Recent studies have documented Pfhrp2/3 gene deletion globally as one of the biological threats in the fight against malaria. For malaria diagnosis, PfHRP2 based RDTs are most widely used in India, and performance of these RDTs are affected by deleted Pfhrp2/3 gene in Plasmodium falciparum. This study was planned to confirm Pfhrp2/3 gene deletion incidences and genetic variation in PfHRP2-based RDT positive with P.falciparum malaria cases from India. Confirmed positive samples by PfHRP2-based RDTs as P. falciparum (n = 240) from six different endemic regions of India were validated by PCR to assure the actual infection. Two hundred forty samples qualified for DNA intactness by single-copy genes were subjected to amplification for the Pfhrp2/3 gene and its neighbouring gene (downstream and upstream) by PCR genotyping. Genetic variation in samples was analysed post-sequencing using Mega X software. Statistical analysis was performed to validate the genetic variation using Mann-Whitney Test. RDT target region of Pfhrp2 gene (exon2) was found deleted in a single sample with presence of the Pfhrp3 exon2. Complete gene deletion of 4.2% was observed in the Pfhrp3 gene. Partial gene deletion was recorded for both pfhrp2 gene (exon2-0.4%, upstream 25.8% and downstream -9.1%) and Pfhrp3 gene (exon2-18.75%, upstream - 22.08% and downstream 13.3%). Eleven new unique types of amino acid repeat sequence and earlier reported amino acid repeat type was found in the Pfhrp2 gene, prompting high genetic variation. This study suggests that parasites lacking Pfhrp2/3 gene and its neighbouring gene (downstream and upstream) are present in malaria endemic areas of India, resulting in false positive results by RDT. Systematic countrywide monitoring for malaria control and elimination of malaria is warranted in this regard.
Isothermal techniques with lateral flow detection have emerged as a point of care (POC) technique for malaria, a major parasitic disease in tropical countries such as India. Plasmodium falciparum and Plasmodium vivax are the two most prevalent malaria species found in the country. An advanced multiplex loop-mediated isothermal amplification (mLAMP) combined with a lateral flow dipstick (LFD) technique was developed for the swift and accurate detection of P. falciparum and P. vivax, overcoming the challenges of the existing RDTs (rapid diagnostic tests). A single set of LAMP primers with a biotinylated backward inner primer (BIP primer) was used for DNA amplification of both malaria species in a single tube. The amplified DNA was hybridized with fluorescein isothiocyanate (FITC) and digoxigenin-labelled DNA probes, having a complemented sequence for the P. falciparum and P. vivax genomes, respectively. A colour band appeared on two separate LFDs for P. falciparum and P. vivax upon running the hybridized solution over them. In total, 39 clinical samples were collected from ICMR-NIMR, New Delhi. Melting curve analysis, with cross primers for both species, was used to ascertain specificity, and the sensitivity was equated with a polymerase chain reaction (PCR). The results were visualized on the LFD for both species within 60 min. We found 100% sensitivity and specificity, when compared with a traditional PCR. Melting curve analysis of mLAMP revealed the lowest detection limit of 0.15 pg/μL from sample genomic DNA. The mLAMP-LFD assays could be a potential point of care (POC) tool for early diagnosis in non-laboratory conditions, with the convenience of a reduced assay time and the simple interpretation of results.
Complications due to malaria are caused mostly by host immunological responses. Plasmodium falciparum subverts host immunity by various strategies, including modulation in the host immune responses by regulating cytokines. The transcriptional alterations of major cytokines and immunoregulators were analyzed in this study through gene expression profiling in clinically defined subgroups of P. falciparum patients. Malaria patients were included from Dhalai district hospital of Tripura with uncomplicated malaria (UC) and severe malaria (SM) and healthy controls from endemic and non-endemic areas of India. qPCR gene expression analysis was performed for all factors and they were grouped into three clusters based on their altered expressions. The first cluster was downregulated with an increased parasitic burden which included T-BET, GATA3, EOMES, TGF-β, STAT4, STAT6 and cytokines IFN-γ, IL-12, IL-4, IL-5, and IL-13. RANTES, IL-8, CCR8, and CXCR3 were decreased in the SM group. The second cluster was upregulated with severity and included TNF-α, IL-10, IL-1β and IL-7. PD-1 and BCL6 were increased in the SM group. The third cluster comprised of NF-κB and was not altered. The level of perforin was suppressed while GrB expression was elevated in SM. P. falciparum malaria burden is characterized by the modulation of host immunity via compromization of T cell-mediated responses and suppression of innate immune-regulators.
