Ekaterina Zernitckaia

Dr. Ekaterina Zernitckaia

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
VVVadim Veiko
Vadim Veiko
YKYuliya Karlagina
Yuliya Karlagina
EZEkaterina Zernitckaia
Ekaterina Zernitckaia
EEElena Egorova
Elena Egorova
Maxim RadaevMaxim Radaev
Maxim Radaev
GOGalina Odintsova
Galina Odintsova
Laser processing of dental implant surfaces is becoming a more widespread replacement for classical techniques due to its undeniable advantages, including control of oxide formation and structure and surface relief at the microscale. Thus, using a laser, we created several biomimetic topographies of various shapes on the surface of titanium screw-shaped implants to research their success and survival rates. A distinctive feature of the topographies is the presence of “µ-rooms”, which are special spaces created by the depressions and elevations and are analogous to the µ-sized room in which the osteocyte will potentially live. We conducted the comparable in vivo study using dental implants with continuous (G-topography with µ-canals), discrete (S-topography with μ-cavities), and irregular (I-topography) laser-induced topographies. A histological analysis performed with the statistical method (with p-value less than 0.05) was conducted, which showed that G-topography had the highest BIC parameter and contained the highest number of mature osteocytes, indicating the best secondary stability and osseointegration.

2 October 2025 in Journal of Maxillofacial and Oral Surgery
Verified
Journal Article
Open access
PDF file
EZEkaterina Zernitckaia
Ekaterina Zernitckaia
JLJaime L. Lozada
Jaime L. Lozada
AYA. I. Yaremenko
A. I. Yaremenko
ARA. P. Reutova
A. P. Reutova
MMM. A. Markova
M. A. Markova
Zhanna LyutovaZhanna Lyutova
Zhanna Lyutova
Introduction: Modern maxillofacial surgery increasingly emphasizes the restoration and regeneration of oral tissues, particularly the hard tissues of the jaws. Bone defects may arise from disease, trauma, or congenital anomalies. Guided bone regeneration (GBR) using barrier membranes is a widely accepted technique for managing such defects. However, standard titanium and PTFE membranes require a secondary surgical procedure for removal, limiting their clinical convenience. Although resorbable collagen membranes avoid this issue, they often lack sufficient structural integrity, making them less effective for vertical or complex bone augmentation. Aim: This study aimed to evaluate the physicochemical properties of biodegradable membranes based on polylactic acid (PLA), its copolymers, and composite materials for potential use in GBR. In addition, the effects of sterilizing doses of ionizing radiation were assessed to determine an optimal sterilization protocol. Materials and Methods: The materials tested included pure PLA, PLA reinforced with hydroxyapatite (PLA/HAP), and polyglycolic acid (PLGA) in two compositions: 85:15 and 60:40. Physicochemical properties and responses to electron beam sterilization (25 kGy) were analyzed. Biodegradation was evaluated in phosphate-buffered saline at 37 °C. Sample morphology and molecular structure were assessed using infrared (IR) spectroscopy and scanning electron microscopy (SEM). Results: After one month, PLGA (60:40) samples exhibited approximately 40% mass loss, while PLGA (85:15) showed only about 5%. Pure PLA remained largely intact, with less than 1% mass loss. Non-irradiated PLA/HAP samples degraded inconsistently, with mass loss ranging from negligible to 19%, while irradiated PLA/HAP samples exhibited minimal degradation (up to 2%). This increased stability may be due to radiation-induced crystallinity, though further investigation is needed. In some cases, a slight mass increase was observed, possibly due to water diffusion into deeper composite layers. Among all tested materials, pure PLA demonstrated the highest stability, retaining its shape and showing minimal degradation throughout the study period. Conclusion: The results support the potential use of PLA and its copolymers for developing biodegradable membranes in GBR. Ionizing radiation appears to be a viable sterilization method, with minimal impact on material integrity. Further optimization of physicochemical properties and degradation behavior is warranted to facilitate clinical application in maxillofacial surgery.

