Alireza Hokmabadi

Dr. Alireza Hokmabadi

School of Medicine and Population Health, University of Sheffield, Sheffield, UK
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2022 in Medical Image Analysis
Verified
Journal Article
Open access
AZArezoo Zakeri
Arezoo Zakeri
AHAlireza Hokmabadi
Alireza Hokmabadi
NBNing Bi
Ning Bi
IWIsuru Wijesinghe
Isuru Wijesinghe
MNMichael G. Nix
Michael G. Nix
AGAli Gooya
Ali Gooya
Deformable image registration (DIR) can be used to track cardiac motion. Conventional DIR algorithms aim to establish a dense and non-linear correspondence between independent pairs of images. They are, nevertheless, computationally intensive and do not consider temporal dependencies to regulate the estimated motion in a cardiac cycle. In this paper, leveraging deep learning methods, we formulate a novel hierarchical probabilistic model, termed DragNet, for fast and reliable spatio-temporal registration in cine cardiac magnetic resonance (CMR) images and for generating synthetic heart motion sequences. DragNet is a variational inference framework, which takes an image from the sequence in combination with the hidden states of a recurrent neural network (RNN) as inputs to an inference network per time step. As part of this framework, we condition the prior probability of the latent variables on the hidden states of the RNN utilised to capture temporal dependencies. We further condition the posterior of the motion field on a latent variable from hierarchy and features from the moving image. Subsequently, the RNN updates the hidden state variables based on the feature maps of the fixed image and the latent variables. Different from traditional methods, DragNet performs registration on unseen sequences in a forward pass, which significantly expedites the registration process. Besides, DragNet enables generating a large number of realistic synthetic image sequences given only one frame, where the corresponding deformations are also retrieved. The probabilistic framework allows for computing spatio-temporal uncertainties in the estimated motion fields. Our results show that DragNet performance is comparable with state-of-the-art methods in terms of registration accuracy, with the advantage of offering analytical pixel-wise motion uncertainty estimation across a cardiac cycle and being a motion generator. We will make our code publicly available.

21 November 2016 in International Journal of Microwave and Wireless Technologies
Verified
Journal Article
Closed access
PDF file
AHAlireza Hokmabadi
Alireza Hokmabadi
AKAsghar Keshtkar
Asghar Keshtkar
ABAlireza Bayat
Alireza Bayat
AKAhmad Keshtkar
Ahmad Keshtkar
In this paper, a miniaturized CPW-fed tapered slot antenna (TSA) with a modified CPW to slot-line transition structure was introduced. An air-bridge and tapered slot edge (TSE) structure was also employed to broaden the transition bandwidth. Through these applied modifications, negative features of the original TSA (limitation of transition) and antipodal Vivaldi antenna (bad cross-polarization) are both removed, while all the positive features remained. Results showed that the proposed structure offered a broad bandwidth of 2.6–20 GHz and also exhibited an appropriate current distribution with high radiation efficiency. The radiation pattern was stable in the working frequency band with good directivity, gain, and low cross-polarization. The proposed antenna structure also presented satisfactory time-domain characteristics. In this study, we confirmed the simulation results through data measurements.

