Background: One of the primary concerns in the paediatric emergencies is traumatic dental injuries.Objective: This study aimed to create trauma in primary teeth and reveal its effects finite element analysis.Design: Three‐dimensional models were created using cone‐beam computed tomography images, representing a maxillary primary central incisor. An impact force moving at a speed of 10 m/s was simulated on the labial tooth surface in two directions: buccal and incisal.Results: The stress and deformation experienced in the adjacent tooth due to the primary tooth were higher than those generated in the permanent tooth. Forces applied in the incisal direction resulted in higher levels of stress and deformation in the permanent tooth germ. The difference between the stress and deformation values in primary teeth in the forces applied in the buccal and incisal directions is 21% and 75%, respectively; in the permanent tooth germ, this difference was 233% and 100%, respectively.Conclusions: Based on the findings of this study, it is crucial to thoroughly evaluate not only the affected primary tooth but also the adjacent teeth and the permanent tooth germ in traumatic dental injuries. This comprehensive examination allows for the anticipation and management of potential long‐term problems.
Zygomatic implants are becoming an ideal treatment approach for implant-supported prosthesis treatment developed for the atrophic maxilla. This study aims to evaluate the amount and distribution of stress in implants and peri-implant bone using different implant-supported prosthesis configurations in Aramany Class I maxillary defects through 3-dimensional finite element analysis. A 3-dimensional finite element model of the Aramany class I defect was created. Three different implant-supported prostheses were modelled: model 1: 1 zygomatic implant and 3 dental implants, model 2: 1 zygomatic implant and 2 dental implants, and model 3: 2 zygomatic implants. Vertical and horizontal loads of 150 N were applied in 6 different ways to the defected and non-defective areas. Maximum principal stress and von mises stresses in the bone surrounding the implants were evaluated. When all loading conditions were evaluated with both porcelain layer on Co-Cr framework and acrylic layer on acrylic framework, the highest maximum principal stress value was observed in Model 3. In contrast, the lowest value was observed in Model 1. The highest maximum principal stress occurred when a horizontal load was applied simultaneously to both the defective and non-defective areas. In contrast, the lowest value was observed when a vertical load was applied to the non-defective area. The von Mises stress values were found to be similar across all models when both restoration materials were used. Based on the results of this study, it can be concluded that increasing the number of implants in the non-defective area reduces the highest stress value while using acrylic as a restoration material slightly increases the stress value.
4 May 2024 in Mathematical Methods in the Applied Sciences
This study offers a comparative study of the analytical and numerical methods for investigating a contact problem. The contact problem comprises a functionally graded layer supported by a half‐plane and loaded with a distributed load from the top surface. First, the analytical and numerical solutions to the problem are acquired by utilizing a theory of elasticity and finite element method, respectively. The problem is transformed into a system of integral equations in which the contact stress is an unknown function. The solution of the integral equation was achieved with Gauss–Jacobi integration formulation. The finite element model of the problem is created using ANSYS software, and the two‐dimensional analysis of the problem is performed. Results were obtained from the samples for different material properties and loading conditions. The distributed load width and non‐homogeneity parameters significantly impact on contact mechanics. The results indicate that the contact area and the contact stress obtained from finite element method (FEM) are close to the analytical results. As a result, acceptable error rates were obtained. Finally, this study provides evidence of a good agreement between the two methods.
Background/Objectives: Lower-limb amputation presents biomechanical challenges at the residual limb–prosthetic socket interface, where uneven load transfer may generate localized stress concentrations. This study investigates the biomechanical behavior of a patient-specific transfemoral residual limb–prosthesis system with and without a structural implant positioned at the distal femur. Methods: Finite element simulations were performed for three activities: normal walking, stair descent, and stair ascent. Von Mises stress, contact pressure (CPRESS), and longitudinal shear stress (CSHEAR1) were evaluated in the residual limb and prosthetic components. Results: During normal walking, stair descent, and stair ascent, the implant reduced the maximum von Mises stress in the residual limb by 62.9%, 55.1%, and 80.2%, respectively. The maximum longitudinal shear stress in the residual limb decreased by 28.6%, 28.0%, and 41.5%, respectively. During stair descent, the maximum contact pressure at the residual limb interface decreased by 79.4%, from 173 to 35.6 kPa, while during stair ascent it decreased by 38.6%, from 95.5 to 58.6 kPa. The maximum contact pressure on the prosthetic liner decreased by 43.0% during stair descent and 33.7% during stair ascent. Similarly, the maximum longitudinal shear stress on the socket decreased by 43.3% and 33.3%, respectively. However, slight increases in some peak contact and shear stress values were observed during normal walking. These findings indicate that the biomechanical effects of the implant depend on the activity and the parameter evaluated. Conclusions: Although the numerical results demonstrate reductions in several peak stress and pressure values, clinical benefits cannot be established from the simulations alone.