Zongqing Ma

Zongqing Ma

Auto-generated profile, based on publicly available information

Zongqing Ma

Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University 1 , Beijing 100192

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2025 in Applied Physics Letters
Verified
Journal Article
Closed access
JMJiawei Ma
Jiawei Ma
ZMZongqing Ma
Zongqing Ma
SLShuo Liu
Shuo Liu
CWChongyang Wang
Chongyang Wang
XMXiaochen Meng
Xiaochen Meng
JZJiang Zhu
Jiang Zhu
Accurate measurement of corneal viscoelasticity is essential for diagnosing ocular diseases and understanding corneal biomechanics. Optical coherence elastography (OCE) is a promising technique for high-resolution imaging and quantitative assessment of tissue elasticity. However, existing OCE methods often struggle to provide comprehensive viscoelastic measurements of the cornea under varying intraocular pressures (IOPs). In this study, we present a method based on elastic wave dispersion for measuring corneal viscoelasticity using a handheld OCE system integrating non-contact air-puff excitation and a compact probe design. The elastic wave dispersion method, validated through experiments on agar phantoms, enables precise quantification of both elastic and viscous properties of the cornea. The system's effectiveness was further demonstrated by measuring corneal viscoelasticity in ex vivo porcine corneas at different IOPs. Our results show that the elastic wave dispersion method, combined with the handheld OCE system, provides a flexible and effective approach for assessing corneal viscoelasticity, offering valuable insights into corneal biomechanics under clinically relevant conditions.

23 September 2024 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
JMJiawei Ma
Jiawei Ma
FFFan Fan
Fan Fan
CWChongyang Wang
Chongyang Wang
ZMZongqing Ma
Zongqing Ma
XMXiaochen Meng
Xiaochen Meng
JZJiang Zhu
Jiang Zhu
Anisotropic elasticity measurements of the retina are essential for retinal disease diagnosis and function assessment. Optical coherence elastography (OCE) is a high-resolution imaging technique for mapping the elasticity distribution of tissues. However, previous OCE measurements quantified the tissue elasticity in a single direction, resulting in a biased estimation of the elastic properties. In this study, we propose an OCE method with acoustic radiation force (ARF) excitation to map the retinal anisotropic elasticity in the depth and lateral directions. The axial elasticity was analyzed using the natural frequency of free vibration, and the lateral elasticity was quantified using the elastic wave velocity. After evaluating the feasibility of the OCE method on the phantoms, the anisotropic elasticity of ex vivo porcine retinas was mapped. The results show that the OCE method with ARF excitation can assess the elasticity in orthogonal directions and provide a comprehensive understanding of the elasticity of the anisotropic tissues.

12 May 2025 in Journal of Innovative Optical Health Sciences
Verified
Journal Article
Open access
HBHantao Bai
Hantao Bai
ZMZongqing Ma
Zongqing Ma
CGChuxiang Gao
Chuxiang Gao
JZJiang Zhu
Jiang Zhu
Scleral vessels on the surface of the human eye can provide valuable information about potential diseases or dysfunctions of specific organs, and vessel segmentation is a key step in characterizing the scleral vessels. However, accurate segmentation of blood vessels in the scleral images is a challenging task due to the intricate texture, tenuous structure, and erratic network of the scleral vessels. In this work, we propose a CNN-Transformer hybrid network named SVSNet for automatic scleral vessel segmentation. Following the typical U-shape encoder–decoder architecture, the SVSNet integrates a Sobel edge detection module to provide edge prior and further combines the Atrous Spatial Pyramid Pooling module to enhance its ability to extract vessels of various sizes. At the end of the encoding path, a vision Transformer module is incorporated to capture the global context and improve the continuity of the vessel network. To validate the effectiveness of the proposed SVSNet, comparative experiments are conducted on two public scleral image datasets, and the results show that the SVSNet outperforms other state-of-the-art models. Further experiments on three public retinal image datasets demonstrate that the SVSNet can be easily applied to other vessel datasets with good generalization capability.

18 April 2026 in Journal of Innovative Optical Health Sciences
Verified
Journal Article
Open access
PDF file
CGChuxiang Gao
Chuxiang Gao
ZMZongqing Ma
Zongqing Ma
HBHantao Bai
Hantao Bai
YSYixuan Shi
Yixuan Shi
FFFan Fan
Fan Fan
JZJiang Zhu
Jiang Zhu
Coronary heart disease (CHD) is a prevalent and life-threatening chronic cardiovascular condition, and early screening and diagnosis are essential for improving patient outcomes. Traditional diagnostic methods, such as electrocardiography, echocardiography, and coronary angiography, typically require specialized equipment, expert interpretation, and, in some cases, invasive procedures, thereby limiting their accessibility and scalability for population-wide screening. In this paper, we propose a novel, painless, noninvasive, and rapid auxiliary diagnostic approach for CHD based on scleral images. Specifically, we present the ScleraMIL model, a multi-instance learning framework that integrates the strengths of Convolutional Neural Networks (CNNs) and Vision Transformer (ViT) architectures to capture both local and global representations across multiple scleral images from each individual. To ensure the model focuses on scleral features, the Mamba-UNet segmentation model is first employed to precisely extract the scleral region from the raw ocular image. Then, each subject’s ten segmented scleral images (five per eye) are treated as instances forming a bag with a single patient-level label. These instances are processed through a CNN-based feature extractor, followed by a Transformer encoder that models inter-image dependencies for discriminative feature fusion, and finally passed to a classification head to predict the probability of CHD. Experimental results demonstrate that ScleraMIL achieves superior performance on key metrics such as accuracy, AUC, F1-score, and recall, significantly outperforming other deep learning and multiple instance learning methods. This work explores the feasibility of using scleral imaging as a potential biomarker for CHD classification and represents a promising step toward intelligent, accessible, and noninvasive cardiovascular risk assessment.

13 April 2026 in Applied Physics Letters
Verified
Journal Article
Closed access
HFHuiyi Fang
Huiyi Fang
XMXiaochen Meng
Xiaochen Meng
CWChongyang Wang
Chongyang Wang
FFFan Fan
Fan Fan
ZMZongqing Ma
Zongqing Ma
JZJiang Zhu
Jiang Zhu
Strain-based optical coherence elastography (OCE) is a functional imaging modality derived from optical coherence tomography (OCT), which evaluates biomechanical properties by measuring tissue strain. However, conventional Doppler phase-based strain estimation is highly susceptible to phase wrapping, particularly under conditions of unstable scanning speed, which is often exacerbated by non-uniform rotational distortion (NURD) in proximally driven endoscopic probes. To overcome these limitations, we propose a distal rotary scanning endoscopic OCE system integrated with a balloon catheter. By combining balloon inflation-induced excitation with circumferential scanning, the system enables stable and uniform elastography imaging of intestinal tissue while mitigating NURD-related artifacts. Displacement fields are estimated by calculating inter-frame phase differences of OCT images, based on which radial strain maps are reconstructed, thereby simplifying the phase-unwrapping process. Experiments conducted on tissue-mimicking phantoms and ex vivo porcine intestines confirm the feasibility of the proposed method. The results indicate that the system can simultaneously capture high-resolution structural images and radial strain information from localized intestinal tissues, demonstrating significant potential for clinical applications in the early diagnosis and therapeutic monitoring of intestinal diseases.