Fridon Shubitidze

Dr. Fridon Shubitidze

Dartmouth College, Thayer School of Engineering, 14 Engineering Dr. Hanover, NH 03755, USA
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2015 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
FSFridon Shubitidze
Fridon Shubitidze
KKKatsiaryna Kekalo
Katsiaryna Kekalo
RSRobert Stigliano
Robert Stigliano
IBIan Baker
Ian Baker
Magnetic nanoparticles (MNPs), referred to as the Dartmouth MNPs, which exhibit high specific absorption rate at low applied field strength have been developed for hyperthermia therapy applications. The MNPs consist of small (2–5 nm) single crystals of gamma-Fe2O3 with saccharide chains implanted in their crystalline structure, forming 20–40 nm flower-like aggregates with a hydrodynamic diameter of 110–120 nm. The MNPs form stable (>12 months) colloidal solutions in water and exhibit no hysteresis under an applied quasistatic magnetic field, and produce a significant amount of heat at field strengths as low as 100 Oe at 99–164 kHz. The MNP heating mechanisms under an alternating magnetic field (AMF) are discussed and analyzed quantitatively based on (a) the calculated multi-scale MNP interactions obtained using a three dimensional numerical model called the method of auxiliary sources, (b) measured MNP frequency spectra, and (c) quantified MNP friction losses based on magneto-viscous theory. The frequency responses and hysteresis curves of the Dartmouth MNPs are measured and compared to the modeled data. The specific absorption rate of the particles is measured at various AMF strengths and frequencies, and compared to commercially available MNPs. The comparisons demonstrate the superior heating properties of the Dartmouth MNPs at low field strengths (<250 Oe). This may extend MNP hyperthermia therapy to deeper tumors that were previously non-viable targets, potentially enabling the treatment of some of the most difficult cancers, such as pancreatic and rectal cancers, without damaging normal tissue.

7 August 2002 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
FSFridon Shubitidze
Fridon Shubitidze
KOK. O'NEill
K. O'NEill
SHS.A. Haider
S.A. Haider
KSKeli Sun
Keli Sun
KPK.D. Paulsen
K.D. Paulsen
The Method of Auxiliary Sources (MAS) is formulated and applied to solution of wide-band electromagnetic induction problems involving highly conducting and possibly permeable metallic objects. Improved remote sensing discrimination of buried unexploded ordnance (UXO) motivates the study. The method uses elementary auxiliary magnetic charges and magnetic current elements to produce the unknown field. Auxiliary sources are located on virtual surfaces that usually conform to but do not coincide with the real surface of the object. Once the source coefficients are determined, the-secondary field can easily be found. The method involves no confrontations with source or Green's function singularities. It is capable of treating penetrable as well as nonpenetrable objects. Because the solution is composed of fields that automatically satisfy the governing equations, by construction, all approximation resides only in the enforcement of boundary conditions at matching (collocation) points. Accuracy in satisfying the boundary conditions can be evaluated explicitly using noncollocation points over the surface. This in turn allows one to identify problem areas on the surface and make intelligent adjustments of the source distributions, to improve solutions at minimal cost. A general 3D formulation is presented, and a version specialized to treat bodies of revolution is applied in the specific test cases discussed.

1 January 2012 in International Journal of Biomedical Imaging
Verified
Journal Article
Open access
PDF file
PMPaul Meaney
Paul Meaney
FSFridon Shubitidze
Fridon Shubitidze
MFMargaret W. Fanning
Margaret W. Fanning
MKMaciej Kmiec
Maciej Kmiec
NENeil R. Epstein
Neil R. Epstein
KPKeith D. Paulsen
Keith D. Paulsen
Microwave imaging techniques are prone to signal corruption from unwanted multipath signals. Near-field systems are especially vulnerable because signals can scatter and reflect from structural objects within or on the boundary of the imaging zone. These issues are further exacerbated when surface waves are generated with the potential of propagating along the transmitting and receiving antenna feed lines and other low-loss paths. In this paper, we analyze the contributions of multi-path signals arising from surface wave effects. Specifically, experiments were conducted with a near-field microwave imaging array positioned at variable heights from the floor of a coupling fluid tank. Antenna arrays with different feed line lengths in the fluid were also evaluated. The results show that surface waves corrupt the received signals over the longest transmission distances across the measurement array. However, the surface wave effects can be eliminated provided the feed line lengths are sufficiently long independently of the distance of the transmitting/receiving antenna tips from the imaging tank floor. Theoretical predictions confirm the experimental observations.

