Radiation detectors dedicated to time-of-flight positron emission tomography (PET) have been developed, and coincidence time resolution (CTR) of sub-100 ps full width at half maximum (FWHM) has been achieved by carefully optimizing scintillators and photodetectors. Achieving a CTR of 30 ps FWHM by using a pair of annihilation γ -rays would allow us to directly localize the annihilation point within an accuracy of 4.5 mm. Such direct localization can potentially eliminate the requirement of image reconstruction processes in clinical PET systems, which would have a huge impact on clinical protocols and molecular imaging. To obtain such a high CTR, researchers have investigated the use of prompt emissions such as Cherenkov radiation and hot-intra band luminescence. Although it is still challenging to achieve a CTR of 30 ps FWHM even with a Cherenkov-based detector, the experimentally measured CTR is approaching the goal. In this work, we developed a Cherenkov-radiator-integrated micro-channel plate photomultiplier tube (CRI-MCP-PMT), where there are no optical boundaries between the radiator and photocathode, and its timing performance was investigated. By removing the optical boundaries, reflections are eliminated and transmission to the photocathode is improved, resulting in high timing capability. As a result, a CTR of 30.1 ± 2.4 ps FWHM, which is equivalent to a position resolution of 4.5 ± 0.3 mm along a line of response (LOR), was obtained by using a pair of CRI-MCP-PMTs.
Achieving direct imaging of the annihilation position of a positron on an event-by-event basis using an ultrafast detector would have a great impact on the field of nuclear medicine. Cherenkov emission is the most attractive physical phenomenon for realizing such an ultrafast timing performance. Moreover, a microchannel-plate photomultiplier tube (MCP-PMT) is one of the most promising photodetectors for fully exploiting the fast timing properties of Cherenkov emission owing to its excellent single photon time resolution of 25 ps full width at half maximum (FWHM). However, as the MCP structure generally contains a lead compound, the gamma rays frequently and directly interact with the MCP, resulting in the degradation of its timing performance and generation of undesirable side peaks in its coincidence timing histogram. To overcome this problem, we have developed a new MCP-PMT based on an MCP consisting of borosilicate glass, thus drastically reducing the probability of the photoelectric effect occurring in the MCP. To evaluate its insensitivity to gamma rays and its timing performance, a coincidence experiment was performed and showed that the probability of direct interactions was reduced by a factor of 3.4. Moreover, a coincidence time resolution of 35.4 ± 0.4 ps FWHM, which is equivalent to a position resolution of 5.31 mm, was obtained without any pulse height/area cut, improving to 28.7 ± 3.0 ps when selecting on the highest amplitude events by careful optimization of the voltage divider circuit of the new MCP-PMT. The timing performance of this new MCP-PMT presents an important step toward making direct imaging possible.
Objective. Convolutional neural networks (CNNs) are a strong tool for improving the coincidence time resolution (CTR) of time-of-flight (TOF) positron emission tomography detectors. However, several signal waveforms from multiple source positions are required for CNN training. Furthermore, there is concern that TOF estimation is biased near the edge of the training space, despite the reduced estimation variance (i.e. timing uncertainty). Approach. We propose a simple method for unbiased TOF estimation by combining a conventional leading-edge discriminator (LED) and a CNN that can be trained with waveforms collected from one source position. The proposed method estimates and corrects the time difference error calculated by the LED rather than the absolute time difference. This model can eliminate the TOF estimation bias, as the combination with the LED converts the distribution of the label data from discrete values at each position into a continuous symmetric distribution. Main results. Evaluation results using signal waveforms collected from scintillation detectors show that the proposed method can correctly estimate all source positions without bias from a single source position. Moreover, the proposed method improves the CTR of the conventional LED. Significance. We believe that the improved CTR will not only increase the signal-to-noise ratio but will also contribute significantly to a part of the direct positron emission imaging.