24 February 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
TATurki Nasser Alnasser
Turki Nasser Alnasser
AHAlireza Hokmabadi
Alireza Hokmabadi
MSMichael J Sharkey
Michael J Sharkey
AMAhmed Maiter
Ahmed Maiter
KDKrit Dwivedi
Krit Dwivedi
ASAndrew Swift
Andrew Swift
Objectives: To assess the diagnostic accuracy of a fully automated deep learning (DL) model for coronary artery segmentation and calcification detection on non-contrast, non-gated CT scans. Methods: A two-stage 3D segmentation pipeline was developed using 42 non-contrast and 27 contrast-enhanced CT scans to identify coronary artery calcifications in the right coronary artery (RCA), left anterior descending artery (LAD), and left circumflex artery (LCX). The model was trained with anatomically refined labels and region-based optimisation to improve structural coherence. Model outputs were visually assessed in a separate cohort of 100 scans by two independent, experienced observers. Segmentation and detection performance were evaluated against manually annotated reference standards using a binary analysis in 473 internal and external scans. Volumetric measurements of calcifications were compared with baseline severity gradings derived from radiologist reports. Results: Most model outputs were rated as excellent in the visual assessment, with good agreement between the outputs and manual reference standards for coronary artery segmentation (κ 0.68 to 0.81) and calcification detection (κ 0.79 to 0.85). The model accurately detected the presence of calcifications in the RCA (κ = 0.82, p < 0.001), LAD (κ = 0.93, p < 0.001), and LCX (κ = 0.82, p < 0.001). The diagnostic accuracy metrics of the model for calcification detection were: sensitivity, 95%; specificity, 98%; positive predictive value, 99%; and negative predictive value, 88%. The volume of calcification yielded by the model correlated with radiologist-reported disease severity, with regression coefficients of 28.3 for RCA, 28.7 for LAD, and 77.5 for LCX. Conclusions: The developed DL model segmented the coronary arteries, detected the presence of calcifications, and predicted disease severity with high accuracy.

1 December 2016
Verified
Open access
PDF file
AHAlireza Hokmabadi
Alireza Hokmabadi
AKA. Keshtkar
A. Keshtkar
ABA. Bayat
A. Bayat
In this paper, a miniaturized coplanar waveguide fed (CPW-fed) tapered slot antenna (TSA) is introduced for breast cancer detection. Here, a modified CPW to slot-line transition structure with an air-bridge is employed to broaden the transition bandwidth and increase the radiation efficiency. Through these applied modifications, negative features of the original TSA (limitation of transition) and antipodal Vivaldi antenna (bad cross-polarization) are both removed, while all the positive features remained. We have developed a FDTD-UPML method in lossy environment by using Debye model. To validate the results, a prototype of the proposed antenna is fabricated and tested. By immersing the antenna in alcohol ethanol as a lossy coupling medium and inserting it close to a two-layer breast phantom, near-field parameters are calculated in different probe locations. Results show that the proposed structure offers a broad bandwidth of 0.5–19 GHz and also exhibits an appropriate current distribution with high radiation efficiency. Images of energy flux density (EFD) and fidelity factor (FF) confirm the good performance of the antenna in near-field region.

8 October 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
KAKhalid S Alghamdi
Khalid S Alghamdi
AHAlireza Hokmabadi
Alireza Hokmabadi
RGRob J van der Geest
Rob J van der Geest
PGPankaj Garg
Pankaj Garg
TATurki Nasser Alnasser
Turki Nasser Alnasser
ASAndrew Swift
Andrew Swift
Background/Objectives: Pulmonary artery (PA) dilatation and slow-flow are imaging features of pulmonary hypertension (PH), but their quantitative assessment on routine cardiovascular magnetic resonance (CMR) remains limited. This study aimed to develop and evaluate an automated CMR pipeline for quantifying PA size-based and slow-flow metrics from routine white-blood (WB) and black-blood (BB) acquisitions. Methods: A total of 205 CMR acquisitions (106 WB and 99 BB) were used for model development and independent testing. Separate deep learning nnU-Net-based segmentation models were developed for WB and BB acquisitions using a two-stage cascaded framework. Automated measurements included PA volume and PA slow-flow. The trained models were subsequently applied to a larger cohort of 1471 patients using available WB and BB acquisitions to assess automated measurement extraction and agreement with clinical reports. Results: Automated PA volumetric measurements demonstrated excellent agreement with manual reference measurements for both the WB and BB models (ICC 0.94 and 0.93, respectively), with high segmentation accuracy (Dice 0.86 and 0.80, respectively). Automated slow-flow measurements also demonstrated excellent volumetric agreement (ICC 0.94), despite lower spatial overlap (Dice 0.61). Automated slow-flow classification demonstrated 83% agreement with qualitative clinical reporting (κ = 0.58). Conclusions: Automated PA volumetric quantification from routine CMR is feasible. Automated slow-flow quantification showed promising performance but requires validation across scanner vendors and BB acquisition protocols before broader clinical application.