1 May 2024 in The American Journal of Tropical Medicine and Hygiene
: Malaria elimination is one of the top health care priorities in India, necessitating accessible and accurate diagnosis for effective treatment. A malaria slide bank in India is a collection of quality-controlled malaria-positive and -negative slides and is considered a vital asset for quality diagnosis. The collection of blood samples, preparation of blood smears, staining, quality control, molecular characterizations, and slide validation were carried out according to standard operating procedures in accordance with the WHO reference laboratory. The true count and parasite density per microliter were computed in accordance with WHO guidelines. Over 27 months, 48 batches (8,196 slides) were prepared. Overall, the majority of slide batches were Plasmodium vivax (45.9%; 22/48), followed by Plasmodium falciparum (25%; 12/48), malaria-negative infections (25%; 12/48), and mixed infections (4.1%; 2/48). All 48 batches passed internal validation by WHO-certified level-1 microscopists. For a batch, the true count was the median of the validators’ counts (range, 111–280,795 parasites/µL). Except for mixed infections, the PCR results agreed with the verified microscopy results. Malaria slide bank slides would be a valuable tool for quality control, assurance, and microscopist training.
10 January 2022 in The American Journal of Tropical Medicine and Hygiene
Plasmodium vivax malaria elimination requires radical cure with chloroquine/primaquine. However, primaquine causes hemolysis in glucose-6-phosphate dehydrogenase-deficient (G6PDd) individuals. Between February 2016 and July 2017 in Odisha State, India, a prospective, observational, active pharmacovigilance study assessed the hematologic safety of directly observed 25 mg/kg chloroquine over 3 days plus primaquine 0.25 mg/kg/day for 14 days in 100 P. vivax patients (≥ 1 year old) with hemoglobin (Hb) ≥ 7 g/dL. Pretreatment G6PDd screening was not done, but patients were advised on hemolysis signs and symptoms using a visual aid. For evaluable patients, the mean absolute change in Hb between day 0 and day 7 was −0.62 g/dL (95% confidence interval [CI]: −0.93, −0.31) for males (N = 53) versus −0.24 g/dL (95%CI: −0.59, 0.10) for females (N = 45; P = 0.034). Hemoglobin declines ≥ 3 g/dL occurred in 5/99 (5.1%) patients (three males, two females); none had concurrent clinical symptoms of hemolysis. Based on G6PD qualitative testing after study completion, three had a G6PD-normal phenotype, one female was confirmed by genotyping as G6PDd heterozygous, and one male had an unknown phenotype. A G6PDd prevalence survey was conducted between August 2017 and March 2018 in the same region using qualitative G6PD testing, confirmed by genotyping. G6PDd prevalence was 12.0% (14/117) in tribal versus 3.1% (16/509) in nontribal populations, with G6PD Orissa identified in 29/30 (96.7%) of G6PDd samples. Following chloroquine/primaquine, notable Hb declines were observed in this population that were not recognized by patients based on clinical signs and symptoms.
13 February 2024 in The American Journal of Tropical Medicine and Hygiene
Since 2010, malaria rapid diagnostic tests (RDTs) are widely used to detect malaria. The Indian Council of Medical Research–National Institute of Malaria Research performed lot testing (LT) according to WHO procedures since 2016. Lot testing is performed to evaluate the lot-to-lot variation in performance of malaria RDTs. Four sets of positive quality control (QC) panels for P. falciparum (Pf) and P. vivax (Pv) and 10 negative panels tested RDTs. RDTs were reported as pass, failed, or deferred on the basis of WHO criteria. In the past 5 years, 275 lots containing 15,488 RDT kits for malaria diagnosis were subjected to LT. The monovalent RDTs (n = 1,216), based on either Pf histidine rich protein 2 (HRP2) or Pan-Plasmodium lactate dehydrogenase (Pan-pLDH) antigens, showed 90.4% sensitivity and 100% specificity, whereas RDTs based on HRP2 + Pan-pLDH or HRP2 + pLDH (n = 13,924) had sensitivity 95.6% and specificity 99.5%, respectively. RDTs based on PfHRP2 + Pv-pLDH + Pan-pLDH (n = 348) had 100% sensitivity and specificity. In a comparison between HRP2 + pLDH or HRP2 + Pan-pLDH to HRP2 + pLDH + Pan-pLDH RDTs, it was found that the sensitivity of PfHRP2 with Pan-pLDH RDTs (n = 2,382) was only 83%. Of the 275 lots analyzed, 15 lots of PfHRP2 with Pan-pLDH were deferred. The QC panel for Pf revealed a faint Pan band in the tested lots, which is a cause for concern. The results of deferred lots were reported to concerned government agencies. Quality-compromised RDTs may lead to an incorrect diagnosis. It is critical to have a QC system in place for effective malaria management.