Khairul Anwar Anwar Ayob

Dr. Khairul Anwar Anwar Ayob

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2021 in Joint Diseases and Related Surgery
Verified
Journal Article
Open access
PDF file
KAKhairul Anwar Anwar Ayob
Khairul Anwar Anwar Ayob
AMAzhar M. Merican
Azhar M. Merican
SSShahrul-Hisham Sulaiman
Shahrul-Hisham Sulaiman
ARAhmad Rafizi Hariz Ramli
Ahmad Rafizi Hariz Ramli
Injuries to the pelvic vasculature during total hip arthroplasties are rare but have serious consequence. They demand urgent and early identification so that appropriate treatment can be instituted. If the bleeding is severe, cardiovascular compromise occurs intraoperatively and this will alert the surgeon of this possibility during acetabular screw placement. Alternatively, a delay in diagnosis can occur because the bleeding and the injured vessel are in the pelvic cavity and not visualized during the surgery. In this article, we report two cases from our center occurring within a six-month interval that sustained a vascular injury during acetabular drilling for screw placement for cementless cup fixation. Each case had a different vessel injury and different lessons can be learned from these rare injuries. The first case had an injury of the inferior gluteal artery following a breach of the sciatic notch. The vessel was treated with percutaneous embolization. The second case demonstrated a venous injury, following a medial protrusio technique for congenital hip dysplasia and a short anterosuperior screw, transecting the external iliac vein. This was subsequently repaired using an endovascular technique. We conclude the reasons for these vessel injuries after analyzing advanced imaging, discuss measures to avoid vessel injury and detail the minimally invasive method for their treatment.

2 February 2026 in Medicina
Verified
Journal Article
Open access
PDF file
HYHong Yeol Yang
Hong Yeol Yang
JSJong Keun Seon
Jong Keun Seon
KAKhairul Anwar Anwar Ayob
Khairul Anwar Anwar Ayob
Background and Objectives: Mechanical alignment (MA) has long been the gold standard in total knee arthroplasty (TKA), aiming for neutral hip–knee–ankle alignment with proven long-term survivorship. However, up to 20% of patients remain dissatisfied, often due to neglect of individual constitutional limb variation and subsequent soft tissue imbalance. This has driven the development of alternative alignment philosophies. This current concepts review aims to determine the various evolving alignment strategies, elucidate their underlying principles, and demonstrate the available clinical outcomes data. Materials and Methods: This review examines MA and the paradigm shift towards personalized alignment techniques, including Kinematic Alignment (KA), restricted Kinematic Alignment (rKA), inverse Kinematic Alignment (iKA), adjusted mechanical alignment (aMA), and the most recent evolution, Functional Alignment (FA). Results: Kinematic alignment and its derivatives (rKA, iKA) seek to better replicate native joint morphology and tension, often reducing the need for soft tissue releases and improving functional outcomes compared to MA. rKA and iKA introduce protective boundaries to avoid extreme phenotypes and possible instability. FA leverages robotic platforms and integrates these principles with real-time gap balancing, demonstrating promise for consistent, personalized outcomes. Some reports, however, advise caution with adjusted Mechanical Alignment (aMA), particularly those that result in phenotypes such as Coronal Plane Alignment of the Knee (CPAK) VII or VIII, which may increase the risk of revision. Conclusions: The philosophy of TKA has evolved from a uniform mechanical target (MA) to a more nuanced, patient-specific strategy. While promising mid- to long-term outcomes and comparable survival data support the viability of KA and its derivatives, critical needs remain, including standardizing nomenclature (especially for FA) and conducting high-quality comparative trials. Future directions involve leveraging high-volume intraoperative data and Artificial Intelligence (AI) to refine decision-making and further personalize alignment strategies, without compromising long-term implant survivorship.

29 April 2025 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
KLKwong Weng Loh
Kwong Weng Loh
KAKhairul Anwar Anwar Ayob
Khairul Anwar Anwar Ayob
FHFAHRUDIN CHE HAMZAH
FAHRUDIN CHE HAMZAH
AMAzhar Mahmood Merican
Azhar Mahmood Merican
SSShahrul Hisham Sulaiman
Shahrul Hisham Sulaiman
STSei Kern Tiew
Sei Kern Tiew

