This study deals with mathematical modeling and energy analysis of an ice rink cooling system with an underground thermal energy storage tank. The cooling system consists of an ice rink, chiller unit, and spherical thermal energy storage tank. An analytical model is developed for finding thermal performance of the cooling system. The model is based on formulations for transient heat transfer problem outside the thermal energy storage tank, for the energy needs of chiller unit, and for the ice rink. The solution of the thermal energy storage tank problem is obtained using a similarity transformation and Duhamel superposition techniques. Analytical expressions for heat gain of the ice rink and energy consumption of the chiller unit are derived as a function of inside design air, ambient air, and thermal energy storage tank temperatures. An interactive computer program in Matlab based on the analytical model is prepared for finding hourly variation of water temperature in the thermal energy storage tank, coefficient of performance of the chiller, suitable storage tank volume depending on ice rink area, and timespan required to attain an annually periodic operating condition. Results indicate that operation time of span 6–7 years will be obtained periodically for the system during 10 years operating time.
7 June 2022 in The European Journal of Research and Development
In this study, the thermal energy performances and environmental effects of two different reinforced concrete structures, Pure Shear Wall (PSW) Building and Shear Wall-Frame (SWF) Building, were investigated in the climatic conditions of Elazig province. Thermal performance analysis for both buildings; was carried out with the TS 825 program. First of all, through this program, monthly and annual heating loads were determined for 11 different alternative building component scenarios of two different buildings. Subsequently, efficiency alternatives were created in accordance with the climatic conditions of the region and TS 825. Efficiency alternatives designed for both buildings have been analyzed together with their completely uninsulated and current states. Finally, buildings with reinforced concrete carrier systems, energy analysis methods and efficiency alternatives were compared and evaluated based on the results of the analysis. As a result, it has been observed that the building with the PSW system consumes more energy than the building with the SWF system when it is uninsulated and in its current condition.