Magnetostrictive transduction has been widely utilized in nondestructive evaluation (NDE) applications, specifically for the generation and reception of guided waves for the long-range inspection of components such as pipes, vessels, and small tubes. Transverse-motion guided wave modes (e.g., torsional vibrations in pipes) are the most common choice for long-range inspection applications, because the wave motion is in the plane of the structure surface, and therefore does not couple well to the surrounding material. Magnetostrictive-based sensors for these wave modes using the Wiedemann effect have been available for several years. An alternative configuration of a sensor for generating and receiving these transverse-motion guided waves swaps the biasing and time-varying magnetic field directions. This alternative design is a reversed Wiedemann effect magnetostrictive transducer. These transducers exhibit a number of unique features compared with the more conventional Wiedemann sensor, including: (1) the use of smaller rare earth permanent magnets to achieve large, uniform, and self-sustained bias field strengths; (2) the use of more efficient electric coil arrangements to induce a stronger time-varying magnetic field for a given coil impedance; (3) beneficial non-linear operating characteristics, given the efficiency improvements in both magnetic fields; and (4) the ability to generate unidirectional guided waves when the field arrangement is combined with a magnetically soft ferromagnetic strip (patch). Reversed Wiedemann effect magnetostrictive transducers will be presented that are suitable for different inspection applications, one using electromagnetic generation and reception directly in a ferromagnetic material, and another design that integrates a magnetostrictive patch to improve its efficiency and enable special operating characteristics.
Guided wave inspection technology is most often applied as a survey tool for pipeline inspection, where relatively low frequency ultrasonic waves, compared to those used in conventional ultrasonic nondestructive evaluation (NDE) methods, propagate along the structure; discontinuities cause a reflection of the sound back to the sensor for flaw detection. Although the technology can be used to accurately locate a flaw over long distances, the flaw sizing performance, especially for flaw depth estimation, is much poorer than other, local NDE approaches. Estimating flaw depth, as opposed to other parameters, is of particular interest for failure analysis of many structures. At present, most guided wave technologies estimate the size of the flaw based on the reflected signal amplitude from the flaw compared to a known geometry reflection, such as a circumferential weld in a pipeline. This process, however, requires many assumptions to be made, such as weld geometry and flaw shape. Furthermore, it is highly dependent on the amplitude of the flaw reflection, which can vary based on many factors, such as attenuation and sensor installation. To improve sizing performance, especially depth estimation, and do so in a way that is not strictly amplitude dependent, this paper describes an approach to estimate the depth of a flaw based on a multimodal analysis. This approach eliminates the need of using geometric reflections for calibration and can be used for both pipeline and plate inspection applications. To verify the approach, a test set was manufactured on plate specimens with flaws of different widths and depths ranging from 5% to 100% of total wall thickness; 90% of these flaws were sized to within 15% of their true value. A description of the initial multimodal sizing strategy and results will be discussed.
Aboveground storage tanks are used to store various fluids and chemicals for many industrial purposes. According to API standard 653, the structural integrity of these tanks must be regularly assessed. The U.S. EPA requires each operator to have a Spill Prevention, Control and Countermeasure Plan (SPCC) for aboveground storage containers. The accepted practice for inspection of these tanks, particularly the tank bottoms, requires removing the tank from service, emptying the tank, and interior entry for direct inspection of the structure. The required inspection operations are hazardous due to the chemicals themselves as well as the requirement to operate within confined spaces. An inspection from outside the tank would have significant cost and time benefits and would provide a large reduction in the risks faced by inspection personnel. Guided wave (GW) testing is a promising candidate for screening of storage tank walls and bottoms from the tank exterior due to the ability of GWs to propagate over long distances from a fixed probe location. The lowest-order transverse-motion guided wave modes (e.g., torsional vibrations in pipes) are a good choice for long-range inspection because this mode is not dispersive; therefore, the wave packets do not spread out in time. A common weakness of guided wave inspection is the complexity of report generation in the presence of multiple geometry features in the structure, such as welds, welded plate corners, attachments and so on. In some cases, these features cause generation of non-relevant indications caused by mode conversion. Another significant challenge in applying GW testing is development of probes with high-enough signal amplitudes and relatively small footprints to allow them to be mounted on short tank bottom extensions. In this paper, a new generation of magnetostrictive transducers will be presented. The transducers are based on the reversed Wiedemann effect and can generate shear horizontal mode guided waves over a wide frequency range (20–150 kHz) with SNRs in excess of 50 dB. The recently developed SwRI MST 8 × 8 probe contains an array of eight pairs of individual magnetostrictive transducers (MsTs). The data acquisition hardware allows acquisition using Full Matrix Capture (FMC) and analysis software reporting of anomalies based on Total Focusing Method (TFM) image reconstruction. This novel inspection package allows generation of reports that map out corrosion locations and provide estimates of defect widths. Case studies of this technology on actual storage tank walls and bottoms will be presented together with validation of processing methods on mockups with known anomalies and geometry features.
Above ground storage tanks are used to store various fluids and chemicals for many industrial purposes. According to API standard 653, the structural integrity of these tanks must be regularly assessed. The U.S. EPA requires each operator to have a Spill Prevention, Control and Countermeasure Plan (SPCC) for aboveground storage con-tainers. The accepted practice for inspection of these tanks, particularly the tank bot-toms, involves removing the tank from service, emptying the tank, and inspecting di-rectly from the interior. The required inspection operations are hazardous due to the chemicals themselves as well as the requirement to operate within confined spaces. An inspection from outside the tank would have significant cost and time benefits and would provide a large reduction in the risks faced by the inspection personnel. Guided wave (GW) testing is one promising candidate for screening of storage tanks walls and bottoms from the tank exterior due to the ability of GWs to propagate long distances from a fixed probe location. The lowest order transverse-motion guided wave modes (e.g., torsional vibrations in pipes) are a good choice for long-range inspection because this mode is not dispersive; therefore, the wave packets do not spread out in time. A common weakness of guided wave inspection is the complexity of report generation in the presence of multiple geometry features in the structure, such as welds, welded plate corners, attachments and so on. In some cases, these features cause generation of non-relevant indications due to mode conversion. Common non-relevant indications are described in this paper. Another significant challenge in applying GW testing is development of probes with high enough signal amplitudes and a relatively small footprint to allow them to be mounted on relatively short tank bottom extensions. In this paper a new generation of magnetostrictive transducers will be presented. The transducers are based on a reversed Wiedemann effect and can generate shear hori-zontal mode guided waves over a wide frequency range (20 – 150 kHz) and with SNR in excess of 50 dB. The recently developed SwRI MST 8x8 probe contains an array of 8 pairs of individual magnetostrictive transducers (MsTs). The data acquisition hard-ware allows acquisition using Full Matrix Capture (FMC) and analysis software re-porting of anomalies based on Total Focusing Method (TFM) image reconstruction. This novel inspection package allows generation of reports containing high accuracy corrosion mapping information. Case studies of this technology on actual storage tanks walls and bottoms will be presented together with validation of processing methods on mockups with known anomalies and geometry features.
1 September 2025 in e-Journal of Nondestructive Testing
Structural integrity of steel vessels is important for safe operation of any nuclear plant. Many of these structures have complicated geometry including concret....