Thunpisit Pothinun

Mr. Thunpisit Pothinun

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2026 in Energies
Verified
Journal Article
Open access
PDF file
TPThunpisit Pothinun
Thunpisit Pothinun
PRPannathon Rodkumnerd
Pannathon Rodkumnerd
SKSirote Khunkitti
Sirote Khunkitti
PWParamet Wirasanti
Paramet Wirasanti
Neville WatsonNeville Watson
Neville Watson
The increasing penetration of distributed energy resources (DERs), electric vehicles (EVs), and dynamic loads introduces significant operational challenges in modern distribution networks, including voltage violations, reverse power flows, and congestion. Distribution network reconfiguration (DNR) is widely used to improve network performance; however, most existing approaches focus primarily on radial topology optimization and rarely consider practical switching feasibility or adaptive transitions between radial and meshed configurations. This paper proposes an operational framework for congestion management based on adaptive radial–mesh reconfiguration. The framework integrates radial network optimization, temporary mesh reinforcement for congestion mitigation, and safe switching sequence validation to ensure operational feasibility. A comprehensive operational cost model incorporating power losses, time-of-use energy imports, switching operations, and on-load tap-changer actions is also developed. The proposed method is validated on a real 22 kV distribution feeder operated by the Provincial Electricity Authority in Thailand. The results demonstrate that the framework effectively mitigates congestion and reduces operational costs by 1.57–9.18% relative to baseline operation, highlighting its practical applicability in active distribution networks.

17 January 2026 in Energies
Verified
Journal Article
Open access
PDF file
PRPannathon Rodkumnerd
Pannathon Rodkumnerd
TPThunpisit Pothinun
Thunpisit Pothinun
SPSuwilai Phumpho
Suwilai Phumpho
Neville WatsonNeville Watson
Neville Watson
ASApirat Siritaratiwat
Apirat Siritaratiwat
SKSirote Khunkitti
Sirote Khunkitti
Effective asset management is crucial for improving the reliability, resilience, and cost efficiency of distribution networks throughout the asset life cycle. Distribution transformers are among the most critical components, as their failures can cause extensive service interruptions and substantial economic impacts. Therefore, robust and transparent maintenance prioritization strategies are essential, particularly for utilities managing several transformers. Traditional time-based maintenance, while simple to implement, often results in inefficient resource allocation. Condition-based maintenance provides a more effective alternative; however, its performance depends strongly on the reliability of indicator selection and weighting. This study proposes a systematic weighting framework for distribution transformer maintenance prioritization using a multi-criteria decision-making (MCDM) approach. Each transformer is evaluated across two dimensions, including health condition and operational impact, based on indicators identified from the literature and expert judgment. To address uncertainty and judgmental inconsistency, particularly when the consistency ratio (CR) exceeds the conventional threshold of 0.10, the Fuzzy Analytic Hierarchy Process (FAHP) is employed. Seven condition parameters characterize transformer health, while impact is quantified using five indicators reflecting failure consequences. The proposed framework offers a transparent, repeatable, and defensible decision-support tool, enabling utilities to prioritize maintenance actions, optimize resource allocation, and mitigate operational risks in distribution networks.

2 September 2024
Verified
Conference Paper
Closed access
TPThunpisit Pothinun
Thunpisit Pothinun
SPSuttichai Premrudeepreechacharn
Suttichai Premrudeepreechacharn
PWParamet Wirasanti
Paramet Wirasanti
WSWatcharin Srirattanawichaikul
Watcharin Srirattanawichaikul
Congestion analysis is crucial for planning distribution networks as it identifies locations of congestion that could lead to power outages and affect system reliability or voltage quality. Through this analysis, network planners can proactively address areas of congestion, guiding the strategic deployment of new infrastructure and upgrading existing networks. This paper presents a congestion analysis framework for long-term distribution network planning aimed at determining the maximum load capacity that a feeder can support during the service restoration process of the Fault location, isolation, and service restoration (FLISR) function without causing network congestion. The proposed framework focuses on congestion analysis, including voltage congestion and overload conditions. The study case uses the real 22 kV distribution network of the Mae Sariang microgrid of the Provincial Electricity Authority (PEA) Thailand, which implemented FLISR function and utilizes the PowerFactory DIgSILENT for simulation.

29 June 2026 in ECTI Transactions on Electrical Engineering, Electronics, and Communications
Verified
Journal Article
Open access
PDF file
TPThunpisit Pothinun
Thunpisit Pothinun
PWParamet Wirasanti
Paramet Wirasanti
Traditional hosting capacity (HC) assessment methods for distribution networks commonly rely on static rule-of-thumb criteria, which often impose overly conservative limits leading to the underutilization of existing network assets. However, modern distribution networks operate under high dynamic load demand and power generation. Addressing these dynamics, this study proposes a congestion-driven framework to enhance HC through optimal radial network reconfiguration. An optimization-based network reconfiguration approach was employed to alleviate congestion and increase HC in the distribution network. Furthermore, the framework integrates the calculation of Dynamic Operating Envelopes (DOE) to allocate active power export and import limits for individual distributed generation (DG) and loads. Validated on a modified IEEE 33-bus system, the simulation results demonstrate that the proposed framework extends the allowable DG penetration from 280% in the static base case to 500%, while simultaneously reducing daily operational costs by up to 12.0%.