The effects of thoracic endovascular repair (TEVAR) on the biomechanical properties of aortic tissue have not been adequately studied. Understanding these features is important for the management of endograft-triggered complications of a biomechanical nature. This study aims to examine how stent-graft implantation affects the elastomechanical behavior of the aorta. Non-pathological human thoracic aortas (n=10) were subjected to long-standing perfusion (8h) within a mock circulation loop under physiological conditions. To quantify compliance and its mismatch in the test periods without and with a stent, the aortic pressure and the proximal cyclic circumferential displacement were measured. After perfusion, biaxial tension tests (stress-stretch) were carried out to examine the stiffness profiles between non-stented and stented tissue, followed by a histological assessment. Experimental evidence shows: (i) a significant reduction in aortic distensibility after TEVAR, indicating aortic stiffening and compliance mismatch, (ii) a stiffer behavior of the stented samples compared to the non-stented samples with an earlier entry into the nonlinear part of the stress-stretch curve and (iii) strut-induced histological remodeling of the aortic wall. The biomechanical and histological comparison of the non-stented and stented aortas provides new insights into the interaction between the stent-graft and the aortic wall. The knowledge gained could refine the stent-graft design to minimize the stent-induced impacts on the aortic wall and the resulting complications. STATEMENT OF SIGNIFICANCE: Stent-related cardiovascular complications occur the moment the stent-graft expands on the human aortic wall. Clinicians base their diagnosis on the anatomical morphology of CT scans while neglecting the endograft-triggered biomechanical events that compromise aortic compliance and wall mechanotransduction. Experimental replication of endovascular repair in cadaver aortas within a mock circulation loop may have a catalytic effect on biomechanical and histological findings without an ethical barrier. Demonstrating interactions between the stent and the wall can help clinicians make a broader diagnosis such as ECG-triggered oversizing and stent-graft characteristics based on patient-specific anatomical location and age. In addition, the results can be used to optimize towards more aortophilic stent grafts.
A hallmark of thoracic aortic aneurysms (TAA) is the degenerative remodeling of aortic wall, which leads to progressive aortic dilatation and resulting in an increased risk for aortic dissection or rupture. Telocytes (TCs), a distinct type of interstitial cells described in many tissues and organs, were recently observed in the aortic wall, and studies showed the potential regulation of smooth muscle cell (SMC) homeostasis by TC-released shed vesicles. The purpose of the present work was to study the functions of TCs in medial degeneration of TAA. During aneurysmal formation an increase of aortic TCs was identified in human surgical specimens of TAA-patients, compared to healthy thoracic aortic (HTA)-tissue. We found the presence of epithelial progenitor cells in the adventitial layer, which showed increased infiltration in TAA samples. For functional analysis, HTA- and TAA-telocytes were isolated, characterized, and compared by their protein levels, mRNA- and miRNA-expression profiles. We detected TC and TC-released exosomes near SMCs. TAA-TC-exosomes showed a significant increase of the SMC-related dedifferentiation markers KLF-4-, VEGF-A-, and PDGF-A-protein levels, as well as miRNA-expression levels of miR-146a, miR-221 and miR-222. SMCs treated with TAA-TC-exosomes developed a dedifferentiation-phenotype. In conclusion, the study shows for the first time that TCs are involved in development of TAA and could play a crucial role in SMC phenotype switching by release of extracellular vesicles.
