Dimitrios Mathioulakis

Prof. Dimitrios Mathioulakis

1. School of Mechanical Engineering, National Technical University of Athens, 15780 Athens, Greece
+2

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2010 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
CSCh. Stamatopoulos
Ch. Stamatopoulos
DMDimitrios Mathioulakis
Dimitrios Mathioulakis
YPY. Papaharilaou
Y. Papaharilaou
AKA. Katsamouris
A. Katsamouris

1 August 2017 in Journal of Energy Engineering
Verified
Journal Article
Closed access
DYD. Yiasemides
D. Yiasemides
AAAn. Argyris
An. Argyris
DMDimitrios Mathioulakis
Dimitrios Mathioulakis
The flow through a collapsible thin-walled tube established by gravity is experimentally studied by performing two-dimensional particle image velocimetry (2D PIV) velocity measurements. Two series of experiments are performed during which the flow rate and the inlet tube pressure are kept constant but the outlet pressure is varied. In the first experiment, the velocity field is examined in a plane perpendicular to the plane of tube collapse, when the tube is in a state of weak nonperiodic tube oscillations, focusing on its two-lobe-shaped diffuser formed downstream of the tube midlength. It is verified that when the tube diffuser angle exceeds 20° from a lowering of the transmural pressure, the flow separates alternatively from the opposite walls of the tube constituting a probable triggering mechanism for the initiation of tube periodic oscillations. In the second series of experiments, the velocity field is measured in the plane of the tube collapse when the tube is in a state of periodic self-oscillation. Using the tube outlet pressure as triggering signal, phase-locked PIV measurements are performed revealing the flow evolution within a period. The two-lobed shape of the tube neck cross section oscillating streamwise for a distance of 10% of the unsupported length of the tube is verified through velocity profiles, which show two maxima off axis. Between these two maxima, which are four times the inlet bulk velocity, the flow decelerates when the tube outlet pressure is reduced in each half period, while at the same time the opposite walls of the tube approach each other. In the second half of the period during which the tube expands, negative flow appears near the tube outlet, while the velocity and the width of the two jets increase. The amplitude of the central axial velocity fluctuations is enhanced streamwise, reaching a fivefold increase compared to the inlet, especially close to the tube exit, where the tube deformation is significant.

1 April 2019 in Meccanica
Verified
Journal Article
Closed access
PDF file
SSS. Stelios
S. Stelios
SQS. Qin
S. Qin
FSF. Shan
F. Shan
DMDimitrios Mathioulakis
Dimitrios Mathioulakis

11 April 2022 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
Christos ManopoulosChristos Manopoulos
Christos Manopoulos
ATAchilleas Tsoukalis
Achilleas Tsoukalis
DMDimitrios Mathioulakis
Dimitrios Mathioulakis
A drug infusion peristaltic pump is experimentally studied, examining its performance for three flexible tubes, two cylindrical, and an innovative one of lenticular cross-section with an inflated part. Using water as flowing medium, the pump outlet flow rates were measured at nine phases of the semi-period, based on phase-locked 2D-PIV data. The roller disengagement phase showed to cause a reduction of the outlet flow rate, and in a lesser degree, the engagement phase. Flow acceleration at the pump outlet occurred when only one roller was squeezing the tube. The gauge pressure waveforms at the pump inlet and outlet although noisy had a phase lead with respect to the flow rate. According to the pump motor current waveform, the work of the forces necessary for the tube deformation was about 10 times higher than that of the fluid viscous and inertial forces. Among the three examined flexible tubes, the pump performance was the best when the lenticular tube was used, presenting the highest volumetric efficiency and the smallest outlet flow rate pulsations, pressure amplitudes, and energy consumption. The high pump performance is attributed to the innovative inflated part of the lenticular tube, its cross-sectional shape and its higher compliance compared to the other tubes.

31 January 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
PSPlaton Sarantides
Platon Sarantides
ARAnastasios Raptis
Anastasios Raptis
DMDimitrios Mathioulakis
Dimitrios Mathioulakis
Konstantinos G MoulakakisKonstantinos G Moulakakis
Konstantinos G Moulakakis
JKJohn Kakisis
John Kakisis
Christos ManopoulosChristos Manopoulos
Christos Manopoulos
An intraluminal thrombus (ILT) is present in the majority of abdominal aortic aneurysms, playing a crucial role in their growth and rupture. Although most computational studies do not include the ILT, in the present study, this is taken into account, laying out the whole simulation procedure, namely, from computed tomography scans to medical image segmentation, geometry reconstruction, mesh generation, biomaterial modeling, finite element analysis, and post-processing, all carried out in open software. By processing the tomography scans of a patient’s aneurysm before and after rupture, digital twins are reconstructed assuming a uniform aortic wall thickness. The ILT and the aortic wall are assigned different biomaterial models; namely, the first is modeled as an isotropic linear elastic material, and the second is modeled as the Mooney–Rivlin hyperelastic material as well as the transversely isotropic hyperelastic Holzapfel–Gasser–Ogden nonlinear material. The implementation of the latter requires the designation of local Cartesian coordinate systems in the aortic wall, suitably oriented in space, for the proper orientation of the collagen fibers. The composite aneurysm geometries (ILT and aortic wall structures) are loaded with normal and hypertensive static intraluminal pressure. Based on the calculated stress and strain distributions, ILT seems to be protecting the aneurysm from a structural point of view, as the highest stresses appear in the thrombus-free areas of the aneurysmal wall.

1 May 2020 in Experimental Thermal and Fluid Science
Verified
Journal Article
Closed access
DGD. Gkiolas
D. Gkiolas
PKP. Kapiris
P. Kapiris
DMDimitrios Mathioulakis
Dimitrios Mathioulakis