21 April 2016
Verified
Conference Paper
Closed access
PDF file
GAGregory B. Altshuler
Gregory B. Altshuler
Andrey Vyacheslavovitch BelikovAndrey Vyacheslavovitch Belikov
Andrey Vyacheslavovitch Belikov
KSKsenia V. Shatilova
Ksenia V. Shatilova
AYAndrey I. Yaremenko
Andrey I. Yaremenko
AZAlexander Y. Zernitskiy
Alexander Y. Zernitskiy
EZEkaterina Zernitckaia
Ekaterina Zernitckaia

16 May 2020 in Parodontologiya
Verified
Journal Article
Closed access
PDF file
AYA. I. Yaremenko
A. I. Yaremenko
AZA. Yu. Zernitskiy
A. Yu. Zernitskiy
SKS. I. Kutukova
S. I. Kutukova
EZEkaterina Zernitckaia
Ekaterina Zernitckaia
ASA. I. Stolyarova
A. I. Stolyarova
АЗА. Ю. Зерницкий
А. Ю. Зерницкий
Relevance. Fractional laser technologies are very popular. The ability to create microchannels (coagulation or ablative nature) in the tissue by laser radiation stimulating its regeneration is the basis of fractional technology. The histological structure of the rabbit parietal bone during its regeneration after Laser Patterned Microcoagulation treatment was investigated by hematoxylin and eosin (H&E) stain.Purpose. This in vivo study investigated the regeneration of the rabbit’s parietal bone after fractional laser treatment using diode lasers with wavelengths 980 nm and 1550 nm.Materials and methods. A study was performed on the bone tissue of 10 laboratory animals (rabbits) using laser fractional treatment with wavelengths 1.55 and 0.98 μm. As laboratory animals (rabbits) were used Soviet chinchillas weighing 2.5-3 kg. 2 different lasers were used: FONALaser (Sirona Dental Systems, Germany) with a wavelength of 980 nm, a power of 5 W and a laser surgical device (LSP “IRE-Polyus”, Russia) with a wavelength of 1550 nm, a power of 25 W and a pulse width range from 60 to 250 ms.Results. On day 21, the thickness of the periosteum in the group with a wavelength of 980 nm did not significantly differ from the thickness of the periosteum in the group with a wavelength of 1550 nm – p = 0.4000. On the 45th day of observation, there were also no significant differences in the thickness of the periosteum between both groups – p = 0.2000.Conclusion. It was shown that the most destruction processes were noted by laser with a wavelength 1550 nm in the experiment without periosteum. The smallest changes were noted by laser with a wavelength 980 nm in the presence of periosteum. In this study, in 6 cases out of 10, the formation of young bone tissue as thin strip form at the bottom of the lesion site was noted.

29 June 2023 in Optical and Quantum Electronics
Verified
Journal Article
Closed access
PDF file
YKYuliya Karlagina
Yuliya Karlagina
ASAndrey Aleksandrovich Shelemanov
Andrey Aleksandrovich Shelemanov
VZV. Zilberman
V. Zilberman
EZEkaterina Zernitckaia
Ekaterina Zernitckaia
ELE. Lovushkina
E. Lovushkina
GOG. Odintsova
G. Odintsova

1 January 2026 in Case Reports in Dentistry
Verified
Journal Article
Open access
GKGurgen V. Khachatrian
Gurgen V. Khachatrian
JLJaime L. Lozada
Jaime L. Lozada
RHRobert A. Handysides
Robert A. Handysides
EZEkaterina Zernitckaia
Ekaterina Zernitckaia
Tooth autotransplantation is a biologically favorable option for the replacement of missing teeth and has demonstrated predictable outcomes with both immature and mature donor teeth. In challenging anterior maxillary defects, digitally assisted variations of the technique may expand treatment possibilities and offer an alternative to conventional bone augmentation in selected cases. This article presents a digital and clinical workflow for dentoalveolar complex (DAC) autotransplantation in anterior maxillary reconstruction. The reported case involves transplantation of a donor tooth together with its surrounding alveolar bone segment to compensate for a severe site deficiency. Virtual planning, guided osteotomy, and 3D‐printed replicas were used to optimize donor tooth assessment, recipient site preparation, and extraoral handling efficiency. These digital tools facilitated accurate positioning of the DAC and improved procedural predictability. The case demonstrated uneventful healing, preservation of soft and hard tissue contours, and no clinical signs of ankylosis or significant replacement resorption during follow‐up. This report suggests that digitally guided DAC autotransplantation may represent a viable treatment option for selected anterior defects where conventional approaches, including bone grafting or implant therapy, present biological or anatomical limitations.