Yingchun Peng

Yingchun Peng


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2019 in Applied Optics
Verified
Journal Article
Closed access
PDF file
QWQuan Wen
Quan Wen
HLHongjie Lei
Hongjie Lei
JHJian Huang
Jian Huang
FYFan Yu
Fan Yu
LHLiangkun Huang
Liangkun Huang
ZWZhiyu Wen
Zhiyu Wen
Aiming to implement a low-cost single-photodetector-based NIR micro-spectrometer, we present a novel flame retardant 4 (FR4)-driven micro-grating for spectral dispersion and spatial scanning. It consists of a silicon blazed grating directly bonded onto the FR4 actuator platform and an integrated differential electromagnetic angle sensor. Owing to the better shock and vibration reliability, larger aperture, shorter fabrication cycle, and much lower cost, it may be a potential alternative to conventional silicon microelectromechanical systems scanning micro-gratings. The micro-spectrometer prototype based on this device shows a spectral range of 800–1800 nm, a spectral accuracy of ±1.3  nm, and a 10 nm spectral resolution.

23 October 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
YPYingchun Peng
Yingchun Peng
GWGuoguo Wu
Guoguo Wu
CPChunpeng Pan
Chunpeng Pan
CLCheng Lv
Cheng Lv
TLTianhong Luo
Tianhong Luo
Our previous report based on a 10 g (gravity) silicon-based inertial micro-switch showed that the contact effect between the two electrodes can be improved by squeeze-film damping. As an extended study toward its potential applications, the switch with a large proof mass suspended by four flexible serpentine springs was redesigned to achieve 5 g threshold value and enhanced threshold accuracy. The impact of the squeeze-film damping on the threshold value was theoretically studied. The theoretical results show that the threshold variation from the designed value due to fabrication errors can be reduced by optimizing the device thickness (the thickness of the proof mass and springs) and then establishing a tradeoff between the damping and elastic forces, thus improving the threshold accuracy. The design strategy was verified by FEM (finite-element-method) simulation and an experimental test. The simulation results show that the maximum threshold deviation was only 0.15 g, when the device thickness variation range was 16–24 μm, which is an adequately wide latitude for the current bulk silicon micromachining technology. The measured threshold values were 4.9–5.8 g and the device thicknesses were 18.2–22.5 μm, agreeing well with the simulation results. The measured contact time was 50 μs which is also in good agreement with our previous work.