10 March 2011 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
TGTomasz M. Grzegorczyk
Tomasz M. Grzegorczyk
BBBenjamin E. Barrowes
Benjamin E. Barrowes
FSFridon Shubitidze
Fridon Shubitidze
JFJuan Pablo Fernandez
Juan Pablo Fernandez
KOKevin O'Neill
Kevin O'Neill
The simultaneous detection and identification of multiple targets using electromagnetic induction (EMI) time-domain sensors remains a challenge due to the fast decay of the magnetic field with sensor-target distance. For example, the signal from a weak yet shallow target or clutter item can overshadow that from a much larger yet deeper unexploded ordnance (UXO), potentially resulting in erroneous localization and/or identification. We propose, in this paper, a method based on the Gauss-Newton algorithm for the inversion of multiple targets within the field of view of sensors operating at EMI frequencies (tens of hertz to a few hundred kilohertz). In order to minimize the number of unknowns to invert for, the polarizability tensor is written as a time-independent orientation matrix multiplied by a time-dependent diagonal intrinsic polarizability tensor. Similarly, position is supposed to be time independent so that both position and orientation angles are inverted only once using all time channels collected by the instrument. Moreover, using the dipole approximation, we are able to compute the Jacobian in closed form for instruments with either square or circular primary field coils, thus contributing to the speed of the algorithm. Validating results are shown based on the measurement data collected with two EMI sensors on various types of UXO.

20 July 2016 in International Journal of Hyperthermia
Verified
Journal Article
Closed access
RSRobert V. Stigliano
Robert V. Stigliano
FSFridon Shubitidze
Fridon Shubitidze
JPJames D. Petryk
James D. Petryk
LSLevan Shoshiashvili
Levan Shoshiashvili
APAlicia A. Petryk
Alicia A. Petryk
PHP. Jack Hoopes
P. Jack Hoopes
Background: Magnetic nanoparticle hyperthermia therapy is a promising technology for cancer treatment, involving delivering magnetic nanoparticles (MNPs) into tumours then activating them using an alternating magnetic field (AMF). The system produces not only a magnetic field, but also an electric field which penetrates normal tissue and induces eddy currents, resulting in unwanted heating of normal tissues. Magnitude of the eddy current depends, in part, on the AMF source and the size of the tissue exposed to the field. The majority of in vivo MNP hyperthermia therapy studies have been performed in small animals, which, due to the spatial distribution of the AMF relative to the size of the animals, do not reveal the potential toxicity of eddy current heating in larger tissues. This has posed a non-trivial challenge for researchers attempting to scale up to clinically relevant volumes of tissue. There is a relative dearth of studies focused on decreasing the maximum temperature resulting from eddy current heating to increase therapeutic ratio. Methods: This paper presents two simple, clinically applicable techniques for decreasing maximum temperature induced by eddy currents. Computational and experimental results are presented to understand the underlying physics of eddy currents induced in conducting, biological tissues and leverage these insights to mitigate eddy current heating during MNP hyperthermia therapy. Results: Phantom studies show that the displacement and motion techniques reduce maximum temperature due to eddy currents by 74% and 19% in simulation, and by 77% and 33% experimentally. Conclusion: Further study is required to optimise these methods for particular scenarios; however, these results suggest larger volumes of tissue could be treated, and/or higher field strengths and frequencies could be used to attain increased MNP heating when these eddy current mitigation techniques are employed.

22 February 2011 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JFJuan Pablo Fernandez
Juan Pablo Fernandez
BBBenjamin E. Barrowes
Benjamin E. Barrowes
TGTomasz M. Grzegorczyk
Tomasz M. Grzegorczyk
NLNicolas Lhomme
Nicolas Lhomme
KOKevin O'Neill
Kevin O'Neill
FSFridon Shubitidze
Fridon Shubitidze
The identification and discrimination of unexploded ordnance using low-frequency electromagnetic induction is an expensive and difficult process, typically beset by low data diversity and high positioning uncertainty. In this paper, we present the Man-Portable Vector (MPV) sensor, a new time-domain instrument designed to remedy these shortcomings by measuring all three vector components of the secondary magnetic field at five distinct points around each transmitter location. The MPV also has a laser positioning system that can give its location with millimeter precision. After describing the instrument in detail, we study its performance in various sets of measurements, using the tensor dipole model to analyze the data. We find that the sensor can detect deeply buried targets and identify some standard ordnance items. It can also resolve separate targets in cases where two objects share the field of view and produce overlapping signals. A new incarnation of the MPV, the MPV-II, is in an advanced stage of development.