Hachul Jung

Mr. Hachul Jung

Osong Medical Innovation Foundation
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2021 in Nature Electronics
Verified
Journal Article
Closed access
PDF file
SCSungwoo Chun
Sungwoo Chun
JKJong-Seok Kim
Jong-Seok Kim
YYYongsang Yoo
Yongsang Yoo
YCYoung In Choi
Young In Choi
SJSung Jun Jung
Sung Jun Jung
Seungjun ParkSeungjun Park
Seungjun Park

7 March 2012 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HJHachul Jung
Hachul Jung
JMJin-Hee Moon
Jin-Hee Moon
DBDong-Hyun Baek
Dong-Hyun Baek
JLJae-Hee Lee
Jae-Hee Lee
YCYoon-Young Choi
Yoon-Young Choi
SLSang-Hoon Lee
Sang-Hoon Lee
We fabricated a carbon nanotube (CNT)/ polydimethylsiloxane (PDMS) composite-based dry ECG electrode that can be readily connected to conventional ECG devices, and showed its long-term wearable monitoring capability and robustness to motion and sweat. While the dispersion of CNTs in PDMS is challenging, we optimized the process to disperse untreated CNTs within PDMS by mechanical force only. The electrical and mechanical characteristics of the CNT/PDMS electrode were tested according to the concentration of CNTs and its thickness. The performances of ECG electrodes were evaluated by using 36 types of electrodes which were fabricated with different concentrations of CNTs, and with a differing diameter and thickness. The ECG signals were obtained by using electrodes of diverse sizes to observe the effects of motion and sweat, and the proposed electrode was shown to be robust to both factors. The CNT concentration and diameter of the electrodes were critical parameters in obtaining high-quality ECG signals. The electrode was shown to be biocompatible from the cytotoxicity test. A seven-day continuous wearability test showed that the quality of the ECG signal did not degrade over time, and skin reactions such as itching or erythema were not observed. This electrode could be used for the long-term measurement of other electrical biosignals for ubiquitous health monitoring including EMG, EEG, and ERG.

1 January 2012 in Nature Communications
Verified
Journal Article
Closed access
PDF file
GJGi Seok Jeong
Gi Seok Jeong
DBDong-Hyun Baek
Dong-Hyun Baek
HJHachul Jung
Hachul Jung
JSJi Hoon Song
Ji Hoon Song
JMJin Hee Moon
Jin Hee Moon
SLSang-Hoon Lee
Sang-Hoon Lee

29 April 2019 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
SCSungwoo Chun
Sungwoo Chun
WSWonkyeong Son
Wonkyeong Son
DKDa Wan Kim
Da Wan Kim
JLJihyun Lee
Jihyun Lee
HMHyeongho Min
Hyeongho Min
CCChangsoon Choi
Changsoon Choi

25 January 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
WSWonkyeong Son
Wonkyeong Son
SCSungwoo Chun
Sungwoo Chun
JLJae Myeong Lee
Jae Myeong Lee
YLYourack Lee
Yourack Lee
JPJeongmin Park
Jeongmin Park
CCChangsoon Choi
Changsoon Choi
Highly deformable and electrically conductive fibres with multiple functionalities may be useful for diverse applications. Here we report on a supercoil structure (i.e. coiling of a coil) of fibres fabricated by inserting a giant twist into spandex-core fibres wrapped in a carbon nanotube sheath. The resulting supercoiled fibres show a highly ordered and compact structure along the fibre direction, which can sustain up to 1,500% elastic deformation. The supercoiled fibre exhibits an increase in resistance of 4.2% for stretching of 1,000% when overcoated by a passivation layer. Moreover, by incorporating pseudocapacitive-active materials, we demonstrate the existence of superelastic supercapacitors with high linear and areal capacitance values of 21.7 mF cm-1and 92.1 mF cm-2, respectively, that can be reversibly stretched by 1,000% without significant capacitance loss. The supercoiled fibre can also function as an electrothermal artificial muscle, contracting 4.2% (percentage of loaded fibre length) when 0.45 V mm-1is applied.

20 March 2012 in BioChip Journal
Verified
Journal Article
Closed access
PDF file
JLJae Hee Lee
Jae Hee Lee
YNYoung Woo Nam
Young Woo Nam
HJHachul Jung
Hachul Jung
DBDong-Hyun Baek
Dong-Hyun Baek
SLSang-Hoon Lee
Sang-Hoon Lee
JHJoung Sook Hong
Joung Sook Hong