Hamoun Pourroshanfekr Arabani

Mr. Hamoun Pourroshanfekr Arabani

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2022 in Electronics
Verified
Journal Article
Open access
PDF file
MJMahshid Javidsharifi
Mahshid Javidsharifi
Hamoun Pourroshanfekr ArabaniHamoun Pourroshanfekr Arabani
Hamoun Pourroshanfekr Arabani
Tamás KerekesTamás Kerekes
Tamás Kerekes
Dezso SeraDezso Sera
Dezso Sera
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
A novel stochastic strategy for solving the problem of optimal power management of multi-microgrid (MMG) systems is suggested in this paper. The considered objectives are minimizing the total cost and emission of the system. The suggested algorithm is applied on a MMG consisting of four microgrids (MG), each including fossil fuel-based generator units, wind turbine (WT), photovoltaic (PV) panel, battery, and local loads. The unscented transformation (UT) method is applied to deal with the inherent uncertainties of the renewable energy sources (RES) and forecasted values of the load demand and electricity price. The proposed algorithm is applied to solve the power management of a sample MMG system in both deterministic and probabilistic scenarios. It is justified through simulation results that the suggested algorithm is an efficient approach in satisfying the minimization of the cost and the environmental objective functions. When considering uncertainties, it is observed that the maximum achievable profit is about 23% less than that of the deterministic condition, while the minimum emission level increases 22%. It can be concluded that considering uncertainties has a significant effect on the economic index. Therefore, to present more accurate and realistic results it is essential to consider uncertainties in solving the optimal power management of MMG system.

29 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
MJMahshid Javidsharifi
Mahshid Javidsharifi
Hamoun Pourroshanfekr ArabaniHamoun Pourroshanfekr Arabani
Hamoun Pourroshanfekr Arabani
Tamás KerekesTamás Kerekes
Tamás Kerekes
Dezso SeraDezso Sera
Dezso Sera
Sergiu SpataruSergiu Spataru
Sergiu Spataru
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Satisfying the mobile traffic demand in next generation cellular networks increases the cost of energy supply. Renewable energy sources are a promising solution to power base stations in a self-sufficient and cost-effective manner. This paper presents an optimal method for designing a photovoltaic (PV)-battery system to supply base stations in cellular networks. A systematic approach is proposed for determining the power rating of the photovoltaic generator and battery capacity from a technical and economical point of view in order to minimize investment cost as well as operational expenditure, while the power autonomy of the PV-battery system is maximized in a multi-objective optimization framework. The proposed method is applied to optimally size a photovoltaic-battery system for three cases with different availability of solar power to investigate the effect of environmental conditions. Problem-solving using the proposed approach leads to a set of solutions at different costs versus different levels of power autonomy. According to the importance of each criterion and the preference of decision-makers, one of the achieved solutions can be selected for the implementation of the photovoltaic-battery system to supply base stations in cellular networks.

22 November 2021 in Drones
Verified
Journal Article
Open access
PDF file
MJMahshid Javidsharifi
Mahshid Javidsharifi
Hamoun Pourroshanfekr ArabaniHamoun Pourroshanfekr Arabani
Hamoun Pourroshanfekr Arabani
Tamás KerekesTamás Kerekes
Tamás Kerekes
Dezso SeraDezso Sera
Dezso Sera
Sergiu SpataruSergiu Spataru
Sergiu Spataru
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
In order to provide Internet access to rural areas and places without a reliable economic electricity grid, self-sustainable drone-based cellular networks have recently been presented. However, the difficulties of power consumption and mission planning lead to the challenge of optimal sizing of the power supply for future cellular telecommunication networks. In order to deal with this challenge, this paper presents an optimal approach for sizing the photovoltaic (PV)-battery power supply for drone-based cellular networks in remote areas. The main objective of the suggested approach is to minimize the total cost, including the capital and operational expenditures. The suggested framework is applied to an off-grid cellular telecommunication network with drone-based base stations that are powered by PV-battery systems-based recharging sites in a rural location. The PV-battery system is optimally designed for three recharging sites with three different power consumption profiles with different peak and cumulative loads. Results show that the optimal design of the PV-battery system is dependent on geographical data, solar irradiation, and ambient temperature, which affect the output power of the PV system, as well as the power consumption profile, which affects the required number of PV panels and battery capacity.

