Bahetihazi Maidu

Mr. Bahetihazi Maidu

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2023 in Arrhythmia and Electrophysiology Review
Verified
Journal Article
Open access
PDF file
YCYaacoub Chahine
Yaacoub Chahine
MMMatthew J Magoon
Matthew J Magoon
BMBahetihazi Maidu
Bahetihazi Maidu
JÁJuan C del Álamo
Juan C del Álamo
PBPatrick M Boyle
Patrick M Boyle
NANazem Akoum
Nazem Akoum
Stroke is a leading cause of death worldwide. With escalating healthcare costs, early non-invasive stroke risk stratification is vital. The current paradigm of stroke risk assessment and mitigation is focused on clinical risk factors and comorbidities. Standard algorithms predict risk using regression-based statistical associations, which, while useful and easy to use, have moderate predictive accuracy. This review summarises recent efforts to deploy machine learning (ML) to predict stroke risk and enrich the understanding of the mechanisms underlying stroke. The surveyed body of literature includes studies comparing ML algorithms with conventional statistical models for predicting cardiovascular disease and, in particular, different stroke subtypes. Another avenue of research explored is ML as a means of enriching multiscale computational modelling, which holds great promise for revealing thrombogenesis mechanisms. Overall, ML offers a new approach to stroke risk stratification that accounts for subtle physiologic variants between patients, potentially leading to more reliable and personalised predictions than standard regression-based statistical associations.

12 December 2024 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
BMBahetihazi Maidu
Bahetihazi Maidu
PMPablo Martinez-Legazpi
Pablo Martinez-Legazpi
MGManuel Guerrero-Hurtado
Manuel Guerrero-Hurtado
CNCathleen M. Nguyen
Cathleen M. Nguyen
AGAlejandro Gonzalo
Alejandro Gonzalo
JAJuan C. del Alamo
Juan C. del Alamo

15 April 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
BMBahetihazi Maidu
Bahetihazi Maidu
PMPablo Martinez-Legazpi
Pablo Martinez-Legazpi
MGManuel Guerrero-Hurtado
Manuel Guerrero-Hurtado
CNCathleen M. Nguyen
Cathleen M. Nguyen
AGAlejandro Gonzalo
Alejandro Gonzalo
JAJuan C. del Alamo
Juan C. del Alamo
Intraventricular vector flow mapping (VFM) is a growingly adopted echocardiographic modality that derives time-resolved two-dimensional flow maps in the left ventricle (LV) from color-Doppler sequences. Current VFM models rely on kinematic constraints arising from planar flow incompressibility. However, these models are not informed by crucial information about flow physics; most notably the pressure and shear forces within the fluid and the resulting accelerations. This limitation has rendered VFM unable to combine information from different time frames in an acquisition sequence or derive fluctuating pressure maps. In this study, we leveraged recent advances in artificial intelligence (AI) to develop AI-VFM, a vector flow mapping modality that uses physics-informed neural networks (PINNs) encoding mass conservation and momentum balance inside the LV, and no-slip boundary conditions at the LV endocardium. AI-VFM recovers the flow and pressure fields in the LV from standard echocardiographic scans. It performs phase unwrapping and recovers flow data in areas without input color-Doppler data. AI-VFM also recovers complete flow maps at time points without color-Doppler input data, producing super-resolution flow maps. We show that informing the PINNs with momentum balance is essential to achieving temporal super-resolution and significantly increases the accuracy of AI-VFM compared to informing the PINNs only with mass conservation. AI-VFM is solely informed by each patient’s flow physics; it does not utilize explicit smoothness constraints or incorporate data from other patients or flow models. AI-VFM takes 15 minutes to run in off-the-shelf graphics processing units and its underlying PINN framework could be extended to map other flow-associated metrics like blood residence time or the concentration of coagulation species.

3 November 2026 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Closed access
LSLauren Severance
Lauren Severance
FCFrancisco Contijoch
Francisco Contijoch
IMImran Mahmud
Imran Mahmud
TBTaylor Buchalla
Taylor Buchalla
FHFrederick Han
Frederick Han
EMElliot R. McVeigh
Elliot R. McVeigh

