The increasing penetration of renewable energy exposes doubly fed induction generator (DFIG)-based wind power systems to weak-grid conditions, making them susceptible to low-frequency and subsynchronous oscillations. Although grid-forming (GFM) control enhances weak-grid adaptability, the resulting high-order small-signal model complicates stability analysis and controller design. This paper establishes a 15th-order state-space model for a GFM-DFIG system. Eigenvalue analysis is performed to identify the dominant oscillation modes and to reveal their sensitivity to controller parameters and grid strength. To reduce computational burden, a model order reduction method combining singular perturbation theory and participation factor analysis is proposed, yielding an eighth-order model that preserves dominant oscillatory characteristics. An additional damping control strategy is then designed using the reduced model. Simulations validate the reduced model’s accuracy and demonstrate the damping control’s effectiveness in mitigating oscillations. This paper provides an effective framework for stability analysis, reduced-order modeling, and damping control design for GFM-DFIG systems.
Carbon capture is pivotal for achieving carbon neutrality; however, its high energy consumption severely limits the operational flexibility of power plants and remains a key challenge. This study, targeting a full flue gas carbon capture scenario for a 1000 MW coal-fired power plant, identified the dual-element (“steam” and “power generation”) coupling convergence mechanism. Based on this mechanism, a comprehensive set of mathematical model equations for the “carbon–electricity–heat” coupling process is established. This model quantifies the dynamic relationship between key operational parameters (such as unit load, capture rate, and thermal consumption level) and system performance metrics (such as power output and specific power penalty). To address the challenge of flexible operation, this paper further proposes two innovative coupled modes: steam thermal storage and chemical solvent storage. Model-based quantitative analysis indicated the following: (1) The power generation impact rate under full THA conditions (25.7%) is lower than that under 30% THA conditions (27.7%), with the specific power penalty for carbon capture decreasing from 420.7 kW·h/tCO2 to 366.7 kW·h/tCO2. (2) Thermal consumption levels of the capture system are a critical influencing factor; each 0.1 GJ/tCO2 increase in thermal consumption leads to an approximate 2.83% rise in unit electricity consumption. (3) Steam thermal storage mode effectively reduces peak-period capture energy consumption, while the chemical solvent storage mode almost fully eliminates the impact on peak power generation and provides optimal deep peak-shaving capability and operational safety. Furthermore, these modeling results provide a basis for decision-making in plant operations.