Mehmet Emin Özdemir

Dr. Mehmet Emin Özdemir


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2024 in Journal of Materials Engineering and Performance
Verified
Journal Article
Closed access
PDF file
DSDursun Murat Sekban
Dursun Murat Sekban
EYEcren Uzun Yaylacı
Ecren Uzun Yaylacı
MÖMehmet Emin Özdemir
Mehmet Emin Özdemir
MYMURAT YAYLACI
MURAT YAYLACI
ATAbdelouahed Tounsi
Abdelouahed Tounsi

6 January 2025 in Orthopaedic Surgery
Verified
Journal Article
Open access
YGYılmaz Güvercin
Yılmaz Güvercin
MYMURAT YAYLACI
MURAT YAYLACI
ADAyberk Dizdar
Ayberk Dizdar
MÖMehmet Emin Özdemir
Mehmet Emin Özdemir
SASevil Ay
Sevil Ay
GPGökhan Peker
Gökhan Peker
Objective: Despite several surgical options, there has yet to be a consensus on the best treatment for femoral neck fracture (FNF) due to higher complication rates compared to other bone fractures. This study aims to examine the possible consequences and solution suggestions of changing screws during surgery for various reasons in FNF surgical treatment from a biomechanical perspective.Method: FNF and treatment materials were analyzed biomechanically using a package program based on the finite element method (FEM). This study created a solid model with images of femur bone tomography. Dynamic hip screws (DHS), cannulated screws (CCS), and medial buttress plates (MBP) were obtained by making three‐dimensional designs. The required elements for the models were assigned, and the material properties of the elements were defined. The solutions were obtained as crack distance and deformation results after defining the boundary conditions and applying the necessary loading.Results: The strain and crack distance values created by six models on the fracture line under different parameters were obtained, and the numerical results were evaluated. The DHS and CCS models produced the highest crack distance and deformation values when all screws were loose. The lowest values were obtained in the intact‐85 model when all CCS were tight. When the results are evaluated, it is seen that the MBP has a decreasing effect on the results. Mechanical evaluation of six different options used in femoral neck fractures was performed. 85 mm CCS applied to our standard model gave the best results, while the use of 80 mm CCS in the same model showed promising results compared to other models. It is understood that CCS have the best stability even in loosening models with the medial support plate. Different models are from intact‐85 mm DHS+1CS+MBP to DHS+1CS, which was worked with LSR+USR‐2, according to decreasing stability.Conclusion: This study offers various biomechanical solutions to possible intraoperative problems in FNF treatment. The following results were obtained from the study data. When the CCS needs to be lengthened or replaced, it is appropriate to use the CCS with the MBP. A single anti‐rotation screw is sufficient for lag screw extensions of the DHS plate, and the MBP may be a savior procedure in surgery.

2 October 2024 in ZAMM - Journal of Applied Mathematics and Mechanics / Zeitschrift für Angewandte Mathematik und Mechanik
Verified
Journal Article
Open access
RSRajendran Selvamani
Rajendran Selvamani
PTPrabhakaran Thangamuni
Prabhakaran Thangamuni
MYMURAT YAYLACI
MURAT YAYLACI
MÖMehmet Emin Özdemir
Mehmet Emin Özdemir
EYEcren Uzun Yaylacı
Ecren Uzun Yaylacı
The present study focuses on the modeling and analyzing the nonlinear vibration patterns and parametric excitation of embedded Euler–Bernoulli nanobeams subjected to thermo‐magneto‐mechanical loads. The Euler–Bernoulli nanobeam is developed with external parametric excitation. The governing equation of motion is derived by utilizing nonlocal continuum theory and nonlinear von Karman beam theory. Subsequently, the homotopy perturbation technique is employed to determine the vibration frequencies. Finally, the modulation equation of Euler–Bernoulli nanobeams is derived for simply supported boundary condition. In order to validate our findings, we conduct a comparative analysis against existing literature, thereby underscoring the effectiveness and robustness of our proposed methodology. The influence of stress, magnetic potential, temperature, damping coefficient, Winkler coefficient, and nonlocal parameters are tested numerically on nonlinear frequency‐amplitude and parametric excitation–amplitude responses. The numerical examples indicate the significant impact of physical variables on the nonlinear frequency and parametric excitation. The primary objective of this study is to investigate the effects of external physical variables on the dynamic behavior of nanobeams, particularly in nonlinear regimes. This study provides insights into the design and control of nanostructures under complex load conditions, contributing to developing advanced materials and nanosystems.

