ABDULLAH ALRASHIDI

ABDULLAH ALRASHIDI


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2026 in Energies
Verified
Journal Article
Open access
PDF file
AAABDULLAH ALRASHIDI
ABDULLAH ALRASHIDI
NENora Elayaat
Nora Elayaat
AEAdel A. Abou El-Ela
Adel A. Abou El-Ela
Ashraf Ahmed FahmyAshraf Ahmed Fahmy
Ashraf Ahmed Fahmy
IIIsmail Mohammed Hafez Ismail
Ismail Mohammed Hafez Ismail
ASabdel azim mohamed Salem
abdel azim mohamed Salem
The fast adoption of electric vehicles (EVs) and the integration of renewable distributed generators (DGs) provide significant operational issues for radial distribution networks (RDNs), notably in terms of power losses, voltage variations, and system stability. This paper investigates the optimal placement and sizing of EV charging stations (EVCSs) and DGs under varying EV hosting factors (EV-HFs). An impedance matrix-based load flow method is developed, and a derived analytical formula for power loss calculation is proposed to improve computational efficiency. A weighted multi-objective function is developed to reduce active power losses and voltage variations while optimizing the voltage stability index and the yearly cost savings from energy loss. The optimization is performed using a deterministic heuristic procedure that incrementally adjusts the location and size of EVCSs and DGs until no further improvement in the fitness function is achieved. This stepwise approach provides fast convergence with low computational effort compared to population-based metaheuristics. The methodology is used on the IEEE 33-bus system under different loading conditions and EV-HFs. The results reveal that for 40% and 60% EV-HFs, active power losses decreased by about 57% compared with the basic case, while the minimum bus voltage improved from 0.9148 pu to 0.9654 pu and 0.9641 pu. The economic analysis demonstrates annual savings of up to USD 473,550, with a payback period between 7 and 8 years. These findings emphasize the need of integrated EVCS and DG planning in improving future distribution systems’ technical and economic performance.

10 July 2026 in Energies
Verified
Journal Article
Open access
PDF file
AAABDULLAH ALRASHIDI
ABDULLAH ALRASHIDI
Ashraf Ahmed FahmyAshraf Ahmed Fahmy
Ashraf Ahmed Fahmy
OSOmar Saif
Omar Saif
MKMohamed Kassem
Mohamed Kassem
AEAdel Abdel monem Elsamahy
Adel Abdel monem Elsamahy
ASabdel azim mohamed Salem
abdel azim mohamed Salem
In order to improve the electrical grid flexibility and efficiency, distributed energy resources (DERs), capacitor banks (CBs), and electric vehicle charging stations (EVCSs) are being integrated into active power distribution networks. However, radial distribution networks have large electrical losses from unidirectional power flow and growing EV penetration, as well as voltage drops and power flow exceeding the thermal capacity limit of some distribution branches. This study is based on the Classification Global Optimization (CGO) approach to include EVCS’s under different hosting factors (30%, 40%, and 50%). The applied CGO framework uses a deterministic global function that includes minimization of electrical losses, reducing the voltage deviation index, increasing the cost of saved energy due to losses and decreasing the annual amount of CO2 emission, this done for the simultaneous placement and sizing of EVCSs, DGs, and CBs after classifying the network buses according to voltage sensitivity and power consumption. Active power loss reductions of up to 94.75% and 98.061% with combined integration are demonstrated by validation on IEEE 33-bus and 69-bus systems, while computational efficiency (simulation times < 5 s) is maintained. This enhanced technique offers a scalable solution for contemporary active distribution networks and directly helps Sustainable Development Goals (SDGs) 7, 9, 11, and 13 by improving grid performance with high EV adoption.

28 October 2026 in Energies
Verified
Journal Article
Open access
PDF file
AAABDULLAH ALRASHIDI
ABDULLAH ALRASHIDI
Ashraf Ahmed FahmyAshraf Ahmed Fahmy
Ashraf Ahmed Fahmy
AAAbdelmenem Abobghala
Abdelmenem Abobghala
This study examines the economic effect of EV-supported export in a residential PV–battery–EV scheduling model using one prepared House1 dataset from 13 June to 2 October 2014. Corrected V2H and export-enabled V2G share cost-minus-revenue accounting and mobility inputs. Capping the stationary-battery reserve target at its 3 kWh usable energy band resolves the original reserve/SOC contradiction and yields valid solutions for all 90 selected days. Without an EV terminal condition, V2G incurs lower costs on 90/90 days, with mean savings of £0.501677/day. Actual re-optimisation with the final EV energy constrained to be at least equal to the initial energy reduces mean savings to £0.012216/day, with 45 lower-cost days and 45 ties within £0.00001. Symmetric post-optimisation restoration accounting instead gives mean savings of −£0.619249/day under both flat off-peak pricing and the specified next-day EV-only charging schedule. Baseline re-optimised export-value onset also shifts upward when terminal energy is constrained. These results distinguish the short-horizon export-revenue mechanism from the value available without net EV depletion. They do not establish full-system cyclic operation, annual investment profitability, or distribution-network feasibility.