Our previous report based on a 10 g (gravity) silicon-based inertial micro-switch showed that the contact effect between the two electrodes can be improved by squeeze-film damping. As an extended study toward its potential applications, the switch with a large proof mass suspended by four flexible serpentine springs was redesigned to achieve 5 g threshold value and enhanced threshold accuracy. The impact of the squeeze-film damping on the threshold value was theoretically studied. The theoretical results show that the threshold variation from the designed value due to fabrication errors can be reduced by optimizing the device thickness (the thickness of the proof mass and springs) and then establishing a tradeoff between the damping and elastic forces, thus improving the threshold accuracy. The design strategy was verified by FEM (finite-element-method) simulation and an experimental test. The simulation results show that the maximum threshold deviation was only 0.15 g, when the device thickness variation range was 16–24 μm, which is an adequately wide latitude for the current bulk silicon micromachining technology. The measured threshold values were 4.9–5.8 g and the device thicknesses were 18.2–22.5 μm, agreeing well with the simulation results. The measured contact time was 50 μs which is also in good agreement with our previous work.
Synchronous control is a fundamental and significant problem for controlling a multi-joint robot. In this article, by applying two coupled Rayleigh oscillators as the referred central pattern generator models for the two joints of a two-degrees-of-freedom robot, the central pattern generator–based coupling control method is proposed for controlling the two-degrees-of-freedom robot’s joints. On these bases, the co-simulation model of the two-degrees-of-freedom robot with the proposed central pattern generator–based coupling control method is established via ADAMS and MATLAB/Simulink, and the performance of the central pattern generator–based coupling control method on synchronizing two motions of two-degrees-of-freedom robot’s joints is numerically simulated. Furthermore, the experimental setup of a two-degrees-of-freedom robot is established based on the real-time simulations system via the proposed central pattern generator–based coupling control method. And experiments are carried out on the established setup. Simulations and experimental results show that the phase of the controlled two-degrees-of-freedom robot’s joints is mutual locked to other, and their motion pattern can be adjusted through the coupling parameter in the central pattern generator–based coupling control method. In conclusion, the proposed central pattern generator–based coupling control method can control the two-degrees-of-freedom robot’s joints to produce the coordinated motions and adjust the rhythmic pattern of the two-degrees-of-freedom robot.
Line structured light systems have been widely applied in the measurement of various fields. Calibration has been a hot research topic as a vitally important process of the line structured light system. The accurate calibration directly affects the measurement result of the line structured light system. However, the external environment factors, such as uneven illumination and uncertain light stripe width, can easily lead to an inaccurate extraction of light stripe center, which will affect the accuracy of the calibration. An image analysis-based framework in the calibration process was proposed for the line structure light system in this paper. A three-dimensional (3D) vision model of line structure light system was constructed. An image filtering model was established to equalize the uneven illumination of light stripe image. After segmenting the stripe image, an adaptive window was developed, and the width of the light stripe was estimated by sliding the window over the light stripe image. The light stripe center was calculated using the gray centroid method. The light plane was fitted based on the calibration points coordinates acquired by the camera system. In the measurement experiment of standard gauge block width, the maximum and minimum average deviations of 0.021 pixels and 0.008 pixels and the maximum and minimum absolute deviations of 0.023 pixels and 0.009 pixels could be obtained by using the proposed method, which implies the accuracy of the proposed method.
The biologically-inspired motion control theory was introduced to ameliorate human-robot interaction flexibility and multi-joint autonomy in walking assist. A new type of human-robot interaction (HRI)-based coordination control method which combined a hip CPG (central pattern generator) control, a knee hierarchical impedance control and a hip-knee linkage control was explored. Firstly, the characteristics of CPGs self-oscillation and external communication were utilized to obtain the ideal master/slave hip joint trajectories, and CPG-units symmetrical inhibition were established to maintain anti-phase of the left and right hip joints. Secondly, according to the requirements of gait, a high and low hierarchical impedance control law was designed, and thus the knee joint torques during support stage and swing stage were obtained respectively. Finally, a hip-knee joints linkage mechanism was built to incorporate the hip joint CPG control with the knee-joint impedance control, and thus natural and relevant hip-knee joints trajectory was realized. The stability of the HRI-based coordination control method was researched by using Lyapunov stability theory. Walking experiments were carried out to certificate that the proposed control method was effective in generating nature hip-knee joints trajectory in walking.
Addressing the challenges posed by the limited flexibility and delayed response of conventional rigid-driven rehabilitation robots in complex human-computer interaction environments, a novel approach is proposed: a reconfigurable active variable stiffness principle based on the VSA model. This approach enables the adjustment and adaptation of joint stiffness by modifying the spring preload. It involves the design of a variable stiffness lower extremity exoskeleton for rehabilitation training, integrating pneumatic muscle and magnetorheological brake technologies. Theoretical stiffness models are developed, and stiffness characteristics are thoroughly simulated and analyzed in conjunction with the variable stiffness principle. To enhance the exoskeleton control system's tracking precision, a composite control strategy is formulated, combining virtual force field and impedance control methodologies. Subsequently, the stiffness characteristics and tracking performance of the joint are empirically validated. The research findings demonstrate the efficacy of the active variable stiffness model, augmented by virtual force field adaptive impedance control. Notably, this approach enhances parameter iteration speed, reduces maximum joint tracking errors by 16.634%, and extends the stiffness output range from 13.33 N.m/° to 26.15 N.m/°.