3 September 2023 in International Journal of Infectious Diseases
Verified
Journal Article
Open access
STST Tay
ST Tay
AMAzhar Mahmood Merican
Azhar Mahmood Merican
KJKartini Abdul Jabar
Kartini Abdul Jabar
RVRukumani Devi Velayuthan
Rukumani Devi Velayuthan
KAKhairul Anwar Anwar Ayob
Khairul Anwar Anwar Ayob
RKRina Karunakaran
Rina Karunakaran
We report the isolation of a rare Gram-positive coccobacillary bacterium from synovial fluids of a patient with periprosthetic joint infection on three occasions over an 8-month period. As routine microbiological methods were not able to identify the isolate definitely, sequence analyses of the bacterial 16S ribosomal RNA gene and whole genome were performed. Analysis of the bacterial 16S ribosomal RNA gene showed the highest similarity (98.1%) with that of Falsarthrobacter (previously known as Arthrobacter) nasiphocae, which was first isolated from the nasal cavities of common seals (Phoca vitulina). The genome size of the strain (designated as UM1) is 2.4 Mb. With a high G+C content (70.4 mol%), strain UM1 is phylogenetically most closely related to F. nasiphocae based on whole genome analysis. Strain UM1 was susceptible to vancomycin, linezolid, trimethoprim-sulfamethoxazole, doxycycline, and intermediate to penicillin and ciprofloxacin. Ceftriaxone resistance was noted. The patient who was also on hemodialysis for his end stage kidney disease died approximately 3 weeks following implant removal and fusion with an external fixator. This study describes the first isolation of F. nasiphocae from human clinical samples. The use of emerging technologies has supported more definitive etiological diagnosis associated with rarely encountered organisms in periprosthetic joint infection.

1 July 2025 in Joint Diseases and Related Surgery
Verified
Journal Article
Open access
KLKwong Weng Loh
Kwong Weng Loh
KAKhairul Anwar Anwar Ayob
Khairul Anwar Anwar Ayob
AAAzlina Amir Abbas
Azlina Amir Abbas
VSVeenesh Selvaratnam
Veenesh Selvaratnam
Periprosthetic joint infection (PJI) remains a challenging complication following total hip arthroplasty (THA), commonly managed through a two-stage revision which can lead to significant morbidity. In this article, we present a rare case of Salmonella enteritidis PJI, initially presenting as prosthetic hip dislocation. Preoperative hip aspiration utilizing blood culture bottles enabled early identification of the organism and guided targeted antimicrobial therapy. The patient underwent revision THA using a well-fixed custom-made articulating spacer (CUMARS) construct, with targeted antibiotic-loaded bone cement. One-year follow-up demonstrated successful eradication of the infection, stable implant fixation, and good functional outcomes. In conclusion, this case underscores the importance of diagnostic hip aspiration and highlights the potential of the CUMARS technique as an effective and durable solution for managing rare PJIs caused by atypical organisms such as Salmonella enteritidis.

1 January 2024 in Acta Orthopaedica et Traumatologica Turcica
Verified
Journal Article
Open access
JSJong Keun Seon
Jong Keun Seon
KAKhairul Anwar Anwar Ayob
Khairul Anwar Anwar Ayob
Myung-giun NohMyung-giun Noh
Myung-giun Noh
HYHong Yeol Yang
Hong Yeol Yang
Oxidized zirconium (OxiniumTM) prostheses, made up of a metallic alloy of zirconium with a ceramic surface formed by oxidizing the outer layer, were developed as an alternative bearing surface to reduce polyethylene wear and decrease failure of total knee arthroplasty (TKA). We report a unique catastrophic failure of an Oxinium TKA with consequent accelerated wear and severe metallosis. Intraoperatively, we observed extensive wear grooving of the femoral component with exposure of the underlying silver layers and the complete wear of polyethylene on the medial side. Metallic debris had a peculiar arthrogram appearance, noted within the cut surface of the femur and tibia, indicative of the osteolysis that occurred, leading up to the failure of the implants. The histopathologic examination revealed a collection of macrophages with foreign-body reactions and black-pigmented metal-induced wear particles. Oxinium has clear benefits regarding superior wear properties; however, surgeons need to be aware that there is a risk of exposure to the underlying layers that may precede accelerated wear, deformation, and metallosis. Uncovering the deeper layers could result in the appearance of an arthrogram on plain radiographs. Early identification of polyethylene wear and prompt revision is crucial to avoid the rapid progression of subsequent metallosis and catastrophic implant failure, specifically when using oxidized zirconium components for TKA. To the best of our knowledge, this is the first report presenting a detailed histologic analysis to provide insight into the mechanisms of the failed Oxinium components. Cite this article as: Keun Seon J, Anwar Ayob K, Giun Noh M, Yeol Yang H. Peculiar reaction of oxidized zirconium from a total knee arthroplasty prosthesis: A case report. Acta Orthop Traumatol Turc., 2024;58(1):68-72.