Katarzyna Kresse-Walczak

Dr. Katarzyna Kresse-Walczak


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2026 in Materials
Verified
Journal Article
Open access
PDF file
JSJoanna Smardz
Joanna Smardz
KKKatarzyna Kresse-Walczak
Katarzyna Kresse-Walczak
HMHeike Meissner
Heike Meissner
KBKlaus Boening
Klaus Boening
JWJoanna Wezgowiec
Joanna Wezgowiec
Mieszko WieckiewiczMieszko Wieckiewicz
Mieszko Wieckiewicz
Occlusal splints are a type of intraoral appliance that are widely used for the management of temporomandibular disorders and bruxism, yet limited evidence exists regarding the comparative effects of combined aging on conventional and digitally manufactured materials. This in vitro study evaluated the influence of thermal and mechanical aging on the flexural properties of three materials commonly used for the manufacturing of occlusal devices: self-curing poly(methyl methacrylate) (PMMA, control), light-cured urethane dimethacrylate (UDMA)-based resin, and stereolithography (SLA)-printed photopolymer. Seventy-two standardized specimens (n = 24 per material; 64 × 10 × 3.3 mm) were fabricated, then randomly allocated to three groups (n = 8): control, thermocycling (10,000 cycles, 5 °C/55 °C), and combined thermocycling with mechanical loading (1000 cycles). Flexural strength and modulus were determined by three-point bending tests and analyzed using a two-way analysis of variance (ANOVA) with Tukey’s post hoc test (α = 0.05). Thermocycling significantly reduced flexural strength in PMMA (65.19 ± 6.68 to 57.94 ± 7.15 MPa) and SLA (67.67 ± 1.54 to 59.37 ± 8.80 MPa) groups (p < 0.05), while UDMA group (45.489 ± 3.905 to 43.123 ± 4.367 MPa) demonstrated no significant changes (p ≥ 0.05). UDMA exhibited substantially and significantly lower flexural properties compared to PMMA and SLA across all conditions (p < 0.0001). Thermal aging slightly compromises the mechanical properties of PMMA and SLA-printed materials, whereas UDMA-based resins exhibit good aging resistance but considerably lower initial values. While UDMA-based resin showed superior aging resistance, its lower baseline mechanical properties may limit its application in high-stress clinical scenarios compared to PMMA and SLA-printed materials. Material selection should consider both initial properties and long-term environmental changes.