Asphalt-based composites have the ability to heal themselves.without the aid of external influences (energy supply or material supplement), the self-healing ability of asphalt mixture is quite limited. In this paper, the efficiency of self-healing of asphalt mixture with Ni-Zn ferrite powders was analyzed based on the concept of microwave heating. We focused on assessing the characteristics of polyurethane (PU), base or styrene-butadiene-styrene (SBS) modified asphalt and its mixtures. The recovery rate of stiffness modulus and the fatigue life extension ratio were adopted to evaluate the self-healing efficiency of asphalt mixture. The analysis results proved that Ni-Zn ferrite powders can promote the self-healing ability of asphalt mixture significantly, the fatigue life extension ratio of 50% damaged ferrite-filled asphalt mixture can reach 1.33.
In order to clarify the road performance and load response behavior of polyurethane mixtures, a low-temperature bending test, dynamic modulus test, rutting test, Hamburg rutting test, and four-point bending fatigue test were conducted on multi-crushed stone polyurethane concrete (SPC-16) and polyurethane concrete (PC-20) as the test objects, and the results were compared with the road performance of an asphalt mastic crushed stone mixture (SMA-13). The differences in the load response between two typical polyurethane mixture pavement structures and a typical asphalt pavement structure were analyzed under four working conditions: a normal-temperature standard load, normal-temperature heavy load, high-temperature standard load, and high-temperature heavy load. The results showed that the low-temperature flexural tensile strength of the polyurethane mixture was 1.3–1.7-times that of SMA-13, the maximum flexural tensile strain was 1.1–1.8-times that of SMA-13, the dynamic stability of the polyurethane mixture was more than 15-times that of SMA-13, and the fatigue life of the polyurethane mixture was 8–12-times that of SMA-13. The surface deflection, base stress, and surface strain of the typical asphalt pavement structures and two typical polyurethane mixture pavement structures at the same temperature all increased with an increase in the load. The load response of the polyurethane mixture pavement structures under high-temperature conditions was relatively stable.
29 August 2021 in Waves in Random and Complex Media
In this research, the nonlinear vibration behavior of axially functionally graded (AFG) nano-scale truncated conical tubes (with non-uniform cross-section), including the porosity, is presented for the first time based on the Euler-Bernoulli beam theory and the von-Kármán’s nonlinear strain-displacement and nonlinear nonlocal boundary conditions. The effect of being at the tapered nanosize model is supposedly based on the nonlocal strain gradient theory using the Hamilton principle to extract the equation of motions and nonlinear time-dependent nonlocal boundary conditions. The material properties and thickness of nano-tube are varying along the length of tubes. The generalized differential quadrature method (GDQM) is utilized with the iteration method to solve the complicated nonlinear equations. The numerical results in tabular and graphical styles present for various nonlinear amplitudes, the AFG power indexes, the rate of the cross-section change, the porosity parameter, and the nonlocal gradient strain parameter for both simply supported, fully clamped, and simply supported-clamped boundary conditions in detail.
A salt fog environment is a severe problem for stay cables of long-span cable-stayed bridges. This paper studies the salt fog corrosion influences for parallel-wire stay cables. First, accelerated corrosion tests were conducted using acetic acid salt spray for exposure periods from 1 d to 60 d; subsequently, a multiparameter reference model for corrosion stress was employed to describe the influence of corrosion of steel wires. Fatigue damage evolution models of multistep loading were then used to establish recursion formulas for the probabilistic character of the fatigue life of parallel-wire stay cables. The results indicate that the fraction of wires with short fatigue lives dominates the fatigue life of the stay cable. The corrosion effects on fatigue life for both steel wires and stay cables are nearly the same. Although the variance of fatigue life of the stay cable is much smaller than that of the steel wire, the fatigue performance of the stay cable becomes stable. Compared with no-stress and alternating stress, the change is less obvious under static stress. Therefore, to prevent premature fatigue failures of parallel-wire stay cables, avoiding corrosion in the steel wires during the in-service period is crucial.
The corrosion and microstructure behavior features, such as steel strand corrosion and corrosive wear of the as-prepared composite coatings and substrates were investigated. It is found that the experimental pitting depth followed a normal distribution and both the location and scale parameters increased with the corrosion degree. The fatigue test results indicated that corrosion could cause a significant decrease in the fatigue life of corroded steel wires. The substrate exhibited corrosion-accelerating wear, while the coatings exhibited wear accelerating corrosion. A method based on 3D measurements and AFGROW software was proposed to predict the remaining fatigue life of corroded steel wires. The predicted fatigue lives agreed well with the test results.
31 July 2015 in The Open Civil Engineering Journal