22 January 2021 in European Journal of Cardio-Thoracic Surgery
: OBJECTIVES: Our goal was to develop a modified frozen elephant trunk (FET) prosthesis with a stented left subclavian artery (LSA) side branch for LSA connection and to perform preclinical testing in a human cadaver model. METHODS: We measured aortic diameters, distance between and diameters of supra-aortic vessels and the distance from the LSA offspring to the level of the left vertebral artery offspring in 70 patients. Based on these measurements, a novel FET prosthesis was developed (Cryolife/Jotec, Hechingen, Germany) featuring a stented side branch for an intrathoracic LSA connection. The feasibility and ease of implantation were tested in 2 human cadaver models at the Anatomical Institute of the Medical University Graz. A covered stent graft (Advanta V12™ by Atrium Medical Corp., Hudson, NH, USA) was used for an LSA extension. RESULTS: Accurate deployment of the novel FET prosthesis with anatomical orientation of the stented side branch towards the LSA ostium followed by consecutive stent graft deployment was feasible in both cases. Proximalizing the distal anastomosis level from zone 3 to zone 1 not only diminished the complexity of the procedure but substantially facilitated the completion of the distal anastomosis. A 2.5-cm long extension stent graft was sufficient to seal to the LSA and to maintain left vertebral artery patency in both cases. CONCLUSIONS: This initial study in human anatomical bodies could demonstrate the feasibility of implanting a newly designed FET prosthesis. This evolution of the FET technique has the potential to substantially ease total aortic arch replacement by proximalization of the distal anastomosis into zone 1 and by shortening spinal and lower body hypothermic circulatory arrest times via a stented side branch to the LSA. This direct connection enables early restoration of systemic perfusion.
The frozen elephant trunk (FET) technique is an established therapeutic option in the treatment of complex aortic diseases. We report our long-term clinical outcomes after FET repair. A total of 187 consecutive patients underwent FET repair at our department between 8/2005 and 3/2023. Indications included acute and chronic aortic dissections and thoracic aneurysms. Endpoints included operative morbidity and mortality, long-term survival, and the need for reinterventions. Operative mortality, spinal cord injury and permanent stroke rates were: 9.6%, 2.7% and 10.2%, respectively. At five years, overall survival was 69.9 ± 3.9% and freedom from aortic-related death was 82.5 ± 3.0%, whereas at ten years, overall survival was 53.0 ± 5.5% and freedom from aortic-related death was 75.8 ± 4.8%. Sixty-one reinterventions on the thoracic aorta were necessary. Freedom from secondary interventions at ten years was 44.7 ± 6.4% overall (63.1 ± 10.0% for acute dissections, 40.8 ± 10.3% for chronic dissections and 28.9 ± 13.1% for aneurysms, respectively). The high reintervention rate for chronic dissections and for aneurysms is related to the pre-existing aortic pathology. Late aortic growth of untreated segments with potentially fatal outcome occurs even after ten years, so careful annual follow-up is mandatory in this patient cohort.
3 June 2024 in European Journal of Cardio-Thoracic Surgery
The aim of this multicentre study was to demonstrate the safety and clinical performance of E-vita OPEN NEO Stent Graft System (Artivion, Inc.) in the treatment of aneurysm or dissection, both acute and chronic, in the ascending aorta, aortic arch and descending thoracic aorta. In this observational study of 12 centres performed in Europe and in Asia patients were enrolled between December 2020 and March 2022. All patients underwent frozen elephant trunk using E-vita OPEN NEO Stent Graft System. Primary end point was the rate of all-cause mortality at 30 days and secondary end points included further clinical and safety data are reported up to 3–6 months postoperatively. A total of 100 patients (66.7% male; mean age, 57.7 years) were enrolled at 12 sites. A total of 99 patients underwent surgery using the E-vita OPEN NEO for acute or subacute type A aortic dissection (n = 37), chronic type A aortic dissection (n = 33) or thoracic aortic aneurysm (n = 29), while 1 patient did not undergo surgery. Device technical success at 24 h was achieved in 97.0%. At discharge, new disabling stroke occurred in 4.4%, while new paraplegia and new paraparesis was reported in 2.2% and 2.2%, respectively. Renal failure requiring permanent (>90 days) dialysis or hemofiltration at discharge was observed in 3.3% of patients. Between discharge and the 3–6 months visit, no patients experienced new disabling stroke, new paraplegia or new paraparesis. The 30-day mortality was 5.1% and the estimated 6-month survival rate was 91.6% (standard deviation: 2.9). Total arch replacement with the E-vita OPEN NEO can be performed with excellent results in both the acute and chronic setting. This indicates that E-vita OPEN NEO can be used safely, including in the setting of acute type A aortic dissection.