Ken Bryan Fernandez

Dr. Ken Bryan Fernandez

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2024 in Building and Environment
Verified
Journal Article
Closed access
RIRyu Itokazu
Ryu Itokazu
KFKen Bryan Fernandez
Ken Bryan Fernandez
KKKazuki Kuga
Kazuki Kuga
Naoki IKEGAYANaoki IKEGAYA
Naoki IKEGAYA
KIKazuhide Ito
Kazuhide Ito


29 March 2026 in Fluids
Verified
Journal Article
Open access
PDF file
RERen Paulo Cruz Estaquio
Ren Paulo Cruz Estaquio
MCMa Kevina Canlas
Ma Kevina Canlas
NANeil Astrologo
Neil Astrologo
JEJob Immanuel Encarnacion
Job Immanuel Encarnacion
JAJoshua Cunanan Agar
Joshua Cunanan Agar
JRJoseph Gerard Reyes
Joseph Gerard Reyes
Indoor exposure to particulate matter (PM) depends on ventilation-driven transport, yet sensor placement in real rooms is often based on limited point data. This study develops and experimentally validates a transient CFD framework, using RANS airflow coupled with Lagrangian discrete phase tracking, to map PM2.5 and PM10 in a full-scale 2.0 × 3.0 × 2.5 m bedroom with a fixed, non-oscillating pedestal fan and an open window. Airflow was verified by grid independence and validated against 10-point velocity measurements (RMSE = 0.108 m·s−1). Incense experiments (≈31 min burn) provided PM time series over the first 60 min at 16 locations on two heights; emission rate, burning time, and air-change rate (1.96–5.39 ACH) were calibrated so that accepted models achieved aggregate R2 > 0.90. Spatial mapping on a 0.5 m grid shows that PM behavior is governed primarily by airflow-defined accumulation pockets rather than by source proximity alone. A near-source region consistently captured strong early-time peaks, whereas remote low-exchange pockets remained elevated during the decay phase. For PM2.5, the most persistent hotspot is a ceiling-adjacent recirculation pocket, while for PM10, gravitational settling shifted the dominant hotspots toward floor-layer, low-velocity regions. An exposure score combining normalized peak and time-averaged concentrations, interpreted together with particle-track persistence metrics, distinguished transiently traversed regions from true retention pockets. The results show that sensor placement should follow the monitoring objective: near-source regions are more responsive to peak events, ceiling pockets are more suitable for persistent PM2.5 monitoring, and floor hotspots are more critical for PM10. No single fixed sensor location adequately represents both particle sizes in the present bedroom and ventilation configuration.

16 June 2023 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
RIRyu Itokazu
Ryu Itokazu
KFKen Bryan Fernandez
Ken Bryan Fernandez
KIKazuhide Ito
Kazuhide Ito
Natural and cross ventilation is recognized as an important measure for introducing outdoor fresh air to indoor without the use of mechanical equipment. Plenty of fruitful studies for elucidating natural and cross ventilation mechanisms have been reported adopting experimental and computational methods. Field and wind tunnel experiments could provide substantial flow information on indoor-outdoor interaction in actual or reduced model conditions. However, these approaches were relatively costly and time-consuming and limited in terms of spatial and temporal resolutions. Computational fluid dynamics approaches are promising complementary technique to these methods. In this study, we performed isothermal CFD simulations for both airflow and concentration fields for cross-ventilation conditions sheltered by surrounding buildings with two different opening conditions. ANSYS/Fluent was utilized to perform CFD using RANS simulation. Heterogeneity of ventilation efficiencies determined by concentration distributions in cross-ventilated room model were quantitatively analyzed using ventilation efficiencies, e.g., age of air. The results showed that the location of the openings had a significant impact on the cross-ventilation rate, creating completely different concentration fields, and ventilation efficiencies indices could quantitatively demonstrate the formation mechanisms of scalar concentration distributions in an indoor space.

5 August 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
JCJustin Josef Callejo
Justin Josef Callejo
TFTimothy Micah Formoso
Timothy Micah Formoso
KFKen Bryan Fernandez
Ken Bryan Fernandez
High heat indices have frequently prompted widespread class cancellations across the Philippines. Compounded by the ongoing national energy crisis, it has become imperative to evaluate thermal comfort models tailored to the Philippine context while simultaneously promoting energy efficiency in air-conditioned classrooms. This study investigated the thermal comfort of occupants within an air-conditioned lecture room in the Philippines. Specifically, the air-conditioning setpoint was varied from 21.00°C to 27.00°C while concurrent sensor measurements were conducted to calculate the Predicted Mean Vote (PMV) and subjective surveys were administered to determine the occupants' Thermal Sensation Votes (TSV).The results showed that the PMV model slightly underestimated warmth compared to the TSV, although both produced similar neutral temperatures (26.3°C and 26.0°C) and substantially overlapping acceptable temperature ranges (PMV/TSV = -0.5 to +0.5). Further analysis revealed that clothing insulation and prior physical activity significantly influenced thermal perception. Notably, a decrease in clothing insulation could increase neutral temperature by up to 1.00°C, while occupants who were sitting prior to the session exhibited an approximate 2.00°C increase in neutral temperature compared to those who had walked to the room. Finally, a validation phase demonstrated that adjusting the air-conditioning setpoints to achieve these neutral temperatures significantly improved occupant thermal comfort while reducing cooling energy consumption by approximately 40% to 61%. These findings provide localized thermal comfort data for tropical educational environments and offer actionable recommendations to enhance occupant comfort while maximizing institutional energy efficiency.

16 June 2023 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
KFKen Bryan Fernandez
Ken Bryan Fernandez
Naoki IKEGAYANaoki IKEGAYA
Naoki IKEGAYA
KIKazuhide Ito
Kazuhide Ito
We conducted isothermal large-eddy simulations to generate the velocity and concentration distributions to investigate the air pollution transport from outside to inside of a space surrounded by urban-like block arrays. Contrary to previous study, we assumed that the pollution in the form of scalars are generated outdoors and not indoors which we placed at: 1) middle of window, 2) near window wall, 3) middle of street canyon at ground level, and 4) middle of street canyon at window level. Results showed that regardless of scalar source location, the scalars accumulated inside the indoor space which can be explained by the downdraft effect that are typically found in urban environments. The downdraft effect produced vortices outside and inside the indoor space. For scalars near window, indoor vortex drove the concentration to indoors. On the other hand, outdoor vortex transported the scalars located at street canyon to reach the window where they were eventually transported to indoors also due to indoor vortex. The average normalized indoor concentrations found in this study are 1.25 – 1.50, 1.00 – 1.75, 0.25 – 0.50, and 0.0 – 0.25 for scalars C 1, C 2, C 3, and C 4, respectively. Our study suggests that for natural ventilation studies of urban environments where air pollution is significant, outdoor effects should also be carefully considered.