Erkan Bicici

Dr. Erkan Bicici


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Construction and Building Materials
Verified
Journal Article
Closed access
YZYixin Zhang
Yixin Zhang
EBErkan Bicici
Erkan Bicici
HSHalil Sezen
Halil Sezen
SZShansuo Zheng
Shansuo Zheng

1 June 2021 in Journal of Composites for Construction
Verified
Journal Article
Closed access
PDF file
Gao MaGao Ma
Gao Ma
XCXiaohuang Chen
Xiaohuang Chen
EBErkan Bicici
Erkan Bicici
CHChunxu Hou
Chunxu Hou
HSHalil Sezen
Halil Sezen
To investigate the size and slenderness effect on the axial-compressive behavior of basalt fiber–reinforced polymer (BFRP)-confined predamaged concrete, five groups of concrete cylinders with different sizes and slenderness ratios were designed and tested. The cylinders were axially preloaded to three predamage levels, then repaired using BFRP, and reloaded. The results showed that the concrete predamage had an adverse effect on the ultimate strength and initial elastic modulus of BFRP-confined concrete. Except for the smallest specimens affected by the wall effect, the initial analysis found that the ultimate strength of BFRP-confined concrete decreased with an increase in size and slenderness ratio, and the size and slenderness effect decreased with an increase in BFRP confining pressure, while these increased with the severity of concrete predamage. However, there was no obvious size or slenderness effect on the ultimate strain of BFRP-confined concrete. Through multifactorial analysis, it was confirmed that the ultimate strength of BFRP-confined undamaged and predamaged concrete was influenced by the slenderness. Considering the effect of size, slenderness, and predamage, monotonic and cyclic models were developed for BFRP-confined concrete. Finally, a uniaxial material object was added into OpenSees to provide an effective numerical material model for theoretical analyses and engineering applications.

1 August 2020 in Revista de la construcción
Verified
Journal Article
Open access
PDF file
NCNaci Caglar
Naci Caglar
ASAlexander Sichko
Alexander Sichko
Halil SezenHalil Sezen
Halil Sezen
EBErkan Bicici
Erkan Bicici
ADAYDIN DEMIR
AYDIN DEMIR
AFAhmad Farhan Farah
Ahmad Farhan Farah
Retrofit and rebuilding are two potential solutions for reinforced concrete (RC) structures with columns that have insufficient detailing or strength to withstand seismic loads or other extreme events. Demolition and rebuilding can be expensive and time-consuming. Thus, retrofitting and strengthening of columns can be an efficient solution. Jacketing of reinforced concrete columns is one of the common methods for retrofit and rebuilding. For jacketing method, the main concern is the performance loss between new and old concrete due to interface slip. There are three major options to provide a better performance, as surface roughening, dowels, and both. In this study, the methods to provide coworking of new and old concrete are evaluated with respect to four parameters; strength, energy dissipation, stiffness, and displacement ductility. Additionally, a slip coefficient is proposed to model the friction between new and old concrete. The proposed model is applied into OpenSees and a Finite Element (FE) software. The slip coefficient is simulated numerically by a friction coefficient using a tangential contact behavior definition as well. Finally, a slip coefficient is proposed for each method.

8 January 2026 in Structures
Verified
Journal Article
Closed access
EBErkan Bicici
Erkan Bicici
HSHalil Sezen
Halil Sezen

1 January 2025
Verified
Journal Article
Open access
PDF file
EBErkan Bicici
Erkan Bicici
Failure or collapse of the entire structure triggered by a local element-level failure can be defined as progressive collapse. The degradation and loss of the capacity of an element leads to a new load path on the structure, which creates a new load-carrying mechanism. The most common approach is the sudden removal of the column and pushdown analysis. In this study, a new method is proposed to simulate progressive collapse of reinforced concrete structures. The proposed method includes the shear-axial interaction of reinforced concrete columns and consideration of axial shortening of columns due to lateral strength degradation. The proposed method may be applicable for the progressive collapse analysis of a concrete structure under an earthquake. The proposed method is tested in 2D and 3D typical benchmark reinforced concrete frames. The behavior of the frames calculated by the proposed method is compared with the results obtained from pushdown analysis to validate the accuracy of the model. A good agreement is observed between the proposed method and pushdown analysis. The shear-axial interaction method sufficiently covers the behavior of frame analysis with the sudden loss of a column. Thus, the proposed method simulates more realistic failure under cyclic loading, such as earthquakes.

26 December 2023 in Academic Platform Journal of Natural Hazards and Disaster Management
Verified
Journal Article
Closed access
EBErkan Bicici
Erkan Bicici
The locally or entirely collapse of a structure triggered by failure of one or a couple elements can be considered as progressive collapse. New load distribution and additional loads may be created for the remaining elements of the frame. To accurately understand the progressive collapse mechanism, it is needed to accurate estimation of load distribution after failure of an element. The removal of a column and pushdown analysis is a widely used approach to evaluate the progressive collapse mechanism. However, in this study, effect of removal of three different columns on the frame are studied under two conditions; a) removal of column and pushdown analysis, b) loss on the axial capacity of column under cyclic loading. To axial capacity loss of reinforced concrete column, author’s previously developed axial capacity model is employed. A 2D three-story five-bay benchmark frame is analyzed under pushdown and quasi-static cyclic loading. Distribution of loads after failure of a column is investigated under six different scenarios.