Issa Ramaji

Dr. Issa Ramaji

School of Engineering, Computing and Construction Management, Roger Williams University, Bristol, RI 02809, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2025 in Buildings
Verified
Journal Article
Open access
PDF file
FHFaeze Hodavand
Faeze Hodavand
Issa RamajiIssa Ramaji
Issa Ramaji
NSNaimeh Sadeghi
Naimeh Sadeghi
Sarmad Zandi GoharriziSarmad Zandi Goharrizi
Sarmad Zandi Goharrizi
The growing complexity of modern building systems requires advanced monitoring frameworks to improve fault detection, energy efficiency, and operational resilience. Digital Twin (DT) technology, which integrates real-time data with virtual models of physical systems, has emerged as a promising enabler for predictive diagnostics. Despite growing interest, key challenges remain, including the neglect of short- and long-term forecasting across different scenarios, insufficiently robust data preparation, and the rare validation of models on multi-zone buildings over extended test periods. To address these gaps, this study presents a comprehensive DT-enabled framework for predictive monitoring and anomaly detection, validated in a multi-zone educational building in Rhode Island, USA, using a full year of operational data for validation. The proposed framework integrates a robust data processing pipeline and a comparative analysis of machine learning models, including LSTM, RNN, GRU, ANN, XGBoost, and RF, to forecast short-term (1 h) and long-term (24 h) indoor temperature variations. The LSTM model consistently outperformed other methods, achieving R2 > 0.98 and RMSE < 0.55 °C for all tested rooms. For real-time anomaly detection, we applied the hybrid LSTM–Interquartile Range (IQR) method on one-step-ahead residuals, which successfully identified anomalous deviations from expected patterns. The model’s predictions remained within a ±1 °C error margin for over 90% of the test data, providing reliable forecasting up to 16 h ahead. This study contributes a validated, generalizable DT methodology that addresses key research gaps, offering practical tools for predictive maintenance and operational optimization in complex building environments.

14 February 2020 in Journal of Information Technology in Construction
Verified
Journal Article
Open access
PDF file
Issa RamajiIssa Ramaji
Issa Ramaji
Ali MemariAli Memari
Ali Memari
Journal of Information Technology in Construction