Adithan Kandasamy

Adithan Kandasamy

Auto-generated profile, based on publicly available information

Adithan Kandasamy

Dept. of Mechanical Engineering, University of Washington, Seattle, WA, USA

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2025 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
AKAdithan Kandasamy
Adithan Kandasamy
YYYi-Ting Yeh
Yi-Ting Yeh
RSRicardo Serrano
Ricardo Serrano
MMMark Mercola
Mark Mercola
JAJuan C. del Alamo
Juan C. del Alamo
Traction Force Microscopy (TFM) is a versatile tool to quantify cell-exerted forces by imaging and tracking fiduciary markers embedded in elastic substrates. The computations involved in TFM are often ill-conditioned, and data smoothing or regularization is required to avoid overfitting the noise in the tracked displacements. Most TFM calculations depend critically on the heuristic selection of regularization (hyper-) parameters affecting the balance between overfitting and smoothing. However, TFM methods rarely estimate or account for measurement errors in substrate deformation to adjust the regularization level accordingly. Moreover, there is a lack of tools for uncertainty quantification (UQ) to understand how these errors propagate to the recovered traction stresses. These limitations make it difficult to interpret the TFM readouts and hinder comparing different experiments. This manuscript presents an uncertainty-aware TFM technique that estimates the variability in the magnitude and direction of the traction stress vector recovered at each point in space and time of each experiment. In this technique, a non-parametric bootstrap method perturbs the cross-correlation functional of Particle Image Velocimetry (PIV) to assess the uncertainty of the measured deformation. This information is passed on to a hierarchical Bayesian TFM framework with spatially adaptive regularization that propagates the uncertainty to the traction stress readouts (TFM-UQ). We evaluate TFM-UQ using synthetic datasets with prescribed image quality variations and demonstrate its application to experimental datasets. These studies show that TFM-UQ bypasses the need for subjective regularization parameter selection and locally adapts smoothing, outperforming traditional regularization methods. They also illustrate how uncertainty-aware TFM tools can be used to objectively choose key image analysis parameters like PIV window size. We anticipate that these tools will allow for decoupling biological heterogeneity from measurement variability and facilitate automating the analysis of large datasets by parameter-free, input data-based regularization.

27 August 2025 in Acta Biomaterialia
Verified
Journal Article
Closed access
AGAntoni Garcia-Herreros
Antoni Garcia-Herreros
YYYi-Ting Yeh
Yi-Ting Yeh
YTYunpeng Tu
Yunpeng Tu
AKAdithan Kandasamy
Adithan Kandasamy
JAJuan C. del Alamo
Juan C. del Alamo
ECErnesto Criado-Hidalgo
Ernesto Criado-Hidalgo

9 July 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
AKAdithan Kandasamy
Adithan Kandasamy
YYYi-Ting Yeh
Yi-Ting Yeh
RSRicardo Serrano
Ricardo Serrano
MMMark Mercola
Mark Mercola
JÁJuan C. del Álamo
Juan C. del Álamo
Traction Force Microscopy (TFM) is a versatile tool to quantify cell-exerted forces by imaging and tracking fiduciary markers embedded in elastic substrates. The computations involved in TFM are ill-conditioned, and data smoothing or regularization is required to avoid overfitting the noise in the tracked substrate displacements. Most TFM calculations depend critically on the heuristic selection of regularization (hyper)parameters affecting the balance between overfitting and smoothing. However, TFM methods rarely estimate or account for measurement errors in substrate deformation to adjust the regularization level accordingly. Moreover, there is a lack of tools to quantify how these errors propagate to the recovered traction stresses. These limitations make it difficult to interpret TFM readouts and hinder comparing different experiments. This manuscript presents an uncertainty-aware TFM technique that estimates the variability in the magnitude and direction of the traction stress vector recovered at each point in space and time of each experiment. In this technique, substrate deformation and its uncertainty are quantified using a non-parametric bootstrap PIV method by resampling the microscopy image pixels (PIV-UQ). This information is passed to a hierarchical Bayesian framework that automatically selects its hyperparameters to perform spatially adaptive regularization conditioned on image quality and propagates the uncertainty to the traction stress readouts (TFM-UQ). We validate the performance of PIV-UQ and TFM-UQ using synthetic datasets with prescribed image quality variations and demonstrate the application of PIV-UQ and TFM-UQ to experimental datasets. These studies show that TFM-UQ locally adapts the level of smoothing, outperforming traditional regularization methods. They also illustrate how uncertainty-aware TFM tools can be used to objectively choose key image analysis parameters like PIV-UQ interrogation window size. We anticipate that these tools will allow for decoupling biological heterogeneity from measurement variability and facilitate automating the analysis of large datasets by parameter-free, input data-based regularization.

28 September 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
JAJuan C. del Alamo
Juan C. del Alamo
CNCathleen M. Nguyen
Cathleen M. Nguyen
MGManuel Guerrero-Hurtado
Manuel Guerrero-Hurtado
AKAdithan Kandasamy
Adithan Kandasamy
BMBahetihazi Maidu
Bahetihazi Maidu
PMPablo Martinez-Legazpi
Pablo Martinez-Legazpi
Vector flow mapping (VFM) reconstructs left-ventricular (LV) blood velocity from color-Doppler echocardiography by combining the measured beamwise component with physical and regularizing constraints. Analysis of the discrete VFM formulation shows that the inverse problem is intrinsically ill posed: the occurrence of singular modes can be predicted from the geometry of the segmented blood-pool domain, the imposed boundary conditions, and the degree of smoothing. These modes can propagate uncertainty along entire transverse bands of the reconstructed velocity field, yet conventional VFM neither quantifies this uncertainty nor allows for correcting the blood-pool segmentation. We introduce Bayesian VFM (B–VFM), a hierarchical framework that jointly infers radial and transverse velocities, a probabilistic blood-pool mask, their spatially resolved uncertainties, and hyperparameters weighting Doppler and segmentation fidelity, mass conservation, boundary conditions, and smoothness. The discretized posterior admits a closed-form gradient and exact Hessian, enabling computationally efficient, gradient-based MAP estimation, matrix-free Laplace sampling, and direct analysis of ill-posed modes. Posterior inference combines Gibbs sampling of conjugate Gamma-distributed hyperparameters with conditional maximum-a-posteriori estimation and a Laplace approximation for the high-dimensional velocity and mask fields. To accommodate systematic departures from planar mass conservation, B-VFM can learn the covariance of the planar divergence residual from an ensemble of flows and incorporate it as a structured model-discrepancy prior. Independent chains converged reproducibly, while covariance priors learned from flow ensembles illustrated how model discrepancies can be incorporated into the inference. B–VFM was evaluated using Lamb–Chaplygin dipoles under ideal conditions and with Doppler corruption, Doppler voids, and segmentation defects, and using the Hicks–Moffatt family of spherical vortices to assess violations of planar mass conservation. The method produced smooth reconstructions, localized uncertainty near unreliable measurements and regions of model inconsistency, and used flow information to correct segmentation errors. Within the tested vortex family, the data-informed planar divergence prior reduced velocity bias and mask distortion. B–VFM thus provides an uncertainty-aware reconstruction method and a flexible foundation for future VFM formulations incorporating additional priors, observations, and physical models. Future work will evaluate the method using clinical data and more complex three-dimensional benchmark flows.