Rabie Outayad

Dr. Rabie Outayad

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2025 in Nuclear Analysis
Verified
Journal Article
Open access
BABrahim EL Azzaoui
Brahim EL Azzaoui
Ouadie KabachOuadie Kabach
Ouadie Kabach
YAYounes EL Abbari
Younes EL Abbari
MMMohamed Youssef Mohamed MESSOUS
Mohamed Youssef Mohamed MESSOUS
KNKhalid Nabaoui
Khalid Nabaoui
EAEl Mehdi Alibrahmi
El Mehdi Alibrahmi

26 November 2016 in International Journal of Environmental Science and Technology
Verified
Journal Article
Closed access
PDF file
ZFZineb Faiz
Zineb Faiz
SFS. Fakhi
S. Fakhi
ABA. Bouih
A. Bouih
RORabie Outayad
Rabie Outayad
ABA. Benkdad
A. Benkdad
HHH. Hannache
H. Hannache

10 September 2024 in Atom Indonesia
Verified
Journal Article
Open access
PDF file
BABrahim El AZZAOUI
Brahim El AZZAOUI
Ouadie KabachOuadie Kabach
Ouadie Kabach
RORabie Outayad
Rabie Outayad
MMMohamed Youssef Mohamed MESSOUS
Mohamed Youssef Mohamed MESSOUS
KBK. Bergaoui
K. Bergaoui
AKA. Kharchaf
A. Kharchaf
Disused Sealed Radioactive Sources (DSRS) present significant risks of radiation exposure and environmental contamination during dismantling. Despite their sealed nature, DSRS can emit ionizing radiation, necessitating careful management to mitigate health risks. This article presents the MCNP simulation results of dosimetric operational quantities, namely Hp(3), Hp(10), and H(0.07), for hands and feet. This study focuses on a 60Co source, due to its high radiation energy levels and widespread use in various socioeconomic sectors. The assessment of radiation exposure levels enabled the improvement of occupational radiation protection measures related to critical areas and steps in the dismantling process. According to the obtained results with the 60Co source at its initial activity, and considering the maximum task duration, the dismantling process contributes to approximately 72.35 % of the daily dose limit of 80 µSv for worker category A, for the whole body. Therefore, these findings can contribute to a better understanding of radiation exposure risks and confirm compliance with regulatory requirements.

29 August 2014
Verified
Book Chapter
Closed access
PDF file
SFSaid Fakhi
Said Fakhi
RORabie Outayad
Rabie Outayad
EFElmehdi Fait
Elmehdi Fait
ZFZineb Faiz
Zineb Faiz
CGC. Galindo
C. Galindo
ANAbdelmjid Noureddine
Abdelmjid Noureddine

1 April 2026 in Nuclear Analysis
Verified
Journal Article
Open access
BABrahim EL Azzaoui
Brahim EL Azzaoui
Ouadie KabachOuadie Kabach
Ouadie Kabach
RORabie Outayad
Rabie Outayad
ALAbdeslam Lachhab
Abdeslam Lachhab
AOanas otmani
anas otmani
ECEl Mahjoub Chakir
El Mahjoub Chakir

1 January 2011
Verified
Book Chapter
Closed access
PDF file
SFSaid Fakhi
Said Fakhi
RORabie Outayad
Rabie Outayad
EFElmehdi Fait
Elmehdi Fait
MMMustapha Mouflih
Mustapha Mouflih
MRMarusia Rentería
Marusia Rentería
ANAbdelmjid NOURREDDINE
Abdelmjid NOURREDDINE