Runze Wu

Dr. Runze Wu


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2020 in British Journal of Radiology
Verified
Journal Article
Closed access
BZBin Zhang
Bin Zhang
CJChunxue Jia
Chunxue Jia
RWRunze Wu
Runze Wu
BLBaotao Lv
Baotao Lv
BLBeibei Li
Beibei Li
XLXiaodog Li
Xiaodog Li
Objectives: To investigate the impact of deep learning (DL) on radiologists’ detection accuracy and reading efficiency of rib fractures on CT. Methods: Blunt chest trauma patients (n = 198) undergoing thin-slice CT were enrolled. Images were read by two radiologists (R1, R2) in three sessions: S1, unassisted reading; S2, assisted by DL as the concurrent reader; S3, DL as the second reader. The fractures detected by the readers and total reading time were documented. The reference standard for rib fractures was established by an expert panel. The sensitivity and false-positives per scan were calculated and compared among S1, S2, and S3. Results: The reference standard identified 865 fractures on 713 ribs (102 patients) The sensitivity of S1, S2, and S3 was 82.8, 88.9, and 88.7% for R1, and 83.9, 88.7, and 88.8% for R2, respectively. The sensitivity of S2 and S3 was significantly higher compared to S1 for both readers (all p < 0.05). The sensitivity between S2 and S3 did not differ significantly (both p > 0.9). The false-positive per scan had no difference between sessions for R1 (p = 0.24) but was lower for S2 and S3 than S1 for R2 (both p < 0.05). Reading time decreased by 36% (R1) and 34% (R2) in S2 compared to S1. Conclusions: Using DL as a concurrent reader can improve the detection accuracy and reading efficiency for rib fracture. Advances in knowledge: DL can be integrated into the radiology workflow to improve the accuracy and reading efficiency of CT rib fracture detection.

17 April 2020 in Medical Physics
Verified
Journal Article
Closed access
PDF file
SYShulin Yao
Shulin Yao
TFTao Feng
Tao Feng
YZYimin Zhao
Yimin Zhao
RWRunze Wu
Runze Wu
RWRuimin Wang
Ruimin Wang
BXBaixuan Xu
Baixuan Xu

16 February 2021 in British Journal of Radiology
Verified
Journal Article
Closed access
FYFeng-Jiao Yang
Feng-Jiao Yang
SAShu-Yue Ai
Shu-Yue Ai
RWRunze Wu
Runze Wu
YLYang Lv
Yang Lv
HXHui-Fang Xie
Hui-Fang Xie
FWFeng Wang
Feng Wang
Objectives: To investigate the impact of total variation regularized expectation maximization (TVREM) reconstruction on the image quality of 68Ga-PSMA-11 PET/CT using phantom and patient data. Methods: Images of a phantom with small hot sphere inserts and 20 prostate cancer patients were acquired with a digital PET/CT using list-mode and reconstructed with ordered subset expectation maximization (OSEM) and TVREM with seven penalisation factors between 0.01 and 0.42 for 2 and 3 minutes-per-bed (m/b) acquisition. The contrast recovery (CR) and background variability (BV) of the phantom, image noise of the liver, and SUVmax of the lesions were measured. Qualitative image quality was scored by two radiologists using a 5-point scale (1-poor, 5-excellent). Results: The performance of CR, BV, and image noise, and the gain of SUVmax was higher for TVREM 2 m/b groups with the penalization of 0.07 to 0.28 compared to OSEM 3 m/b group (all p < 0.05). The image noise of OSEM 3 m/b group was equivalent to TVREM 2 and 3 m/b groups with a penalization of 0.14 and 0.07, while lesions’ SUVmax increased 15 and 20%. The highest qualitative score was attained at the penalization of 0.21 (3.30 ± 0.66) for TVREM 2 m/b groups and the penalization 0.14 (3.80 ± 0.41) for 3 m/b group that equal to or greater than OSEM 3 m/b group (2.90 ± 0.45, p = 0.2 and p < 0.001). Conclusions: TVREM improves lesion contrast and reduces image noise, which allows shorter acquisition with preserved image quality for PSMA PET/CT. Advances in knowledge: TVREM reconstruction with optimized penalization factors can generate higher quality PSMA-PET images for prostate cancer diagnosis.

