The fast adoption of electric vehicles (EVs) and the integration of renewable distributed generators (DGs) provide significant operational issues for radial distribution networks (RDNs), notably in terms of power losses, voltage variations, and system stability. This paper investigates the optimal placement and sizing of EV charging stations (EVCSs) and DGs under varying EV hosting factors (EV-HFs). An impedance matrix-based load flow method is developed, and a derived analytical formula for power loss calculation is proposed to improve computational efficiency. A weighted multi-objective function is developed to reduce active power losses and voltage variations while optimizing the voltage stability index and the yearly cost savings from energy loss. The optimization is performed using a deterministic heuristic procedure that incrementally adjusts the location and size of EVCSs and DGs until no further improvement in the fitness function is achieved. This stepwise approach provides fast convergence with low computational effort compared to population-based metaheuristics. The methodology is used on the IEEE 33-bus system under different loading conditions and EV-HFs. The results reveal that for 40% and 60% EV-HFs, active power losses decreased by about 57% compared with the basic case, while the minimum bus voltage improved from 0.9148 pu to 0.9654 pu and 0.9641 pu. The economic analysis demonstrates annual savings of up to USD 473,550, with a payback period between 7 and 8 years. These findings emphasize the need of integrated EVCS and DG planning in improving future distribution systems’ technical and economic performance.
The contributions in this paper consist of two techniques for power flow analysis and optimization algorithm to optimal integration of distributed generation (DG) sources in radial distribution network (RDN). The 1st technique depends on a mathematical representation to create the bus impedance matrix [Zbus] based on the RDN configuration. The 2nd technique is the Bus-Grouping Optimization Algorithm for any RDN (BGOARDNs) for reducing active and reactive power losses, improving the RDN voltage profile, minimizing the voltage deviation index (VDI) and reducing the annual cost of energy losses through optimal DGs location and sizing. The applicability and effectiveness of the new approach has been verified on the IEEE 33-bus and IEEE 69-bus RDN. It has been observed that the proposed technique method resulted in further improvement in both reducing annual energy losses and saving costs over recent optimization techniques. In the IEEE 33-bus test system, the reduction percentage in active and reactive losses are found to be 65.5% and 65.8% respectively with annual energy cost saving decrement is 65.505%. While in the IEEE 69-bus system, the reduction percentage in active and reactive losses are found to be 69.13% and 65.78% respectively with annual energy cost saving decrement is 69.134%. So, the results of BGOARDNs are better than other techniques.
The main objective of this paper is to enhance the performance of radial distribution networks (RDNs) by developing a new optimization technique integrated with an efficient load flow analysis for the optimal placement and sizing of shunt capacitor banks (SCBs). The key feature of the proposed method lies in the development of an innovative branch-bus incidence matrix (C-Matrix), which enables fast and accurate load flow computation with reduced computational complexity, combined with a mathematical programming-based optimization approach. The enhancement is achieved through power losses reduction, minimization of the annual energy losses cost, network voltage profile improvement, and enhancement of the power factor at the slack bus bar. The proposed technique has been implemented on IEEE 33-bus and IEEE 69-bus RDNs. The results demonstrate that the proposed approach consistently outperforms existing techniques while maintaining high effectiveness. The proposed method achieves a reduction in apparent power losses of 34.61% with annual savings of 11,816 USD and approximate unity power factor (0.9971 lag) at the slack bus bar for the IEEE 33-bus system, while for the IEEE 69-bus system, it achieves a loss reduction of 35.25% with annual savings of 12,857 USD at operating power factor of 0.9917 lag. In addition, a sensitivity analysis under ±20% load variation is conducted to evaluate the robustness of the proposed method. and reliability assessment of IEEE 33-bus RDN is presented which demonstrate by calculation of reliability indices, that RDN is more reliable.
In order to improve the electrical grid flexibility and efficiency, distributed energy resources (DERs), capacitor banks (CBs), and electric vehicle charging stations (EVCSs) are being integrated into active power distribution networks. However, radial distribution networks have large electrical losses from unidirectional power flow and growing EV penetration, as well as voltage drops and power flow exceeding the thermal capacity limit of some distribution branches. This study is based on the Classification Global Optimization (CGO) approach to include EVCS’s under different hosting factors (30%, 40%, and 50%). The applied CGO framework uses a deterministic global function that includes minimization of electrical losses, reducing the voltage deviation index, increasing the cost of saved energy due to losses and decreasing the annual amount of CO2 emission, this done for the simultaneous placement and sizing of EVCSs, DGs, and CBs after classifying the network buses according to voltage sensitivity and power consumption. Active power loss reductions of up to 94.75% and 98.061% with combined integration are demonstrated by validation on IEEE 33-bus and 69-bus systems, while computational efficiency (simulation times < 5 s) is maintained. This enhanced technique offers a scalable solution for contemporary active distribution networks and directly helps Sustainable Development Goals (SDGs) 7, 9, 11, and 13 by improving grid performance with high EV adoption.
1 July 2024 in International Journal of Engineering and Applied Sciences-October 6 University
This paper addressed the analysis, and control for tracking the active power flow (APF) from the synchronous generator (SG). The proposed control relies on the real concept of interaction between (active/reactive) and (governor/exciter voltage). The proposed system is tested by disturbance in active load by increasing or decreasing in 0.1pu. To address this disturbance, traditional controllers such as PID may not suffice for optimal performance. Thus, the Self-Tuning Controller (FST) emerges as a promising solution for PID controllers. Utilizing an Ant Colony Optimization (ACO), PID parameters can be effectively tuned. As a result, two control units of the Self-Tuning PID Controller (OFSTPID) are employed for active and reactive power control loops. This approach enhances active Power Filter (APF) satisfaction while meeting the constant demand for reactive power, thereby enhancing the reliability and quality of the power system. Comparative analysis against relevant literature demonstrates that this methodology leads to improved load frequency Control (LFC) performance and effective compensation for reactive power.
1 January 2025 in International Journal of Engineering and Applied Sciences-October 6 University
The work is based on improving the line regulation and minimizing the THD for the inverter voltage at the connected bus to the microgrid (MG). These objectives have been verified in this study under operating conditions with different types of loads disturbances. The control technique for THD minimization and voltage regulation enhancement is obtained using the tripled actions controller (TAC). This controller combines a PR (Proportional Resonant) controller with SHC (Secondary/Secondary Hybrid Control) and introduces a third controller for the PWM of the voltage obtained from the inverter. Voltage regulation is adjusted applying the FOPID controller, so the bus voltage and the operating frequency will be restored at their rated values. To verify the optimization for this objectives, the study employed PSO method to find the optimum solution. Comparison is done with previous published work, which illustrated that the proposed system outperformed the others with respect to voltage waveform, frequency deviation, and THD. Also, the developed control technique verifies improved power quality issues (PQ) and increased the reliability of power system when supplying different load types.