Khalid S Alghamdi

Mr. Khalid S Alghamdi

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2025 in British Journal of Radiology
Verified
Journal Article
Open access
KAKhalid S Alghamdi
Khalid S Alghamdi
AMAhmed Maiter
Ahmed Maiter
GHGeorgia A Hyde
Georgia A Hyde
TATurki Alnasser
Turki Alnasser
MSMichael Sharkey
Michael Sharkey
SASamer Alabed
Samer Alabed
Objectives: Cardiac magnetic resonance imaging (CMR) plays an increasingly important role in non-invasive assessment of pulmonary hypertension (PH). This systematic review aimed to assess the utility, accuracy, and clinical applications of CMR flow techniques in evaluating pulmonary arterial blood flow in patients with suspected or confirmed PH. Methods: MEDLINE and EMBASE databases were searched on December 10, 2024, utilizing the following key terms: “cardiac MRI,” “flow,” and “pulmonary hypertension.” Eligible studies were screened, and data extraction included study design, cohort characteristics, CMR flow techniques and outcomes. Risk of bias was assessed using the Newcastle-Ottawa scale. Results: Thirty-eight studies (mean sample size: 30 [20-57]) published between 2012 and 2024 were included. These utilized 2D flow (19 studies), 4D flow (15 studies), black blood imaging (1 study) and combined flow techniques (3 studies). Vortex duration derived by 4D flow demonstrated the strongest correlation (r = 0.96) with mean pulmonary artery pressure and the highest diagnostic accuracy in identifying PH patients (area under the curve, 0.99). Risk of bias rated 14 studies as good/very good and 13 as unsatisfactory, with none justifying their sample size selection. Conclusion: CMR flow parameters correlate strongly with right heart catheterization measurements and demonstrate high diagnostic accuracy in identifying patients with PH, with 4D flow potentially adding greater value. This systematic review reinforces the potential benefit of CMR flow techniques in the investigation, prognostication, and monitoring of PH patients. Advances in knowledge: This systematic review is the first to evaluate the role of CMR flow techniques in PH and should inform guidelines on flow assessment in PH.

8 October 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
KAKhalid S Alghamdi
Khalid S Alghamdi
AHAlireza Hokmabadi
Alireza Hokmabadi
RGRob J van der Geest
Rob J van der Geest
PGPankaj Garg
Pankaj Garg
TATurki Nasser Alnasser
Turki Nasser Alnasser
ASAndrew Swift
Andrew Swift
Background/Objectives: Pulmonary artery (PA) dilatation and slow-flow are imaging features of pulmonary hypertension (PH), but their quantitative assessment on routine cardiovascular magnetic resonance (CMR) remains limited. This study aimed to develop and evaluate an automated CMR pipeline for quantifying PA size-based and slow-flow metrics from routine white-blood (WB) and black-blood (BB) acquisitions. Methods: A total of 205 CMR acquisitions (106 WB and 99 BB) were used for model development and independent testing. Separate deep learning nnU-Net-based segmentation models were developed for WB and BB acquisitions using a two-stage cascaded framework. Automated measurements included PA volume and PA slow-flow. The trained models were subsequently applied to a larger cohort of 1471 patients using available WB and BB acquisitions to assess automated measurement extraction and agreement with clinical reports. Results: Automated PA volumetric measurements demonstrated excellent agreement with manual reference measurements for both the WB and BB models (ICC 0.94 and 0.93, respectively), with high segmentation accuracy (Dice 0.86 and 0.80, respectively). Automated slow-flow measurements also demonstrated excellent volumetric agreement (ICC 0.94), despite lower spatial overlap (Dice 0.61). Automated slow-flow classification demonstrated 83% agreement with qualitative clinical reporting (κ = 0.58). Conclusions: Automated PA volumetric quantification from routine CMR is feasible. Automated slow-flow quantification showed promising performance but requires validation across scanner vendors and BB acquisition protocols before broader clinical application.