Jian Yin

Dr. Jian Yin

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2019 in IEEE Access
Verified
Journal Article
Open access
JHJiatu Hong
Jiatu Hong
JYJian Yin
Jian Yin
Yitao LiuYitao Liu
Yitao Liu
JPJianchun Peng
Jianchun Peng
HJHui Jiang
Hui Jiang

6 August 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JYJian Yin
Jian Yin
JLJian Lu
Jian Lu
Yitao LiuYitao Liu
Yitao Liu
JPJianchun Peng
Jianchun Peng
HJHui Jiang
Hui Jiang
The transient performance during power reversal in a bidirectional dual active bridge (DAB) dc–dc converter usually suffers from the issues of current deviation, hard switching, and other induced problems. In this article, a novel phase-shift method for fast power reversal in a DAB converter is proposed, which can achieve transient zero voltage switching (ZVS) without dc current bias, and therefore, shows advanced transient performance. The detailed algorithms and the effective phase-shift ranges based on different voltage conversion ratios are elaborated. An error analysis of the performance of dc bias elimination is provided to evaluate probable errors within allowed tolerances. Extensive and comparative experimental results are provided to support the validity of the proposed phase-shift method. It is shown that smooth, fast, and reliable power reversal can be effectively achieved with the novel method, and there is no need to add snubbers into the circuit by virtue of transient ZVS.

25 October 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JYJian Yin
Jian Yin
XHXiaochao He
Xiaochao He
JLJian Lu
Jian Lu
HCHenry Shu Hung CHUNG
Henry Shu Hung CHUNG
Determining how to efficiently obtain superior transient response under both unidirectional power-changing and power-reversing operations in a bidirectional dual-active-bridge (DAB) dc/dc converter is a challenging problem. The traditional direct phase-shifting scheme would induce a transient dc current bias in the high-frequency link of the DAB, and therefore, lead to some adverse issues, such as magnetic saturation and increased current stress. In addition, the ac transient can propagate to the dc terminates and give rise to a worse transient response in a closed-loop control system. In this article, a fast phase-shift control is proposed that can execute all the possible power changes in a unified manner. By properly operating the primary bridge with pulsewidth modulation (PWM) and the secondary bridge with pulse frequency modulation (PFM), the DAB converter can complete the phase-shifting operation fast without a dc current bias in the ac link. A closed-loop control based on the hybrid PWM/PFM is further designed to regulate the primary dc current with improved transient performance. Since both PWM and PFM are standard, the whole control algorithm can be implemented efficiently in practical applications. The experimental results are provided to show that the power of the DAB converter can be governed bidirectionally with the proposed phase-shift control. The dc-terminal current can be changed to both polarities with fast transient and no apparent overshoot or oscillation.

13 February 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Yitao LiuYitao Liu
Yitao Liu
XZXudong Zhang
Xudong Zhang
ZLZijian Lu
Zijian Lu
JYJian Yin
Jian Yin
Numerous harmonics and electromagnetic interference (EMI) noise are prevalent in inverter system, potentially compromising output power quality. Harmonic and EMI filters serve as crucial components for mitigating harmonic distortion and EMI noise in grid-connected inverter. Nonetheless, these filters significantly increase the overall weight and volume of the inverter system, so there is a need to reduce their size and weight. This article uses planar magnetic integration technology to integrate the inductors of the LCL filter, the inductors of the passive EMI filter and the sampling coil of the active EMI filter into a single magnetic core unit through reasonable design of the PCB windings. Additionally, capacitance integration is facilitated by the insertion of dielectric material between planar coil layers. This innovative approach effectively reduces the size and weight of the filter, consequently elevating the power density of the inverter system. The planar magnetic integrated LCL-EMI hybrid filter is analyzed using a single-phase Gallium-Nitride (GaN) inverter simulation and experimental platform, demonstrating that the design scheme reduces the size and weight of the filter while ensuring harmonic and EMI suppression. The feasibility of the planar magnetic integration scheme is thereby verified.

14 June 2021 in IEEE Access
Verified
Journal Article
Open access
JYJian Yin
Jian Yin
JLJian Lu
Jian Lu
HJHui Jiang
Hui Jiang
Yitao LiuYitao Liu
Yitao Liu
JPJianchun Peng
Jianchun Peng
The scattered resistive elements residing in a dual-active-bridge (DAB) dc/dc converter can adversely affect its transient performance especially when the load change is large. Conventional phase-shift methods do not take the resistive impact into account in their modeling and analysis. In this paper, a comprehensive analysis of the detrimental influence on the transient performance of a DAB converter due to resistive elements is presented, based on which a modified phase-shift scheme is proposed to further optimize the transient response of the converter. A DAB prototype is designed to verify the resistive impact discussed and validate the proposed phase-shift scheme. The experimental results confirm that better transient response can be effectively achieved with the proposal.

19 December 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
WLWeihua Liang
Weihua Liang
Yitao LiuYitao Liu
Yitao Liu
YSYongpeng Shen
Yongpeng Shen
JYJian Yin
Jian Yin
An improved amplitude-domain (IAD-PWM) technique with minimum inductor current ripple for a three-phase quasi-Z-source inverter (qZSI) is proposed in this paper. The existing amplitude-domain technique expresses the three-phase voltage in a two-dimensional Cartesian coordinate system and divides the shoot-through time into several equal parts and inserts them in the switching sequence. However, this limits the scope and requires two large inductors to limit the inductor current ripple, resulting in a large volume and weight of the qZS inverter. The proposed IAD-PWM for the qZS inverter performs shoot-through behavior based on the geometric representation of the three-phase output voltage ranges in coordinate axes. Then, the shoot-through state time is divided into six unequal parts based on the discharging inductor current ripple, to achieve the minimum qZS inductor current ripples. The advantages of the proposed IAD-PWM lie in its extreme simplicity, as there is no shoot-through reference, and it avoids the complexity of vector and trigonometric functions calculations, while also having the capability to reduce qZS inductor current ripples or use smaller inductor in the qZSI, resulting in increasing of the whole system's power density. Moreover, the relationship among v a , v b and v c could be presented visually. The principle and the derivation of the proposed IAD-PWM are presented in detail, and the inductor current ripple under the proposed IAD-PWM and traditional ZSVM-6 are compared. Simulation and experimental results verify the outstanding features of the proposed IAD-PWM.