The increased volume and complexity of flow cytometry (FCM) data resulting from the increased throughput greatly boosts the demand for reliable statistical methods for the analysis of multidimensional data. The Support Vector Machines (SVM) model can be used for classification recognition. However, the selection of penalty factor c and kernel parameter g in the model has a great influence on the correctness of clustering. To solve the problem of parameter optimization of the SVM model, a support vector machine algorithm of particle swarm optimization (PSO-SVM) based on adaptive mutation is proposed. Firstly, a large number of FCM data were used to carry out the experiment, and the kernel function adapted to the sample data was selected. Then the PSO algorithm of adaptive mutation was used to optimize the parameters of the SVM classifier. Finally, the cell clustering results were obtained. The method greatly improves the clustering correctness of traditional SVM. That also overcomes the shortcomings of PSO algorithm, which is easy to fall into local optimum in the iterative optimization process and has poor convergence effect in dealing with a large number of data. Compared with the traditional SVM algorithm, the experimental results show that, the correctness of the method is improved by 19.38%. Compared with the cross-validation algorithm and the PSO algorithm, the adaptive mutation PSO algorithm can also improve the correctness of FCM data clustering. The correctness of the algorithm can reach 99.79% and the time complexity is relatively lower. At the same time, the method does not need manual intervention, which promotes the research of cell group identification in biomedical detection technology.
Accurate measurement of corneal viscoelasticity is essential for diagnosing ocular diseases and understanding corneal biomechanics. Optical coherence elastography (OCE) is a promising technique for high-resolution imaging and quantitative assessment of tissue elasticity. However, existing OCE methods often struggle to provide comprehensive viscoelastic measurements of the cornea under varying intraocular pressures (IOPs). In this study, we present a method based on elastic wave dispersion for measuring corneal viscoelasticity using a handheld OCE system integrating non-contact air-puff excitation and a compact probe design. The elastic wave dispersion method, validated through experiments on agar phantoms, enables precise quantification of both elastic and viscous properties of the cornea. The system's effectiveness was further demonstrated by measuring corneal viscoelasticity in ex vivo porcine corneas at different IOPs. Our results show that the elastic wave dispersion method, combined with the handheld OCE system, provides a flexible and effective approach for assessing corneal viscoelasticity, offering valuable insights into corneal biomechanics under clinically relevant conditions.
Anisotropic elasticity measurements of the retina are essential for retinal disease diagnosis and function assessment. Optical coherence elastography (OCE) is a high-resolution imaging technique for mapping the elasticity distribution of tissues. However, previous OCE measurements quantified the tissue elasticity in a single direction, resulting in a biased estimation of the elastic properties. In this study, we propose an OCE method with acoustic radiation force (ARF) excitation to map the retinal anisotropic elasticity in the depth and lateral directions. The axial elasticity was analyzed using the natural frequency of free vibration, and the lateral elasticity was quantified using the elastic wave velocity. After evaluating the feasibility of the OCE method on the phantoms, the anisotropic elasticity of ex vivo porcine retinas was mapped. The results show that the OCE method with ARF excitation can assess the elasticity in orthogonal directions and provide a comprehensive understanding of the elasticity of the anisotropic tissues.
One of the essential factors influencing the prediction accuracy of multivariate calibration models is the quality of the calibration data. A local regression strategy, together with a wavelength selection approach, is proposed to build the multivariate calibration models based on partial least squares regression. The local algorithm is applied to create a calibration set of spectra similar to the spectrum of an unknown sample; the synthetic degree of grey relation coefficient is used to evaluate the similarity. A wavelength selection method based on simple-to-use interactive self-modeling mixture analysis minimizes the influence of noisy variables, and the most informative variables of the most similar samples are selected to build the multivariate calibration model based on partial least squares regression. To validate the performance of the proposed method, ultraviolet-visible absorbance spectra of mixed solutions of food coloring analytes in a concentration range of 20–200 µg/mL is measured. Experimental results show that the proposed method can not only enhance the prediction accuracy of the calibration model, but also greatly reduce its complexity.
Flow cytometry is being applied more extensively because of the outstanding advantages of multicolor fluorescence analysis. However, the intensity measurement is susceptible to the nonlinearity of the detection method. Moreover, in multicolor analysis, it is impossible to discriminate between fluorophores that spectrally overlap; this influences the accuracy of the fluorescence pulse signal representation. Here, we focus on spectral overlap in two-color analysis, and assume that the fluorescence follows the single exponential decay model. We overcome these problems by analyzing the influence of the spectral overlap quantitatively, which enables us to propose a method of fluorescence pulse signal representation based on time-delay estimation (between fluorescence and scattered pulse signals). First, the time delays are estimated using a modified chirp Z-transform (MCZT) algorithm and a fine interpolation of the correlation peak (FICP) algorithm. Second, the influence of hardware is removed via calibration, in order to acquire the original fluorescence lifetimes. Finally, modulated signals containing phase shifts associated with these lifetimes are created artificially, using a digital signal processing method, and reference signals are introduced in order to eliminate the influence of spectral overlap. Time-delay estimation simulation and fluorescence signal representation experiments are conducted on fluorescently labeled cells. With taking the potentially overlap of autofluorescence as part of the observed fluorescence spectrum, rather than distinguishing the individual influence, the results show that the calculated lifetimes with spectral overlap can be rectified from 8.28 and 4.86 ns to 8.51 and 4.63 ns, respectively, using the comprehensive approach presented in this work. These values agree well with the lifetimes (8.48 and 4.67 ns) acquired for cells stained with single-color fluorochrome. Further, these results indicate that the influence of spectral overlap can be eliminated effectively. Moreover, modulation, mixing with reference signals, and low-pass filtering are performed with a digital signal processing method, thereby obviating the need for a high-speed analog device and complex circuit system. Finally, the flexibility of the comprehensive method presented in this work is significantly higher than that of existing methods.