A high-intensity pulsed magnetic field generator, as a high-power pulsed current generator with inductive loads, can be used in transcranial magnetic stimulation, tumor therapy, and so on. This article presents a new type of pulse generator called the Marx-based modular energy-saving pulse generator (MEPG) that can improve the output performance of conventional pulsed magnetic field generators in the biomedical field. The MEPG includes a front-end energy-feeding circuit and a series of discharging modules at different levels. It can regulate the current of inductive coils, which in turn controls the magnetic field output from the coils. The MEPG incorporates a commutator switch and energy-feeding diode in the front-end circuit, facilitating the feedback of load energy to capacitors at all levels. The MEPG offers flexible adjustment of the output current change rate by controlling the switching sequence of the discharge modules. Moreover, the amplitude of the output current can be fine-tuned by adjusting the switching on time or capacitor voltages at different levels. The converter switch’s opening and closing at the discharge end corresponds to the two distinct output modes: exponential wave and triangular wave pulsed current. To assess the MEPG’s output performance and energy recovery efficiency, a three-stage MEPG system was constructed. The coil was subjected to pulse currents of different amplitudes and pulse widths in both simulations and measurements, revealing the platform’s excellent energy recovery efficiency. Finally, we demonstrated that the MEPG possesses a versatile output functionality by outputting a set of customized pulse current waveforms in the coil.
19 March 2024 in IEEE Transactions on Power Electronics
Insulation power supply (IPS) for multiple switches is a key issue for solid-state pulse generators (SSPG). The existing parallel structure for IPS is short of insulation similarity, which results in low insulation utilization ratio (IUR) and limited adjustability. Here we propose a power supply chain (PSC) with series insulation structure. The insulation circumstance of PSC maintains the same for each stage, which increases the minimum IUR to almost 90%, compared to the existing parallel structures. The proposed PSC requires purely diodes, capacitors, and inductors to achieve IPS for switches, thus avoiding the customized cost and enhancing insulation adjustability. After analyzing the working principle of PSC, we evaluate the performance of PSC from the perspective of power supply and insulation. Finally, an 8-staged Marx SSPG prototype is developed to examine the compatibility of PSC and the protection circuit for PSC is implemented. The withstand voltage of PSC can be easily adjusted within 14 kV according to the number of diodes. The PSC does not require external control signals and does not interfere with gate driving synchronization or load waveforms, which offers a new solution of IPS for compact Marx generators designed at nanosecond scale.
As an emerging technology in liquid inactivation, one of the main challenges of pulsed electric fields (PEFs) inactivation lies in quantitatively describing and predicting its lethality to microorganisms. However, due to its cross-scaled complexity and the consequent numerous regulatory factors, there is currently still no unified framework to understand the PEF dose–response relationship and the population dynamics theoretically. In this study, a simple yet powerful model from multiscale coarse-graining method is proposed to simulate the bacterial inactivation in suspensions during PEF processing. The complex dose–response effects at the macroscale are successfully reconstructed from simple evolution rules and several coarse-graining parameters, while considering the damage and death of a single bacterium at the microscale. Our model uncovers the seemingly chaotic and even controversial dose–response relationship of PEF in literatures and systematically explores the regulatory effect of experimental parameters in a unified framework. One of the interesting findings is that PEF with shorter pulsed width enhances lethality and reduces the minimal inhibitory time at a constant energy output per pulse, owing to the phase transitions in three bacterial population dynamics (Bistability mode, Avalanche mode, and Hybrid mode). Our study provides a new insight for numerically modeling PEF lethality in liquid inactivation and could serve as a guide for dosage management in practical applications.
In the irreversible electroporation (IRE) therapy, the absorbed energy is normally characterized as the applied dose and assumed to be distributed in the homogeneous dielectric. By employing statistical analyses, we have studied the absorbed energy distribution in the porous multicellular dielectric, with the geometric patterns randomly generated from the following statistical quantities: system size, cell size, cell concentration, and cell flattening ratio. Parametric formulas regarding the mean and standard deviation of the absorbed energy are obtained through numerical simulations and iterative fitting. Our statistical results reveal that the mean value of absorbed energy with cell concentration exhibits a “conductance” to “resistance” transition, similar to the percolation of two-phase materials, and the direction of the transition flips as cell diameter increases. The standard deviation of energy, however, follows a bell-shaped curve under varied concentration, indicating a shift in energy distribution from an “aggregation” to a “dispersion” state. Based on the parametric formulation, we quantitatively explore the critical threshold of the transition, as well as the general scaling laws of the geometric variables on the mean and standard deviation of the absorbed energy. Our work could help to quantitatively explain the lethality variation in IRE ablation targeting monolayer cell collectives with different geometrical characteristics.
Numerical models evaluating macroscopic pulsed electric field (PEF) efficacy typically neglect multicellular heterogeneity and assume homogeneous absorbed energy to reduce computational costs. In this Letter, through theoretical analyses from maximum information entropy methods and finite-element simulations of a realistic millimeter-scale monolayer (1393 cells in a 1 mm2 square target), we demonstrate that cellular absorbed energy universally follows a gamma distribution in response to a single pulse, remaining invariant across pulsed types, cell types, and observation scales. We propose a dimensionless heterogeneity metric h (0–1) derived from gamma distribution, to quantify local fluctuations of absorbed energy. Results show h exhibits a hyperbolic tangent dependence on the pulsed width, independent of the field strength. In vitro experiments confirm that the dimensionless h also critically governs PEF efficacy: Reduced h exponentially enhances the response rate of high-dose phase in the survival curves. Real-time fluorescence damage kinetics (169 cells) further validate the gamma-distributed energy pattern. This work uncovers spatial heterogeneity as an essential predictor for PEF efficacy, which advances the resolution setting of theoretical models for PEF efficacy prediction.
From the microscopic electroporation to the irregular distribution of cell populations, the inactivation efficacy of pulsed electric fields (PEFs) from in vitro experiments has lacked a unified physical model due to its cross-scale complexity. Inspired by a coarse-grained approach from the percolation theory, the inactivation process is simulated from a simple yet robust lattice model, where the spatiotemporal heterogeneity of the collective structure and the stochastic PEF strike are portrayed as random matrices, while also accounting for the rules of single-cell electroporation and subsequent death. Beyond successfully simulating the inactivation of monolayer adherent cells and suspended cells, which are in good agreement with in vitro results, our model reveals that (1) macroscopically three-staged inactivation pattern originates from the “accelerate–uniform–decelerate” transition of inactivation velocity, and (2) the inactivation patterns obey a universal scaling law under varied field strength, which is not satisfied under varied pulsed widths. The simulation not only sheds light on the PEF inactivation of the macroscopic cell collectives but also provides a simple and generalized numerical method for predicting PEF efficacy in experiments or engineering.