23 June 2023 in IEEE Transactions on Nuclear Science
AC-Coupled LGAD (AC-LGAD) is a new 4D detector developed based on the Low Gain Avalanche Diode (LGAD) technology, which can accurately measure the time and spatial information of particles. The Institute of High Energy Physics (IHEP) designed a large-size AC-LGAD with a pitch of 2000 μm and AC pad of 1000 μm, and explored the effect of N+ layer dose on the spatial resolution and time resolution. The spatial resolution varied from 36 μm to 16 μm depending on N+ dose for a charge corresponding to about 12 minimum ionizing particles. The jitter component of the time resolution does not change significantly with different N+ doses, and it is about 15-17 ps measured by laser. The AC-LGAD with a low N+ dose has a large attenuation factor and better spatial resolution in the central region between pads. In these specific conditions, large signal attenuation factor and low noise level are beneficial to improve the spatial resolution of the AC-LGAD sensor.
16 July 2021 in IEEE Transactions on Nuclear Science
The thickness of the high-resistivity layer (active layer) is a crucial factor affecting the timing resolution of low gain avalanche diodes (LGADs). We studied the potential improvement of the timing resolution of charge particles based on LGADs with different active layer thicknesses. The Institute of High Energy Physics (IHEP) and the Novel Device Laboratory (NDL) jointly designed two types of LGAD sensors with active layer thicknesses of 33 and 50 $\mu \text{m}$ . The timing resolution is given by contributions from the time walk, jitter, and nonuniform charge deposition (Landau term). The jitter and the Landau term contributions in the timing resolution are extracted by the combination of the ${^{90}{Sr}}$ beta source test and the picosecond laser test. The Landau contribution is found to be the dominant contribution for both types of LGAD sensors, and the Landau contribution of the 33 $\mu \text{m}$ sensor is lower than that of the 50 $\mu \text{m}$ sensor. Based on the experimental results, we perform the simulation for thinner active layer LGAD with the WeightField2 program. The timing resolution can be further improved by reducing the active layer thickness from 33 to 20 $\mu \text{m}$ .
21 March 2022 in IEEE Transactions on Nuclear Science
Low-gain avalanche diode (LGAD) is the chosen technology for the ATLAS high-granularity timing detector (HGTD). According to previous studies, the acceptor removal effect due to the radiation and the single-event burnout (SEB) at high bias voltages are still a challenge for the LGAD. The Institute of High Energy Physics (IHEP), Beijing, China, cooperated with the Institute of Microelectronics (IME), Beijing, China, for the design and fabrication of the IHEP-IME LGAD sensors with shallow carbon and deep N++ layer to improve the radiation hardness of LGAD. After neutron irradiation up to $2.5 \times 10^{15}\,\,{\mathrm{ n}}_{\mathrm{ eq}}$ /cm 2 , the leakage current, the collected charge, and timing resolution of the three IHEP-IME sensors measured with a beta telescope setup meet the HGTD requirements ( $< 125~\mu \text{A}$ /cm 2 , >4 fC, and <70 ps). The LGAD sensor with shallow carbon had the lowest operation voltage after irradiation and is very promising to avoid the SEB effect. A sensor with a deep N++ layer increased the breakdown voltage of the LGAD with a high dopant concentration, which could alleviate the problem of the early breakdown of radiation-hard LGAD before irradiation.
10 November 2022 in IEEE Transactions on Nuclear Science
This paper presents a detailed investigation of the influence of carbon co-implantation on the radiation hardness of the Low Gain Avalanche Detectors (LGADs). The implantation and thermal annealing of carbon during LGAD fabrication could improve the device’s radiation hardness. As an attempt to explain the mechanism of the implanted carbon to suppress acceptor removal induced by neutron irradiation, the acceptor removal coefficients ( c factors) of LGADs are modeled based on Secondary Ion Mass Spectrometry (SIMS) which is used to study carbon and boron distributions in critical regions of LGADs. The model is in good agreement with the radiation hardness measurement of both sensors fabricated by the Institute of High Energy Physics (IHEP) and by others, revealing the reliability of the model in predicting the c factor without irradiating the sensors but with only density profiles of carbon and boron. This model is pivotal to the design of the next version of IHEP LGAD aiming at reaching better anti-radiation performance.
1 August 2021 in Journal of Instrumentation
23 February 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment