andres Zamorano Nuñez
NONicolás De Jesus Norambuena Ortega
Nicolás De Jesus Norambuena Ortega
ICIsabel Cuevas-Quezada
Isabel Cuevas-Quezada
JRJosé Luís Valín Rivera
José Luís Valín Rivera
JOJavier Ignacio Narea Olmos
Javier Ignacio Narea Olmos
Cristóbal Ignacio Galleguillos KettererCristóbal Ignacio Galleguillos Ketterer
Cristóbal Ignacio Galleguillos Ketterer
Work-related musculoskeletal disorders (MSDs) remain a global occupational health priority, with recognized limitations in current point-in-time assessment methodologies. This research extends prior computer vision ergonomic assessment approaches by implementing biological proprioceptive feedback principles into a continuous, real-time monitoring system. Unlike traditional periodic ergonomic evaluation methods such as “Rapid Upper Limb Assessment” (RULA), our bio-inspired system translates natural proprioceptive mechanisms—which enable continuous postural monitoring through spinal feedback loops operating at 50–150 ms latencies—into automated assessment technology. The system integrates (1) markerless 3D pose estimation via MediaPipe Holistic (33 anatomical landmarks at 30 FPS), (2) depth validation via Orbbec Femto Mega RGB-D camera (640 × 576 resolution, Time-of-Flight sensor), and (3) proprioceptive-inspired alert architecture. Experimental validation with 40 adult participants (age 18–25, n = 26 female, n = 14 male) performing standardized load-lifting tasks (6 kg) demonstrated that 62.5% exhibited critical postural risk (RULA ≥ 5) during dynamic movement versus 7.5% at static rest, with McNemar test p<0.001 (Cohen’s h=1.22, 95% CI: 0.91–0.97). The system achieved 95% Pearson correlation between risk elevation and alert activation, with response latency of 42.1±8.3 ms. This work demonstrates technical feasibility for continuous occupational monitoring. However, long-term prospective studies are required to establish whether continuous real-time feedback reduces workplace injury incidence. The biomimetic design framework provides a systematic foundation for translating biological feedback principles into occupational health technology.