Sun Il Kwon

Sun Il Kwon


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2021 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
SKSun Il Kwon
Sun Il Kwon
RORyosuke Ota
Ryosuke Ota
EBEric Berg
Eric Berg
FHFumio Hashimoto
Fumio Hashimoto
KNKyohei Nakajima
Kyohei Nakajima
SCSimon R. Cherry
Simon R. Cherry

2 September 2016 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
SKSun Il Kwon
Sun Il Kwon
AGAlberto Gola
Alberto Gola
AFAlessandro Ferri
Alessandro Ferri
CPClaudio Piemonte
Claudio Piemonte
SCSimon R Cherry
Simon R Cherry
Bismuth germanate (BGO) was a very attractive scintillator in early-generation positron emission tomography (PET) scanners. However, the major disadvantages of BGO are lower light yield and longer rise and decay time compared to currently popular scintillators such as LSO and LYSO. This results in poorer coincidence timing resolution and it has generally been assumed that BGO is not a suitable scintillator for time-of-flight (TOF) PET applications. However, when a 511 keV photon interacts in a scintillator, a number of Cerenkov photons are produced promptly by energetic electrons released by photoelectric or Compton interactions. If these prompt photons can be captured, they could provide a better timing trigger for PET. Since BGO has a high refractive index (increasing the Cerenkov light yield) and excellent optical transparency down to 320 nm (Cerenkov light yield is higher at shorter wavelengths), we hypothesized that the coincidence timing resolution of BGO can be significantly improved by efficient detection of the Cerenkov photons. However, since the number of Cerenkov photons is far less than the number of scintillation photons, and they are more abundant in the UV and blue part of the spectrum, photosensors need to have high UV/blue sensitivity, fast temporal response, and very low noise in order to trigger on the faint Cerenkov signal. In this respect, NUV-HD silicon photomultipliers (SiPMs) (FBK, Trento, Italy) are an excellent fit for our approach. In this study, coincidence events were measured using BGO crystals coupled with NUV-HD SiPMs. The existence and influence of Cerenkov photons on the timing measurements were studied using different configurations to exploit the directionality of the Cerenkov emissions. Coincidence resolving time values (FWHM) of ~270 ps from 2 × 3 × 2 mm 3 BGO crystals and ~560 ps from 3 × 3 × 20 mm 3 BGO crystals were obtained. To our knowledge, these are the best coincidence resolving time values reported for BGO to date. With these values, BGO can be considered as a relevant scintillator for TOF PET scanners, especially if photodetectors with even better near UV/blue response can be developed to further improve the efficiency of Cerenkov light detection.

1 May 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
SKSun Il Kwon
Sun Il Kwon
EREmilie Roncali
Emilie Roncali
AGAlberto Gola
Alberto Gola
GPGiovanni Paternoster
Giovanni Paternoster
CPClaudio Piemonte
Claudio Piemonte
SCSimon R Cherry
Simon R Cherry
The scintillator bismuth germanate (BGO) has attractive properties for positron emission tomography (PET) systems such as high stopping power, high photo-fraction, and relatively low cost. However, its moderate scintillation light yield and slow rise and decay time compared to lutetium (yttrium) oxyorthosilicate (L(Y)SO) results in a degradation of coincidence timing resolution when scintillation photons are used for timing. Recently, it has been reported that the coincidence timing resolution of BGO can be improved by detecting Cerenkov photons, while scintillation photons still provide energy information. However, the measured coincidence timing spectrum showed much longer tails compared to the single Gaussian distribution. Because of this, TOF PET detectors based on BGO will perform worse than the full width at half maximum (FWHM) of the distribution, which is the most common metric for timing resolution, would suggest. From simulation studies, during the first few picoseconds, BGO generates ~16 Cerenkov photons per photoelectric interaction, following a 511 keV gamma ray interaction, while the probability of producing a scintillation photon during the first few picoseconds is very small. Therefore, when we configure a BGO crystal with dual-ended readout, the first arriving photons among the two opposing SiPMs are most likely Cerenkov photons, and by selecting the appropriate SiPM, an improvement in coincidence timing resolution can be achieved. In this study, both ends of a 3 × 3 × 20 mm 3 BGO crystal were coupled to NUV-HD SiPMs. Trigger time differences from the dual-ended readout of BGO were widely distributed due to detecting a mixture of prompt Cerenkov and scintillation photons on both SiPMs. When using trigger times from only a single SiPM, the estimated coincidence timing resolution between two identical BGO detectors was 463 ps FWHM and 1463 ps FWTM. In contrast, when using trigger times from both SiPMs, the estimated coincidence timing resolution was 399 ps FWHM and 936 ps FWTM with no loss of events. Based on a recent report, high-bandwidth amplifiers were implemented and shown to further improve the estimated coincidence timing resolution to 331 ps FWHM and 923 ps FWTM. In summary, the coincidence timing resolution of BGO, most notably the FWTM, was significantly improved using time information from the dual-ended readout.