4 February 2022 in Electricity
Verified
Journal Article
Open access
PDF file
MJMahshid Javidsharifi
Mahshid Javidsharifi
Hamoun Pourroshanfekr ArabaniHamoun Pourroshanfekr Arabani
Hamoun Pourroshanfekr Arabani
Tamás KerekesTamás Kerekes
Tamás Kerekes
Dezso SeraDezso Sera
Dezso Sera
Sergiu SpataruSergiu Spataru
Sergiu Spataru
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
In order to maximize the use of renewable-based distributed generators (DGs), in addition to dealing with the effects of the inherent power management uncertainties of microgrids (MGs), applying storage devices is essential in the electrical system. The main goal of this paper is to minimize the total operation cost as well as the emissions of MG energy resources, alongside the better utilization of renewable energy sources (RES) and energy storage systems. The uncertainties of wind speed, solar irradiation, market price and electrical load demand are modeled using reduced unscented transformation (RUT) method. Simulation results reveal that, as expected, by increasing the battery efficiency, the achievable minimum daily operational cost of the system is reduced. For example, with 93% battery efficiency, the operational cost equals EUR 9200, while for an efficiency of 97%, the achievable minimum daily operational cost is EUR 8900. Moreover, the proper economic/environmental performance of the suggested approach, which contributes to the possibility of selecting a compromise solution for the MG operator in accordance with technical and economic constraints, is justified.

16 September 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
MIMattias Ingelström
Mattias Ingelström
Hamoun Pourroshanfekr ArabaniHamoun Pourroshanfekr Arabani
Hamoun Pourroshanfekr Arabani
MAMats Alaküla
Mats Alaküla
FFFrancisco Jose Marquez Fernandez
Francisco Jose Marquez Fernandez
The rapid progression of the electrification of road transport in many countries urges the need to make informed decisions on the location and size of the required charging infrastructure. This article’s main contribution is a novel method to position fast-charging stations (FCSs) based on the transportation energy demand and to evaluate the performance of such charging infrastructure. Depending on their range and the availability of charging infrastructure, electric vehicles (EVs) may need to adjust their route patterns to include en-route charging. Understanding and planning for these adjustments can help assess future charging infrastructure needs more effectively. The proposed method introduces a detailed agent-based simulation procedure to track individual trucks assumed to be fully electric. The procedure allows for analyzing each vehicle’s and charging station’s specific power flows. A case study based on a one-to-one representation of Swedish long-haul road freight transport is created based on real-world data. The results demonstrate that, using the presented method, 90% of the Swedish long-haul truck fleet can be electrified with 26 carefully placed charging stations. These stations vary in size between 10 and 60 MW, presenting a utilization of 30%–53%. This article also provides detailed time variations in charging needs, using the best available data.

7 December 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
MJMahshid Javidsharifi
Mahshid Javidsharifi
Najmeh BazmohammadiNajmeh Bazmohammadi
Najmeh Bazmohammadi
Hamoun Pourroshanfekr ArabaniHamoun Pourroshanfekr Arabani
Hamoun Pourroshanfekr Arabani
Juan C. VasquezJuan C. Vasquez
Juan C. Vasquez
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
This paper presents a comprehensive analysis of the operation management of a multi-node community microgrid (MG), emphasizing power flow constraints and the integration of photovoltaic (PV) and battery systems. This study formulates MG operation management as a multi-objective optimal power flow problem, aiming to minimize costs (maximize profits) and emissions simultaneously. The multi-objective particle swarm optimization (MPSO) method is employed to tackle this complex optimization challenge, yielding a Pareto optimal front that represents the trade-offs between these conflicting objectives. In addition to the normative operation scenarios, this research investigates the robustness of the MG system in the face of abnormal situations. These abnormal scenarios include damage to the PV system, sudden increases in the MG load, and the loss of connection to the main electricity grid. This study focuses on Lombok Island, Indonesia as a practical case study, acknowledging the ongoing efforts to implement the community MG concept in this region. It is observed that when the access to the electricity grid is limited, the energy not served (ENS) increases to 2.88 MWh. During the fault scenario in which there is a 20% increase in the hourly load of each MG, a total of 4.5 MWh ENS is obtained. It is concluded that a resilient operation management system is required to ensure a consistent and reliable energy supply in community MGs in the face of disruptions.