26 March 2022 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
LXLei Xu
Lei Xu
RLRu-Shuai Li
Ru-Shuai Li
RWRunze Wu
Runze Wu
RYRui Yang
Rui Yang
QYQin-Qin You
Qin-Qin You
QMQing-Le Meng
Qing-Le Meng
Background: To investigate the influence of small voxel Bayesian penalized likelihood (SVB) reconstruction on small lesion detection compared to ordered subset expectation maximization (OSEM) reconstruction using a clinical trials network (CTN) chest phantom and the patients with 18F-FDG-avid small lung tumors, and determine the optimal penalty factor for the lesion depiction and quantification. Methods: The CTN phantom was filled with 18F solution with a sphere-to-background ratio of 3.81:1. Twenty-four patients with 18F-FDG-avid lung lesions (diameter < 2 cm) were enrolled. Six groups of PET images were reconstructed: routine voxel OSEM (RVOSEM), small voxel OSEM (SVOSEM), and SVB reconstructions with four penalty factors: 0.6, 0.8, 0.9, and 1.0 (SVB0.6, SVB0.8, SVB0.9, and SVB1.0). The routine and small voxel sizes are 4 × 4 × 4 and 2 × 2 × 2 mm3. The recovery coefficient (RC) was calculated by dividing the measured activity by the injected activity of the hot spheres in the phantom study. The SUVmax, target-to-liver ratio (TLR), contrast-to-noise ratio (CNR), the volume of the lesions, and the image noise of the liver were measured and calculated in the patient study. Visual image quality of the patient image was scored by two radiologists using a 5-point scale. Results: In the phantom study, SVB0.6, SVB0.8, and SVB0.9 achieved higher RCs than SVOSEM. The RC was higher in SVOSEM than RVOSEM and SVB1.0. In the patient study, the SUVmax, TLR, and visual image quality scores of SVB0.6 to SVB0.9 were higher than those of RVOSEM, while the image noise of SVB0.8 to SVB1.0 was equivalent to or lower than that of RVOSEM. All SVB groups had higher CNRs than RVOSEM, but there was no difference between RVOSEM and SVOSEM. The lesion volumes derived from SVB0.6 to SVB0.9 were accurate, but over-estimated by RVOSEM, SVOSEM, and SVB1.0, using the CT measurement as the standard reference. Conclusions: The SVB reconstruction improved lesion contrast, TLR, CNR, and volumetric quantification accuracy for small lesions compared to RVOSEM reconstruction without image noise degradation or the need of longer emission time. A penalty factor of 0.8–0.9 was optimal for SVB reconstruction for the small tumor detection with 18F-FDG PET/CT.

29 August 2014 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
YWYing Wang
Ying Wang
Xiaohua WangXiaohua Wang
Xiaohua Wang
YZYan Zhang
Yan Zhang
YLYuliu Lu
Yuliu Lu
RWRunze Wu
Runze Wu
HYHui-Shu Yuan
Hui-Shu Yuan

1 January 2024 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
LYLei Yan
Lei Yan
ZWZhao Wang
Zhao Wang
DLDacheng Li
Dacheng Li
YWYangyang Wang
Yangyang Wang
GYGuangjie Yang
Guangjie Yang
ZWZhenguang Wang
Zhenguang Wang
Background: Patients with lymphoma receive multiple positron emission tomography/computed tomography (PET/CT) exams for monitoring of the therapeutic response. With PET imaging, a reduced level of injected fluorine-18 fluorodeoxyglucose ([18F]FDG) activity can be administered while maintaining the image quality. In this study, we investigated the efficacy of applying a deep learning (DL) denoising-technique on image quality and the quantification of metabolic parameters and Deauville score (DS) of a low [18F]FDG dose PET in patients with lymphoma. Methods: This study retrospectively enrolled 62 patients who underwent [18F]FDG PET scans. The low-dose (LD) data were simulated by taking a 50% duration of routine-dose (RD) PET list-mode data in the reconstruction, and a U-Net-based denoising neural network was applied to improve the images of LD PET. The visual image quality score (1 = undiagnostic, 5 = excellent) and DS were assessed in all patients by nuclear radiologists. The maximum, mean, and standard deviation (SD) of the standardized uptake value (SUV) in the liver and mediastinum were measured. In addition, lesions in some patients were segmented using a fixed threshold of 2.5, and their SUV, metabolic tumor volume (MTV), and tumor lesion glycolysis (TLG) were measured. The correlation coefficient and limits of agreement between the RD and LD group were analyzed. Results: The visual image quality of the LD group was improved compared with the RD group. The DS was similar between the RD and LD group, and the negative (DS 1–3) and positive (DS 4–5) results remained unchanged. The correlation coefficients of SUV in the liver, mediastinum, and lesions were all >0.85. The mean differences of SUVmax and SUVmean between the RD and LD groups, respectively, were 0.22 [95% confidence interval (CI): –0.19 to 0.64] and 0.02 (95% CI: –0.17 to 0.20) in the liver, 0.13 (95% CI: –0.17 to 0.42) and 0.02 (95% CI: –0.12 to 0.16) in the mediastinum, and –0.75 (95% CI: –3.42 to 1.91), and –0.13 (95% CI: –0.57 to 0.31) in lesions. The mean differences in MTV and TLG were 0.85 (95% CI: –2.27 to 3.98) and 4.06 (95% CI: –20.53 to 28.64) between the RD and LD groups. Conclusions: The DL denoising technique enables accurate tumor assessment and quantification with LD [18F]FDG PET imaging in patients with lymphoma.