Variations in slag properties critically influence smelting operations and product quality. The effects of K2O on the CaO-SiO2-MgO-Al2O3-K2O slag system at 1823 K were systematically analyzed through an integrated approach combining viscosity measurements, FTIR spectroscopy, and molecular dynamics simulations. The results revealed a rapid 52% decrease in slag viscosity and an 18.32 kJ/mol reduction in activation energy as K2O content increased from 0% to 3%. K2O releases O2− ions that depolymerize Si-O network structures. Within the 3% to 5% range, structural network formation is promoted by the K2O-SiO2 reaction, resulting in increased slag viscosity and elevated activation energy. Molecular dynamics simulations elucidate the depolymerization of complex Si-O networks, accompanied by a proliferation of smaller [AlO4] tetrahedral fragments. The diminished Si-O-Si bridging oxygen (BO) bonds contrast with the enhanced increase in Si-O-K non-bridging oxygen (NBO) linkages. When K2O exceeds 3%, the diffusion capacity of K atoms becomes constrained as K2O participates in structural network assembly, a phenomenon validated by FTIR spectroscopic analysis. Elevated K2O concentrations enhance slag network polymerization, leading to increased viscosity. Therefore, the precise control of K2O content is critical during smelting operations and by-product manufacturing (e.g., glass or mineral wool) to optimize material performance. These findings provide theoretical support for controlling the alkali metal content during the actual metallurgical process and thus further optimizing blast furnace operation.
In this paper, an experimental study of a system for heating an air-conditioned bed during a 2 h lunch was carried out. The results show that the power consumption of heat conduction heating was only 0.34 kW·h and that the average heat dissipation was 81.3 W, while the power consumption of convection heating was 1.43 kW·h, accompanied by an average heat dissipation of 748.7 W. Regardless of the power consumption or the heat dissipation, the convection heating was significantly higher than the heat conduction heating. As a result, the room air temperature increased from 12.3 °C to 17.3 °C under convection heating, but only increased from 14.4 °C to 15.2 °C under heat conduction heating. The study results indicate that when using heat conduction heating, water temperatures in the range of 38~40 °C could meet the thermal comfort needs of the human body; however, a higher temperature range was required when using convection heating. In contrast, the grade of the hot water required for heat conduction heating was lower. It was also found that the temperature under convection heating rises faster, but it tends to lead to a dry feeling after a long time, while the conductive heating showed a slower temperature rise. There was a cool feeling for 20 min when the heating started, and then the thermal comfort improved. The air-conditioning system in this paper was investigated in a heating experiment in the winter lunch break mode and compared with convection heating. The heat conduction heating resulted in better thermal comfort and higher energy efficiency. It is suggested to adopt the heat conduction heating mode in the winter heating operation of this system.
In this paper, the experimental study of heating in 2 h lunch mode of air-conditioned bed system is carried out. The results show that the power consumption of heat conduction heating is only 0.34 kW·h, and the average heat dissipation is 81.3 W, while the power consumption of convection heating is 1.43 kW·h, with an average heat dissipation of 748.7 W. Regardless of power consumption or heat dissipation, convection heating is significantly higher than heat conduction heating, resulting in the room air temperature of the former increased from 12.3 °C to 17.3 °C, while the latter only increased from 14.4 °C to 15.2 °C. The study found that the water temperature of heat conduction heating can meet the thermal comfort needs of the human body in the range of 38~40 °C, while convection heating requires a higher temperature range, In contrast, the grade of hot water required for heat conduction heating is lower. Through the experiment, it is also found that the temperature of convection heating rises fast, but it is easy to appear dry feeling after a long time, while heat conductive heating has a slow temperature rise. there is a cool feeling within 20 min after the heating starts, and then the thermal comfort is better. The air conditioning system in this paper is used for the heating experiment in the winter lunch break mode, compared with convection heating, the overall thermal comfort of heat conduction heating is better and more energy efficient. it is suggested to adopt heat conduction heating mode in the winter heating of this system.