Quantitative assessment is crucial for the evaluation of human postural balance. The force plate system is the key quantitative balance assessment method. The purpose of this study is to review the important concepts in balance assessment and analyze the experimental conditions, parameter variables, and application scope based on force plate technology. As there is a wide range of balance assessment tests and a variety of commercial force plate systems to choose from, there is room for further improvement of the test details and evaluation variables of the balance assessment. The recommendations presented in this article are the foundation and key part of the postural balance assessment; these recommendations focus on the type of force plate, the subject’s foot posture, and the choice of assessment variables, which further enriches the content of posturography. In order to promote a more reasonable balance assessment method based on force plates, further methodological research and a stronger consensus are still needed.
A Relative Positions-Constrained pattern Matching (RPCM) method for underwater gravity-aided inertial navigation is presented in this paper. In this method the gravity patterns are constructed based on the relative positions of points in a trajectory, which are calculated by Inertial Navigation System (INS) indications. In these patterns the accumulated errors of INS indicated positions are cancelled and removed. Thus the new constructed gravity patterns are more accurate and reliable while the process of matching can be constrained, and the probability of mismatching also can be reduced. Two gravity anomaly maps in the South China Sea were chosen to construct a simulation test. Simulation results show that with this RPCM method, the shape of the trajectory in gravity-aided navigation is not as restricted as that in traditional Terrain Contour Matching (TERCOM) algorithms. Moreover, the performance included matching success rates and position accuracies are highly improved in the RPCM method, especially for the trajectories that are not in straight lines. Thus the proposed method is effective and suitable for practical navigation.
A novel elastic body design idea of six-axis wrist force sensor with a floating beam was raised based on the analysis of the robot six-axis wrist force sensor with a floating beam. The design ideas improve the sensor’s dynamic performance significantly, while not reducing its sensitivity. First, the design ideas were described in detail, which were analyzed by mechanical modeling and were verified by finite element analysis. Second, the static simulation analysis of the novel elastomer of sensor was carried out. According to the strain distribution performance, the position of the strain gauges pasted and the connection mode of the full-bridge circuits were decided, which can achieve theoretical decoupling. Finally, the comparison between the static and dynamic performance of the novel sensor and the original sensor with floating beams was done. The results show that the static and dynamic performance of the novel six-axis wrist sensor are all better than the original sensor.
1 July 2021 in Biomedical Signal Processing and Control
BACKGROUND: Many countries, including Japan, Italy, and China are experiencing demographic shifts as their populations age. Some basic activities of daily living (ADLs) are difficult for elderly people to complete independently due to declines in motor function. OBJECTIVE: In this paper, a 6-DOF wearable cable-driven upper limb exoskeleton (CABexo) based on epicyclic gear trains structure is proposed. METHODS: The main structure of the exoskeleton system is composed of three epicyclic gear train sections. This new exoskeleton has a parallel mechanical structure to the traditional serial structure, but is stiffer and has a stronger carrying capacity. The traditional gear transmission structure is replaced with a cable transmission system, which is quieter, and has higher accuracy and smoother transmission. RESULTS AND CONCLUSIONS: The static workspace of the exoskeleton is large enough to meet the demand of assisting aged and disabled individuals in completing most of their activities of daily living (ADLs).
21 May 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
To facilitate stretch reflex onset (SRO) detection and improve accuracy and reliability of spasticity assessment in clinical settings, a new method to measure dynamic stretch reflex threshold (DSRT) based on Hilbert-Huang transform marginal spectrum entropy (HMSEN) of surface electromyography (sEMG) signals and a portable system to quantify Modified Ashworth Scale (MAS) for spasticity assessment were developed. The sEMG signals were divided into frames using a fixed-length sliding window, and the HMSEN of each frame was calculated. An adaptive threshold was set to measure the DSRT. The HMSEN based method can quantify muscle activity through time-frequency and nonlinear dynamics analysis, therefore providing deeper insight about the spastic muscle mechanisms during stretching and a reliable SRO detection method. Experimental results revealed that the HMSEN based method could reliably detect the SRO and measure the DSRT (recognition rate: 95.45%), and could achieve improved performance over the time-domain based method. There was a strong correlation (r = -0.824 to -0.900) between the MAS scores and the DSRT index, and the test-retest reliability was high. Additionally, limitations of the MAS were analyzed. This study indicates that the presented framework can provide a promising tool to measure DSRT and a clinical quantitative approach for spasticity assessment.