9 August 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
SGStefan Gundacker
Stefan Gundacker
GBGiacomo Borghi
Giacomo Borghi
SCSimon R Cherry
Simon R Cherry
AGAlberto Gola
Alberto Gola
DLDaehee Lee
Daehee Lee
SKSun Il Kwon
Sun Il Kwon
Objective. Recent SiPM developments and improved front-end electronics have opened new doors in TOF-PET with a focus on prompt photon detection. For instance, the relatively high Cherenkov yield of bismuth-germanate (BGO) upon 511 keV gamma interaction has triggered a lot of interest, especially for its use in total body positron emission tomography (PET) scanners due to the crystal’s relatively low material and production costs. However, the electronic readout and timing optimization of the SiPMs still poses many questions. Lab experiments have shown the prospect of Cherenkov detection, with coincidence time resolutions (CTRs) of 200 ps FWHM achieved with small pixels, but lack system integration due to an unacceptable high power uptake of the used amplifiers. Approach. Following recent studies the most practical circuits with lower power uptake (<30 mW) have been implemented and the CTR performance with BGO of newly developed SiPMs from Fondazione Bruno Kessler tested. These novel SiPMs are optimized for highest single photon time resolution (SPTR). Main results. We achieved a best CTR FWHM of 123 ps for 2 × 2 × 3 mm 3 and 243 ps for 3 × 3 × 20 mm 3 BGO crystals. We further show that with these devices a CTR of 106 ps is possible using commercially available 3 × 3 × 20 mm 3 LYSO:Ce,Mg crystals. To give an insight in the timing properties of these SiPMs, we measured the SPTR with black coated PbF 2 of 2 × 2 × 3 mm 3 size. We confirmed an SPTR of 68 ps FWHM published in literature for standard devices and show that the optimized SiPMs can improve this value to 42 ps. Pushing the SiPM bias and using 1 × 1 mm 2 area devices we measured an SPTR of 28 ps FWHM. Significance. We have shown that advancements in readout electronics and SiPMs can lead to improved CTR with Cherenkov emitting crystals. Enabling time-of-flight with BGO will trigger a high interest for its use in low-cost and total-body PET scanners. Furthermore, owing to the prompt nature of Cherenkov emission, future CTR improvements are conceivable, for which a low-power electronic implementation is indispensable. In an extended discussion we will give a roadmap to best timing with prompt photons.

1 April 2019 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
EREmilie Roncali
Emilie Roncali
SKSun Il Kwon
Sun Il Kwon
SJSebastien Jan
Sebastien Jan
EBEric Berg
Eric Berg
SCSimon R Cherry
Simon R Cherry
Purpose : We are investigating the use of promptly emitted Cerenkov photons to improve scintillation detector timing resolution for time-of-flight (TOF) positron emission tomography (PET). Bismuth germanate (BGO) scintillator was used in most commercial PET scanners until the emergence of lutetium oxyorthosilicate, which allowed for TOF PET by triggering on the fast and bright scintillation signal. Yet BGO is also a candidate to generate fast timing triggers based on Cerenkov light produced in the first few picoseconds following a gamma interaction. Triggering on the Cerenkov light produces excellent timing resolution in BGO but is complicated by the very low number of photons produced. A better understanding of the transport and collection of Cerenkov photons is needed to optimize their use for effective triggering of the detectors. Methods : We simultaneously generated and tracked Cerenkov and scintillation photons with a new model of light transport that we have released in GATE V8.0. This crystal reflectance model was used to study photon detection and timing properties, building realistic waveforms as measured with silicon photomultipliers. Results : We compared the behavior and effect of detecting Cerenkov and scintillation photons at several levels, including detection time stamps, travel time, and coincidence resolving time in 3 × 3 × 20 mm 3 BGO crystals. Simulations showed excellent agreement with experimental results and indicated that Cerenkov photons constitute the majority of the signal rising edge. They are therefore critical to provide early triggering and improved the coincidence timing resolution by 50%. Potential applications : To our knowledge, this is the first complete simulation of the generation, transport, and detection of the combination of Cerenkov and scintillation photons for TOF detectors. This simulation framework will allow for quantitative study of the factors influencing timing resolution, including the photodetector characteristics, and ultimately aid the development of BGO and other Cerenkov-based detectors for TOF PET.

17 March 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
RORyosuke Ota
Ryosuke Ota
KNKyohei Nakajima
Kyohei Nakajima
IOIzumi Ogawa
Izumi Ogawa
YTYoichi Tamagawa
Yoichi Tamagawa
SKSun Il Kwon
Sun Il Kwon
THTomoyuki Hasegawa
Tomoyuki Hasegawa
Achieving direct imaging of the annihilation position of a positron on an event-by-event basis using an ultrafast detector would have a great impact on the field of nuclear medicine. Cherenkov emission is the most attractive physical phenomenon for realizing such an ultrafast timing performance. Moreover, a microchannel-plate photomultiplier tube (MCP-PMT) is one of the most promising photodetectors for fully exploiting the fast timing properties of Cherenkov emission owing to its excellent single photon time resolution of 25 ps full width at half maximum (FWHM). However, as the MCP structure generally contains a lead compound, the gamma rays frequently and directly interact with the MCP, resulting in the degradation of its timing performance and generation of undesirable side peaks in its coincidence timing histogram. To overcome this problem, we have developed a new MCP-PMT based on an MCP consisting of borosilicate glass, thus drastically reducing the probability of the photoelectric effect occurring in the MCP. To evaluate its insensitivity to gamma rays and its timing performance, a coincidence experiment was performed and showed that the probability of direct interactions was reduced by a factor of 3.4. Moreover, a coincidence time resolution of 35.4 ± 0.4 ps FWHM, which is equivalent to a position resolution of 5.31 mm, was obtained without any pulse height/area cut, improving to 28.7 ± 3.0 ps when selecting on the highest amplitude events by careful optimization of the voltage divider circuit of the new MCP-PMT. The timing performance of this new MCP-PMT presents an important step toward making direct imaging possible.