Krista O'Shaughnessey Toler

Mrs. Krista O'Shaughnessey Toler

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2023 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
KTKrista O'Shaughnessey Toler
Krista O'Shaughnessey Toler
PPPearl Ravindra Paranjape
Pearl Ravindra Paranjape
AMAlex McLaren
Alex McLaren
BLBrett Levine
Brett Levine
AOAlvin Ong
Alvin Ong
CDCarl Deirmengian
Carl Deirmengian
Background: Antigen immunoassays to detect synovial fluid (SF) microorganisms have recently been made available for clinical use. The purpose of this study was to determine the sensitivity and specificity of an SF microorganism antigen immunoassay detection (MID) panel, evaluate the panel’s capability to detect microorganisms in the setting of culture-negative periprosthetic joint infection (PJI), and determine diagnostic predictive values of the MID panel for PJI. Methods: This study included 67,441 SF samples obtained from a hip or knee arthroplasty, from 2,365 institutions across the United States, submitted to 1 laboratory for diagnostic testing. All data were prospectively compiled and then were analyzed retrospectively. Preoperative SF data were used to classify each specimen by the International Consensus Meeting (2018 ICM) definition of PJI: 49,991 were not infected, 5,071 were inconclusive, and 12,379 were infected. The MID panel, including immunoassay tests to detect Staphylococcus, Candida, and Enterococcus, was evaluated to determine its diagnostic performance. Results: The MID panel demonstrated a sensitivity of 94.2% for infected samples that yielded positive cultures for target microorganisms (Staphylococcus, Candida, or Enterococcus). Among infected samples yielding positive cultures for their respective microorganism, individual immunoassay test sensitivity was 93.0% for Staphylococcus, 92.3% for Candida, and 97.2% for Enterococcus. The specificity of the MID panel for samples that were not infected was 98.4%, yielding a false-positive rate of 1.6%. The MID panel detected microorganisms among 49.3% of SF culture-negative infected samples. For PJI as a diagnosis, the positive predictive value of the MID panel was 91.7% and the negative predictive value was 93.8%. Among MID-positive PJIs, 16.2% yielded a discordant cultured organism instead of that detected by the antigen test. Conclusions: SF microorganism antigen testing provides a timely adjunct method to detect microorganisms in the preoperative SF aspirate, yielding a low false-positive rate and enabling the detection of a microorganism in nearly one-half of SF culture-negative PJIs. Level of Evidence: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

20 February 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
JPJim Parr
Jim Parr
VTVan Thai-Paquette
Van Thai-Paquette
AWAmy Worden
Amy Worden
JBJames Baker
James Baker
PEPaul Edwards
Paul Edwards
KTKrista O'Shaughnessey Toler
Krista O'Shaughnessey Toler
Background: Accurate diagnosis of periprosthetic joint infection (PJI) remains challenging, particularly in culture-negative and borderline cases where current practices lead to high diagnostic uncertainty. SynTuition™, a machine-learning-based probability score integrating preoperative biomarkers, was developed to support clinical decision-making. This study compared its diagnostic performance and economic impact with standard physician practice. Methods: A total of 12 physicians provided diagnoses of 274 clinical vignettes representing suspected PJI cases. SynTuition probabilities were converted to binary diagnostic classifications using a validated threshold. Diagnostic accuracy, agreement, indecision rates, decision curve analysis, and misdiagnosis-related costs were evaluated. Results: SynTuition achieved an overall percent agreement of 96.0% when compared against the expert adjudicated clinical reference, outperforming the pooled physician group at 90.8%. Physicians showed high indecision (38–48%) in inconclusive 2018 ICM cases, whereas SynTuition generated a definitive diagnosis with an 86.7% agreement against expert adjudication. Decision curve analysis demonstrated a higher net benefit for SynTuition across a broad range of thresholds, reducing projected unnecessary revision by up to 5.8%. Economic modeling showed a reduction in misdiagnosis-related costs from $6.9 million to $2.9 million per 1000 suspected PJI cases, yielding estimated savings of $4000 per suspected case. Conclusions: SynTuition demonstrated high diagnostic accuracy, lower uncertainty, and significant clinical and economic advantages over routine physician practice, supporting its integration into clinical decision-making for suspected PJI, particularly in diagnostically ambiguous cases.