4 May 2024 in Mathematical Methods in the Applied Sciences
Verified
Journal Article
Open access
MYMURAT YAYLACI
MURAT YAYLACI
MYMüjgen Yaylı
Müjgen Yaylı
ŞÖŞevval Öztürk
Şevval Öztürk
SASevil Ay
Sevil Ay
MÖMehmet Emin Özdemir
Mehmet Emin Özdemir
ABAhmet Birinci
Ahmet Birinci
This study offers a comparative study of the analytical and numerical methods for investigating a contact problem. The contact problem comprises a functionally graded layer supported by a half‐plane and loaded with a distributed load from the top surface. First, the analytical and numerical solutions to the problem are acquired by utilizing a theory of elasticity and finite element method, respectively. The problem is transformed into a system of integral equations in which the contact stress is an unknown function. The solution of the integral equation was achieved with Gauss–Jacobi integration formulation. The finite element model of the problem is created using ANSYS software, and the two‐dimensional analysis of the problem is performed. Results were obtained from the samples for different material properties and loading conditions. The distributed load width and non‐homogeneity parameters significantly impact on contact mechanics. The results indicate that the contact area and the contact stress obtained from finite element method (FEM) are close to the analytical results. As a result, acceptable error rates were obtained. Finally, this study provides evidence of a good agreement between the two methods.

19 January 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
HYHatice Yemenoglu
Hatice Yemenoglu
MBMelek Beder
Melek Beder
MYMURAT YAYLACI
MURAT YAYLACI
ADAyberk Dizdar
Ayberk Dizdar
MAMURAT ALKURT
MURAT ALKURT
ZDZeynep Yesil Duymus
Zeynep Yesil Duymus
Zygomatic implants are becoming an ideal treatment approach for implant-supported prosthesis treatment developed for the atrophic maxilla. This study aims to evaluate the amount and distribution of stress in implants and peri-implant bone using different implant-supported prosthesis configurations in Aramany Class I maxillary defects through 3-dimensional finite element analysis. A 3-dimensional finite element model of the Aramany class I defect was created. Three different implant-supported prostheses were modelled: model 1: 1 zygomatic implant and 3 dental implants, model 2: 1 zygomatic implant and 2 dental implants, and model 3: 2 zygomatic implants. Vertical and horizontal loads of 150 N were applied in 6 different ways to the defected and non-defective areas. Maximum principal stress and von mises stresses in the bone surrounding the implants were evaluated. When all loading conditions were evaluated with both porcelain layer on Co-Cr framework and acrylic layer on acrylic framework, the highest maximum principal stress value was observed in Model 3. In contrast, the lowest value was observed in Model 1. The highest maximum principal stress occurred when a horizontal load was applied simultaneously to both the defective and non-defective areas. In contrast, the lowest value was observed when a vertical load was applied to the non-defective area. The von Mises stress values were found to be similar across all models when both restoration materials were used. Based on the results of this study, it can be concluded that increasing the number of implants in the non-defective area reduces the highest stress value while using acrylic as a restoration material slightly increases the stress value.

10 February 2026 in Polymers
Verified
Journal Article
Open access
PDF file
BBBaşak Bingöl
Başak Bingöl
SFSamed Oğuzhan Fiat
Samed Oğuzhan Fiat
ÖGÖmer Genç
Ömer Genç
MÖMehmet Emin Özdemir
Mehmet Emin Özdemir
MYMURAT YAYLACI
MURAT YAYLACI
Integrating waste materials into road infrastructure is essential for environmental sustainability and resource efficiency. This study addresses the modification of short-term-aged 50/70-penetration-grade bitumen using two sustainable additives: waste toner powder and lignin. Waste toner was added at weight percentages of 4%, 8%, 12%, and 16%, while lignin was added at 15% and 20%. Since these modifiers have individual uses, this study examines how they may strengthen the oxidized binder. It focuses on extending the lifespan of the mixture by combining industrial and bio-based polymers. The main aim was to delineate the impact of these modifiers on the physical consistency, low-temperature flexibility, and microstructural morphology of the binder. The results show that both modifiers increase binder stiffness by reducing penetration at all modification rates. The resins in the waste toner enhance the polymer matrix, and the lignin’s aromatic structure increases the elastic components, improving high-temperature stability. However, ductility tests showed a reduction in elongation capability, suggesting a brittle state at lower temperatures. Also, waste toner additive is identified as the ideal modifier for high-temperature applications. SEM analysis illuminated the mechanisms underlying these performance modifications. Both additives had homogeneous distribution and good bitumen matrix interfacial bonding at lower concentrations.