TYTingting Yu
Tingting Yu
In this paper, an experimental study of a system for heating an air-conditioned bed during a 2 h lunch was carried out. The results show that the power consumption of heat conduction heating was only 0.34 kW·h and that the average heat dissipation was 81.3 W, while the power consumption of convection heating was 1.43 kW·h, accompanied by an average heat dissipation of 748.7 W. Regardless of the power consumption or the heat dissipation, the convection heating was significantly higher than the heat conduction heating. As a result, the room air temperature increased from 12.3 °C to 17.3 °C under convection heating, but only increased from 14.4 °C to 15.2 °C under heat conduction heating. The study results indicate that when using heat conduction heating, water temperatures in the range of 38~40 °C could meet the thermal comfort needs of the human body; however, a higher temperature range was required when using convection heating. In contrast, the grade of the hot water required for heat conduction heating was lower. It was also found that the temperature under convection heating rises faster, but it tends to lead to a dry feeling after a long time, while the conductive heating showed a slower temperature rise. There was a cool feeling for 20 min when the heating started, and then the thermal comfort improved. The air-conditioning system in this paper was investigated in a heating experiment in the winter lunch break mode and compared with convection heating. The heat conduction heating resulted in better thermal comfort and higher energy efficiency. It is suggested to adopt the heat conduction heating mode in the winter heating operation of this system.

16 March 2026 in Buildings
Verified
Journal Article
Open access
PDF file
TYTingting Yu
Tingting Yu
JJjunjie Jin
junjie Jin
JZJingru Zhang
Jingru Zhang
SWShichao Wang
Shichao Wang
XZXubo Zhao
Xubo Zhao
ZLZihui Li
Zihui Li
With the escalating energy consumption of air conditioning systems worldwide, reducing such energy use has become a critical research priority. Evaporative cooling technology plays a significant role in reducing the energy consumption of existing air conditioning systems, especially by enhancing the heat exchange efficiency of condensers. This paper presents the design of an evaporative cooling household split-type air conditioner (SAC) that employs a submerged water method. By utilizing motor-driven rotation, the water distributor ensures full and even water distribution across a double-layer wet pad. Additionally, condensate water is recycled, and direct evaporative cooling (DEC) technology is applied to lower the condenser temperature, thereby achieving energy savings. Experiments were conducted under various meteorological conditions, comparing the performance of the split air conditioning system with the water distributor to that of the system without it. The comparative experiments revealed that the average air temperature differences at the inlet and outlet of the water distributor were 8.7 °C and 4.8 °C, respectively, with maximum air temperature differences reaching 12.3 °C and 8.2 °C, respectively. Compared to the system without the water distributor, the average condensing temperature at the condenser outlet of the system with the water distributor was reduced by 2.6 °C and 2.1 °C. Moreover, within an 11 h operation period, the average system coefficient of performance (COP) increased by 22.6% and 18.2%, respectively, and the energy savings reached 17.9% and 12.7%, respectively.

5 July 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
JJjunjie Jin
junjie Jin
PBPeiyao Buan
Peiyao Buan
YLYu Liu
Yu Liu
HCHonglin Chen
Honglin Chen
TYTingting Yu
Tingting Yu
In this paper, the experimental study of heating in 2 h lunch mode of air-conditioned bed system is carried out. The results show that the power consumption of heat conduction heating is only 0.34 kW·h, and the average heat dissipation is 81.3 W, while the power consumption of convection heating is 1.43 kW·h, with an average heat dissipation of 748.7 W. Regardless of power consumption or heat dissipation, convection heating is significantly higher than heat conduction heating, resulting in the room air temperature of the former increased from 12.3 °C to 17.3 °C, while the latter only increased from 14.4 °C to 15.2 °C. The study found that the water temperature of heat conduction heating can meet the thermal comfort needs of the human body in the range of 38~40 °C, while convection heating requires a higher temperature range, In contrast, the grade of hot water required for heat conduction heating is lower. Through the experiment, it is also found that the temperature of convection heating rises fast, but it is easy to appear dry feeling after a long time, while heat conductive heating has a slow temperature rise. there is a cool feeling within 20 min after the heating starts, and then the thermal comfort is better. The air conditioning system in this paper is used for the heating experiment in the winter lunch break mode, compared with convection heating, the overall thermal comfort of heat conduction heating is better and more energy efficient. it is suggested to adopt heat conduction heating mode in the winter heating of this system.