Jiří Dluhoš

Mr. Jiří Dluhoš

TESCAN - Product Manager FIB-SEM
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Nano Energy
Verified
Journal Article
Closed access
Tan SuiTan Sui
Tan Sui
BSBohang Song
Bohang Song
JDJiří Dluhoš
Jiří Dluhoš
LLLi Lu
Li Lu
Alexander KorsunskyAlexander Korsunsky
Alexander Korsunsky

18 February 2022 in Science Advances
Verified
Journal Article
Open access
BZBin Zhu
Bin Zhu
YWYiqiang Wang
Yiqiang Wang
JDJiří Dluhoš
Jiří Dluhoš
ALAndy J. London
Andy J. London
MGMichael Gorley
Michael Gorley
Tan SuiTan Sui
Tan Sui
The plasma-facing components of future fusion reactors, where the Eurofer97 is the primary structural material, will be assembled by laser-welding techniques. The heterogeneous residual stress induced by welding can interact with the microstructure, resulting in a degradation of mechanical properties and a reduction in joint lifetime. Here, a Xe + plasma focused ion beam with digital image correlation (PFIB-DIC) and nanoindentation is used to reveal the mechanistic connection between residual stress, microstructure, and microhardness. This study is the first to use the PFIB-DIC to evaluate the time-resolved multiscale residual stress at a length scale of tens of micrometers for laser-welded Eurofer97. A nonequilibrium microscale residual stress is observed, which contributes to the macroscale residual stress. The microhardness is similar for the fusion zone and heat-affected zone (HAZ), although the HAZ exhibits around ~30% tensile residual stress softening. The results provide insight into maintaining structural integrity for this critical engineering challenge.

21 August 2018 in Materials
Verified
Journal Article
Open access
PDF file
Tan SuiTan Sui
Tan Sui
JDJiří Dluhoš
Jiří Dluhoš
TLTao Li
Tao Li
Kaiyang ZengKaiyang Zeng
Kaiyang Zeng
ACAdrian Cernescu
Adrian Cernescu
Alexander KorsunskyAlexander Korsunsky
Alexander Korsunsky
Peritubular dentine (PTD) and intertubular dentine (ITD) were investigated by 3D correlative Focused Ion Beam (FIB)-Scanning Electron Microscopy (SEM)-Energy Dispersive Spectroscopy (EDS) tomography, tapping mode Atomic Force Microscopy (AFM) and scattering-type Scanning Near-Field Optical Microscopy (s-SNOM) mapping. The brighter appearance of PTD in 3D SEM-Backscattered-Electron (BSE) imaging mode and the corresponding higher grey value indicate a greater mineral concentration in PTD (~160) compared to ITD (~152). However, the 3D FIB-SEM-EDS reconstruction and high resolution, quantitative 2D map of the Ca/P ratio (~1.8) fail to distinguish between PTD and ITD. This has been further confirmed using nanoscale 2D AFM map, which clearly visualised biopolymers and hydroxyapatite (HAp) crystallites with larger mean crystallite size in ITD (32 ± 8 nm) than that in PTD (22 ± 3 nm). Correlative microscopy reveals that the principal difference between PTD and ITD arises primarily from the nanoscale packing density of the crystallites bonded together by thin biopolymer, with moderate contribution from the chemical composition difference. The structural difference results in the mechanical properties variation that is described by the parabolic stiffness-volume fraction correlation function introduced here. The obtained results benefit a microstructure-based mechano-chemical model to simulate the chemical etching process that can occur in human dental caries and some of its treatments.

3 June 2021 in Energy & Environmental Materials
Verified
Journal Article
Open access
PDF file
XYXuhui Yao
Xuhui Yao
TSTomas Samoril
Tomas Samoril
JDJiří Dluhoš
Jiří Dluhoš
JWJohn F. Watts
John F. Watts
ZDZhijia Du
Zhijia Du
YZYunlong Zhao
Yunlong Zhao
Despite the long‐established rocking‐chair theory of lithium‐ion batteries (LIBs), developing novel characterization methodology with higher spatiotemporal resolution facilitates a better understanding of the solid electrolyte interphase studies to shape the reaction mechanisms. In this work, we develop a Xenon ion plasma focused ion beam (Xe+ PFIB)‐based characterization technique to probe the cross‐sectional interface of both ternary cathode and graphite anode electrodes, with the focus on revealing the chemical composition and distribution underneath the electrode surface by in‐depth analysis of secondary ions. Particularly, the lithium fluoride is detected in the pristine cathode prior to contact with the electrolyte, reflecting that the electrode degradation is in the form of the loss of lithium inventory during electrode preparation. This degradation is related to the hydrolysis of the cathode material and the decomposition of the PVDF binder. Through the quantitative analysis of the transition‐metal degradation products, manganese is found to be the dominant element in the newly formed inactive fluoride deposition on the cathode, while no transition metal signal can be found inside the anode electrode. These insights at high resolution implemented via a PFIB‐based characterization technique not only enrich the understanding of the degradation mechanism in the LIBs but also identify and enable a high‐sensitivity methodology to obtain the chemical survey at the subsurface, which will help remove the capacity‐fade observed in most LIBs.

3 November 2019 in Materials
Verified
Journal Article
Open access
PDF file
POPetra Ohnistova
Petra Ohnistova
MPMiroslav Piska
Miroslav Piska
MPMartin Petrenec
Martin Petrenec
JDJiří Dluhoš
Jiří Dluhoš
JHJana Hornikova
Jana Hornikova
PŠPavel Šandera
Pavel Šandera
The fatigue properties of thermo-mechanically treated and machined aluminum alloy 7475-T7351 have been studied. The applied advanced machining strategy induced intensive plastic deformation on the machined surface under defined cutting conditions. Therefore, a detailed study of 3D surface topography was performed. Advanced characterization of the material structure and electron back scattered diffraction mapping of selected chemical phases were performed, as well as energy dispersive X-ray analysis of the surface. Advanced mechanical properties of the material were investigated in situ with a scanning electron microscope that was equipped with a unique tensile fixture. The fatigue results confirmed an evident dispersion of the data, but the mechanism of crack nucleation was established. Fracture surface analysis showed that the cracks nucleated at the brittle secondary particles dispersed in the material matrix. The surface topography of samples that had been machined in wide range of cutting/deformation conditions by milling has not proved to be a decisive factor in terms of the fatigue behavior. The incoherent interface and decohesion between the alumina matrix and the brittle secondary phases proved to significantly affect the ultimate strength of the material. Tool engagement also affected the fatigue resistance of the material.

8 July 2020 in Materials
Verified
Journal Article
Open access
PDF file
LZLukáš Zábranský
Lukáš Zábranský
KBKatarína Bernátová
Katarína Bernátová
JDJiří Dluhoš
Jiří Dluhoš
RVRostislav Váňa
Rostislav Váňa
PSPavel Souček
Pavel Souček
VBVilma Bursikova
Vilma Bursikova
This research was devoted to studying the influence of the taper angle on the micro-compression of micro-pillars fabricated from near-amorphous and nanocrystalline Mo-B-C coatings. A series of micro-pillars with a taper angle between 4–14° was fabricated by focused ion beam technique. The deformation mechanism was found to be dependent on the taper and, also, on the crystallinity of the coating. In order to obtain correct values of yield strength and Young’s modulus, three empirical models of stress correction were experimentally tested, and the results were compared with nanoindentation measurements. It was shown that the average stress correction model provided comparable results with nanoindentation for the yield strength for taper angles up to ~10°. On the other hand, the average radius or area model gave the most precise results for Young’s modulus if the taper angle was <10°.