The energy sector is one of the largest consumers of water in Europe. As water scarcity has a severe impact on nature and human health, energy related water consumption, similar as for CO2 emissions, should be included in an environmental assessment. This study investigates the indirect water usage of households through their energy consumption based on a case study for two European countries, Germany and Spain. We calculate the water consumption of several thousand individual residential households based on their electricity consumption and the water intensity of the electric grid in an hourly resolution. Additionally, we investigate the effect of residential photovoltaic and battery electric storage systems on the water consumption and contrast potential optimization strategies towards high self-consumption and water consumption minimization. Our results show that the introduction of a small 0.89 kWp solar system can already reduce indirect water consumption by on average 20 % while a battery and solar photovoltaic system optimized for minimal water consumption achieves a mean reduction of over 40 % in Spain and 25 % in Germany.
The importance of e-learning in modern education systems is increasing, and Server-Side Rendering (SSR) is making a comeback as a popular technique for building websites with dynamic content. This paper examines a real-world e-learning platform utilizing SSR and assesses its performance and environmental impact. An initial analysis of the platform’s usage was conducted to replicate a realistic workload during which we captured realistic user behavior. Since existing load-generation tools do not support all the requirements of modern websites, we developed a custom load-generation tool built on top of established open-source tools. We use our load-generation tool to emulate virtual users, using captured user behavior as a basis. The load generator we developed is very low-maintenance and allows developers to easily test different configurations of a hybrid website without having to adapt the load generator. Therefore, thanks to our flexible load generator, we were able to measure the resources and energy consumption of the real-world e-learning platform under varying virtual user loads in different configurations. The results showed that using a caching mechanism significantly lowered system load compared to a system without caching. Regardless of whether caching was enabled, external network traffic remained nearly identical as all required resources (database, static files, etc.) were hosted on the system. Energy consumption was lower with the cache enabled, aligning with other system resource usage patterns. Specifically, our system would produce 0.161t $$\hbox {CO}_2$$ emissions at idle in a year. Under permanent load with 600 concurrent users, the system would produce 0.192t $$\hbox {CO}_2$$ with caching enabled and 0.203t $$\hbox {CO}_2$$ without caching.
To match the fluctuating renewable energy generation with varying industrial process steam demand, electric heat storage is a viable solution for energy transformation. However, the adoption of this technology by companies hinges on its economic feasibility. Proponents often argue that leveraging spot market electricity prices provides a competitive edge over conventional energy systems without storage. However, additional factors, such as grid fees, levies and taxes can substantially inflate storage charging costs. This study investigates the integration of an electric latent heat storage for process steam within a conventional natural gas boiler system in a paper manufacturing case study under German industrial electricity price regulation to evaluate the effects of electricity prices alongside various operational energy cost factors and rebates through a mixed-integer linear program. Three storage sizes (1 MWh, 100 MWh, 100 GWh) and four electricity procurement configurations (status quo, optimized fixed-price contract, day-ahead only, and a mixed fixed/day-ahead strategy) are analysed. For 100 MWh, the mixed strategy cuts energy costs by about 10% versus day-ahead pricing and around 13.5% versus the status quo contract, lowering the specific electricity price from 6.2 to 5.3 ct/kWh, while emissions range from the slight increases to 23% reductions when grid fees are removed.
Large-scale battery-supported charging station clusters, often referred to as charging hubs, have emerged as a promising solution to meet the growing demand for electric vehicle fast charging. Integrating stationary energy storage systems enables these hubs to mitigate peak power demand and reduce the strain on the local power grid. However, designing and operating such systems remains challenging, as it requires coordinated decisions on battery configuration and control strategies to ensure reliable and cost-effective operation. This work develops a modular simulation framework that enables flexible modeling of charging hubs through extensive parameterization, including adjustments to the number of charging units, the maximum grid power, the buffer storage capacities, and the control strategy.We validate the framework based on real-world data from Audi charging hubs and conduct a case study showing that a cost-optimal charging strategy can achieve cost savings of up to 70 % compared to immediate charging, while an emission-optimal strategy can save up to 17.5 % in CO2 emissions. However, both types of savings reduce significantly with increased charging demand at the charging hub.We demonstrate the framework’s ability to inform planning decisions by identifying the maximum grid power as the limiting factor in supplying even higher charging demands through a series of scenario evaluations.