3 April 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
BMBahetihazi Maidu
Bahetihazi Maidu
AGAlejandro Gonzalo
Alejandro Gonzalo
MGManuel Guerrero-Hurtado
Manuel Guerrero-Hurtado
CBClarissa Bargellini
Clarissa Bargellini
PMPablo Martinez-Legazpi
Pablo Martinez-Legazpi
JAJuan C. del Alamo
Juan C. del Alamo
Atrial fibrillation (AF) promotes blood stasis and thrombus formation, most often within the left atrial appendage (LAA), and can lead to stroke or transient ischemic attack (TIA). Time-resolved contrast-enhanced computed tomography (4D CT) captures left atrial (LA) opacification and washout, but it does not directly provide quantitative stasis metrics such as blood residence time. Patient-specific computational fluid dynamics (CFD) can quantify LA/LAA residence time, yet routine clinical use is limited by computational cost and sensitivity to patient-specific boundary conditions. Here, we present two complementary approaches to infer time-resolved 3D residence time fields directly from contrast dynamics. First, a physics-informed neural network (PINN) treats contrast as a passive scalar and jointly reconstructs velocity and residence time by enforcing the incompressible Navier–Stokes equations and transport equations for contrast concentration and residence time in moving, patient-specific LA anatomies. Second, an indicator dilution theory (IDT) formulation computes voxelwise, time-resolved residence time maps from contrast time curves alone by constructing a PV-referenced impulse response and modeling transport with a tank-in-series model with spatially dependent parameters. Both methods are benchmarked against patient-specific CFD in six cases spanning diverse LA function, including three patients with TIA or thrombus in the LAA and three patients free of events. Both approaches reproduce expected spatial and temporal trends, with higher residence time in the distal LAA and higher LAA residence time in cases with TIA or thrombus. IDT demonstrates the closest agreement with CFD across the full range of residence times and produces maps in seconds, facilitating clinical translation. In contrast, the PINN additionally recovers phase-dependent atrial flow structures, but tends to smooth and underestimate the highest residence-time regions and requires hours of training. Together, these results support a scalable workflow in which IDT enables rapid stasis screening from contrast CT, and PINNs provide a complementary pathway for detailed, patient-specific hemodynamic inference when full-field flow information is needed.

28 September 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
JAJuan C. del Alamo
Juan C. del Alamo
CNCathleen M. Nguyen
Cathleen M. Nguyen
MGManuel Guerrero-Hurtado
Manuel Guerrero-Hurtado
AKAdithan Kandasamy
Adithan Kandasamy
BMBahetihazi Maidu
Bahetihazi Maidu
PMPablo Martinez-Legazpi
Pablo Martinez-Legazpi
Vector flow mapping (VFM) reconstructs left-ventricular (LV) blood velocity from color-Doppler echocardiography by combining the measured beamwise component with physical and regularizing constraints. Analysis of the discrete VFM formulation shows that the inverse problem is intrinsically ill posed: the occurrence of singular modes can be predicted from the geometry of the segmented blood-pool domain, the imposed boundary conditions, and the degree of smoothing. These modes can propagate uncertainty along entire transverse bands of the reconstructed velocity field, yet conventional VFM neither quantifies this uncertainty nor allows for correcting the blood-pool segmentation. We introduce Bayesian VFM (B–VFM), a hierarchical framework that jointly infers radial and transverse velocities, a probabilistic blood-pool mask, their spatially resolved uncertainties, and hyperparameters weighting Doppler and segmentation fidelity, mass conservation, boundary conditions, and smoothness. The discretized posterior admits a closed-form gradient and exact Hessian, enabling computationally efficient, gradient-based MAP estimation, matrix-free Laplace sampling, and direct analysis of ill-posed modes. Posterior inference combines Gibbs sampling of conjugate Gamma-distributed hyperparameters with conditional maximum-a-posteriori estimation and a Laplace approximation for the high-dimensional velocity and mask fields. To accommodate systematic departures from planar mass conservation, B-VFM can learn the covariance of the planar divergence residual from an ensemble of flows and incorporate it as a structured model-discrepancy prior. Independent chains converged reproducibly, while covariance priors learned from flow ensembles illustrated how model discrepancies can be incorporated into the inference. B–VFM was evaluated using Lamb–Chaplygin dipoles under ideal conditions and with Doppler corruption, Doppler voids, and segmentation defects, and using the Hicks–Moffatt family of spherical vortices to assess violations of planar mass conservation. The method produced smooth reconstructions, localized uncertainty near unreliable measurements and regions of model inconsistency, and used flow information to correct segmentation errors. Within the tested vortex family, the data-informed planar divergence prior reduced velocity bias and mask distortion. B–VFM thus provides an uncertainty-aware reconstruction method and a flexible foundation for future VFM formulations incorporating additional priors, observations, and physical models. Future work will evaluate the method using clinical data and more complex three-dimensional benchmark flows.