1 July 2024 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
KTKrista O'Shaughnessey Toler
Krista O'Shaughnessey Toler
PPPearl R. Paranjape
Pearl R. Paranjape
AMAlex McLaren
Alex McLaren
CDCarl Deirmengian
Carl Deirmengian
Background: An emerging paradigm suggests that positive Cutibacterium acnes shoulder cultures can result from either true infection or contamination, with true infections demonstrating a host inflammatory response and early culture growth. This clinical retrospective study examines the relationship between C. acnes antigen, C. acnes culture results, and inflammation. Methods: From January 2021 to July 2023, 1,365 periprosthetic synovial fluid samples from 347 institutions were tested for shoulder infection at a centralized clinical laboratory. A biomarker scoring system based on the 2018 International Consensus Meeting (ICM) definition was utilized to assign each sample an inflammation score. Associations between inflammation, culture results, and C. acnes antigen results were assessed utilizing cluster and correlation analyses. Results: Of 1,365 samples, 1,150 were culture-negative and 215 were culture-positive (94 C. acnes and 121 other organisms). Among the 94 C. acnes culture-positive samples, unsupervised clustering revealed 2 distinct sample clusters (silhouette coefficient, 0.83): a high-inflammation cluster (n = 67) and a low-inflammation cluster (n = 27). C. acnes antigen levels demonstrated moderate-strong positive correlation with inflammation (Spearman ρ, 0.60), with 166-fold higher levels of C. acnes antigen in high-inflammation samples (16.6 signal/cutoff [S/CO]) compared with low-inflammation samples (0.1 S/CO) (p < 0.0001). The days to C. acnes culture positivity demonstrated weak-inverse correlation with inflammation (Spearman ρ = −0.38), with 1.5-fold earlier growth among the 67 high-inflammation samples (6.7 compared with 10.4 days; p < 0.0001). Elevated C. acnes antigen was observed in only 4 (0.38%) of 1,050 low-inflammation culture-negative samples and in only 5 (4.9%) of 103 high-inflammation non-C. acnes-positive cultures. However, 19.0% of high-inflammation, culture-negative samples demonstrated elevated C. acnes antigen. Conclusions: Synovial fluid C. acnes antigen was detected among shoulder samples with high inflammation and early culture growth, supporting the emerging paradigm that these samples represent true infection. Future research should explore antigen testing to differentiate contamination from infection and to identify culture-negative C. acnes infections. Level of Evidence: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

13 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
JPJim Parr
Jim Parr
VTVan Thai-Paquette
Van Thai-Paquette
AWAmy Worden
Amy Worden
JBJames Baker
James Baker
PEPaul Edwards
Paul Edwards
KTKrista O'Shaughnessey Toler
Krista O'Shaughnessey Toler
Background: Accurate diagnosis of periprosthetic joint infection (PJI) remains challenging, particularly in culture-negative and borderline cases where current practices lead to high diagnostic uncertainty. SynTuition™, a machine-learning–based probability score integrating preoperative biomarkers, was developed to support clinical decision-making. This study compared its diagnostic performance and economic impact with standard physician practice. Methods: A total of 12 physicians provided diagnoses of 274 clinical vignettes representing suspected PJI cases. SynTuition probabilities were converted to binary Diagnostic classifications using a validated threshold. Diagnostic accuracy, agreement, indecision rates, decision-curve analysis, and misdiagnosis-related costs were evaluated. Results: SynTuition achieved an overall percent agreement of 96.0% when compared against the expert adjudicated clinical reference, outperforming the pooled physician group at 90.8%. Physicians showed high indecision (38–48%) in inconclusive 2018 ICM cases, whereas SynTuition generated a definitive diagnosis with an 86.7% agreement against expert adjudication. Decision curve analysis demonstrated higher net benefit for SynTuition across a broad range of thresholds, reducing projected unnecessary revision by up to 5.8%. Economic modeling showed a reduction in misdiagnosis-related costs from $6.9 million to $2.9 million per 1,000 suspected PJI cases, yielding estimated savings of $4,000 per suspected case. Conclusions: SynTuition demonstrated high diagnostic accuracy, lower uncertainty, and significant clinical and economic advantages over routine physician practice, supporting its integration into clinical decision-making for suspected PJI, particularly in diagnostically ambiguous cases.

12 March 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
DGDerese Getnet
Derese Getnet
TKTaejun Ko
Taejun Ko
DLDeyu Liu
Deyu Liu
BYBuyu Yeh
Buyu Yeh
JDJennifer Dootz
Jennifer Dootz
XLXiaonao Liu
Xiaonao Liu
Rapid and actionable pathogen identification remains a major unmet need in the diagnosis of prosthetic joint infection (PJI). Current diagnostic approaches either provide rapid host response information without pathogen specificity or identify pathogens with delays of days to weeks. Here, we report a chemiresistive nanosensor array combined with machine learning analysis for same-day, pathogen-specific detection based on volatile organic compound (VOC) profiling. A 19-channel nanosensor array was first validated in vitro against a panel of ESKAPEE pathogens, achieving 96% mean classification accuracy using a radial-basis-function support vector machine (SVM) classifier. Data-driven optimization yielded a reduced six-sensor array with high signal-to-noise performance. The optimized platform was evaluated using pooled, uninfected human synovial fluid enriched 1:1 with nutrient media and spiked with Staphylococcus aureus, Staphylococcus epidermidis, or Pseudomonas aeruginosa across a range of 1–106 CFU/mL. All infected samples were detected within 9 h, with distinct VOC signatures enabling accurate pathogen differentiation. Time-to-detection (TTD) demonstrated a strong inverse correlation with initial bacterial concentration, supporting semi-quantitative estimation of bacterial load. Negative controls remained at baseline throughout testing. This chemiresistive VOC-based biosensor platform demonstrates the potential to deliver rapid, integrated detection, identification, and burden estimation of metabolically active PJI pathogens, highlighting its promise for future point-of-care diagnostic applications.