A novel fault location scheme using feeder terminal units (FTUs) for high-impedance grounding faults in resonant grounding systems (RGSs) is presented. The parallel resonance for a high-impedance fault (HIF) in an RGS with inverter-interfaced distributed generators (IIDGs) is analyzed. The process exhibits unique distribution features for transient zero-sequence components involving underdamped and overdamped states. We conclude that the transient zero-sequence admittances (TZSAs) from FTUs upstream of the fault point have the maximum value, while the TZSAs obtained from FTUs downstream of the fault point are small for HIFs. Therefore, the proposed location scheme uses FTUs to calculate the maximum values of the TZSA. By comparing with action criteria, the distribution automation (DA) master station utilizes the above results of each FTU to locate the faulty feeder section. The accuracy of the fault characteristics and the proposed method are validated by applying a real-time digital simulator (RTDS) and an FTU-based monitoring system. Additionally, the proposed scheme demonstrates an excellent and reliable performance, considering various faulty feeder sections, fault resistances, arcing faults, fault inception angles, imbalances and the presence of IIDGs and noise.
1 September 2021 in Computer Methods and Programs in Biomedicine
In this paper, a new approach for enhancing the temperature sensitivity of a resonant MEMS thermometer, based on parametric modulation, is proposed. By periodically modulating the effective stiffness of a standard clamped-clamped beam (C-C beam), which is used as a proof-of-concept resonant MEMS thermometer, it is possible to create a virtual energy coupling between two fundamental modes of vibration. Through this energy transfer link, one particular mode (ideally high sensitivity) can be transferred to the vicinity of another mode (ideally low noise), thus creating an operating region where both increased sensitivity and low noise can be achieved. As a starting point, a sensitivity enhancement of up to 126% can be achieved in this particular study, while not deteriorating the readout noise floor. A noise floor of 19.7 μ K/Hz 1/2 has been achieved. Potentially, this approach could be extended to other structures, or be used to decrease sensitivity to temperature fluctuations as well.
22 June 2022 in Journal of Microelectromechanical Systems
This study reports a closed-loop system (CLS) for resonant micro-electromechanical systems (MEMS) sensors subject to blue-sideband excitation (BSE) for the first time. Compared with the conventional excitation scheme, which uses an AC signal with a frequency that is very close to or equal to that of the desired MEMS resonator mode, the BSE scheme applies an AC signal with a frequency equal to or near the sum of two resonant frequencies to excite the resonator. This requires a CLS to provide a sum-frequency excitation signal to serve as the resonator’s feedback driving signal for practical applications. The proposed CLS mainly consists of a digital lock-in amplifier (DLA), a phase-locked loop (PLL) and a BSE control module (BSE-CM), and is implemented using a field-programmable gate array (FPGA). Experiments showed that the system can track the combined frequency of two flexural modes of the resonator in real-time. In addition, a potential application of the CLS for resonant MEMS sensors subject to BSE is preliminarily demonstrated, showing that the sensitivity of a vacuum-packaged resonant MEMS accelerometer can be enhanced by 166%. This approach could also be applied to reduce the effects of the feedback phase, or to simultaneously monitor multiple parameters. This study represents critical progress for practical sensing using the BSE scheme.
19 July 2023 in Journal of Microelectromechanical Systems
This work reports a multiple-parameter decoupling (MPD) method based on resonant MEMS sensors subject to blue-sideband excitation (BSE), thus enabling simultaneous separation of the cross-coupled physical quantities, e.g. acceleration and temperature, of a single MEMS sensor. Such a technique exploits the property of the BSE that multiple vibration modes of the resonator can be excited at the same time. The proposed MPD algorithm is applied to two distinct resonant MEMS sensors, i.e. a base-line resonant electrostatic force sensor, and a vacuum-packaged resonant MEMS accelerometer. The target measurand of each type of resonant sensor is enveloped by external temperature changes, but the MPD can successfully decouple the measurand from the temperature changes in a single operation. The cross-sensitivity was suppressed by 31 dB and 35 dB for each device, respectively. The decoupled parameters are consistent with the stand-alone measurements, validating the preliminary functionality of the proposed method. The results confirm the merit of the BSE technique for resonant MEMS sensors, and demonstrate significant potential for in-situ temperature fluctuation suppression in high-precision resonant sensors as well as single-device multiple-parameter monitoring.2023-0079
21 September 2023 in Computer Applications in Engineering Education