This paper presents the reactive power management approach for a medium voltage (MV) distribution grid with inverter-based photovoltaic (PV) distributed generations using a particle swarm optimization (PSO) algorithm. The objective of this research is to control the reactive power flow to support the distribution grid and voltage regulation. The control algorithm is based on centralized reactive power management at the MV distribution grid for allocating the optimal reactive power of each PV distributed generation. The system case consists of a PV system connected to the simple radial feeders in the distributed grid. Simulation studies of the proposed system are built through MATLAB and DIgSILENT PowerFactory software. The simulation results show that the proposed control algorithm is useful for mitigating voltage rise and reverse power flow in the MV distribution grid with the PV generation systems.
22 March 2019 in Turkish Journal of Electrical Engineering and Computer Sciences
This paper presents a discontinuous space vector modulation technique for unbalanced two-phase three-leg inverters. This technique is based on the shift-angle and generalized modulation algorithm obtained for generating the unbalanced two-phase output voltage. Furthermore, the discontinuous switching sequence intends to improve the commutations of power switching devices in each inverter leg that achieves a minimum number of switching state changes in one sampling cycle. Therefore, the switch commutations can be reduced by one-third in one main period. The step- by-step procedure of the modulation algorithm for easy implementation in a digital control platform is discussed. The performance of the developed modulation technique is verified through both simulation and experimental results in a nonunity power factor balanced two-phase load and asymmetrical two-phase induction motor drive.
Congestion analysis is crucial for planning distribution networks as it identifies locations of congestion that could lead to power outages and affect system reliability or voltage quality. Through this analysis, network planners can proactively address areas of congestion, guiding the strategic deployment of new infrastructure and upgrading existing networks. This paper presents a congestion analysis framework for long-term distribution network planning aimed at determining the maximum load capacity that a feeder can support during the service restoration process of the Fault location, isolation, and service restoration (FLISR) function without causing network congestion. The proposed framework focuses on congestion analysis, including voltage congestion and overload conditions. The study case uses the real 22 kV distribution network of the Mae Sariang microgrid of the Provincial Electricity Authority (PEA) Thailand, which implemented FLISR function and utilizes the PowerFactory DIgSILENT for simulation.
As the dramatically increasing power supply of renewable energy (RE) generation penetrates the distribution network, the security of the supply of the network, such as voltage level, is affected by the uncertain power output. The unstable voltage is caused by the tap of the distribution transformer, which is usually a fixed tap. In addition, the locational marginal price (LMP) depends on the number of power supplies from RE generation. The LMP of the whole local system is not lower, although the selling price of RE generation is lower than that of others, which results from the oversupply of RE generation to the network. The Provincial Electricity Authority (PEA) distribution network in Mae Hon Son City is also affected by the high penetration of renewable energy generation (RE generation). Currently, the proportion of power supply from RE generation is approximately 38% (in May) and 143% (in October) of total power supply to the load. During an oversupply of RE generation, the excess power reverses to PEA transmission network at approximately 8.79 MWh, which results in the security of supply and cost efficiency of distribution network companies such as PEA. The locational marginal price (LMP) in case of high penetration of RE generation is, however, slightly the same price as the non-penetration of RE generation under the Thailand electricity market condition. Therefore, the local generation management and dispatching are consequently considered for local power supply and demand balancing, maintaining the security of supply and reducing power losses and locational marginal price.
This paper presents a comparative study of Deterministic and Time-Series methods for evaluating the hosting capacity (HC) of distributed energy resources (DERs), including rooftop photovoltaic (PV) systems and residential electric vehicle (EV) chargers. Simulations were conducted on a low-voltage residential feeder with 18 nodes, each representing a household. PV sizes ranged from 3 to 25 kW and EV chargers from 7.4 to 22 kW. The Time-Series method identified constraint violations more accurately across a 24-hour cycle, while the Deterministic method produced variable results depending on static assumptions—ranging from overly conservative to overly optimistic. Time-Series simulations revealed voltage rise at far-end nodes during midday due to PV export and transformer overloading during evening EV charging. These findings highlight the value of temporal analysis in realistic HC assessment. The Time-Series method is recommended for utility planners due to its ability to reveal when and where violations occur, supporting smarter DER integration strategies.
This paper presents a unified, physics-based framework for Hall-effect characterization in indium arsenide (InAs), incorporating offset-voltage behavior and eliminating eddy-current distortion. The proposed approach integrates theoretical modeling, steady-state experimentation, and numerical optimization into a single, self-consistent methodology capable of isolating the intrinsic Hall response from structural asymmetry and temperature imbalance. In the developed model, the measured voltage is expressed as a linear function of the applied current with an additional constant offset term, and the key parameters are extracted using a least-squares fitting algorithm. The analysis demonstrates strong agreement between simulated and experimental results, confirming high linearity and the effective suppression of parasitic effects. The framework provides a calibration-free and reproducible approach for Hall-effect measurement while offering deeper insights into carrier transport mechanisms. This methodology establishes a robust and extendable foundation for precise semiconductor characterization and can be applied to a broad range of contact-based electronic measurements.