Objective: To analyze predictive factors of outcome after primary stapes surgery for otosclerosis. Study Design: Retrospective review of 139 patients with otosclerosis and 147 operations performed by the same senior surgeon with the same surgical technique. Setting: Academic hospital and tertiary referral center. Patients: All patients had documented preoperative and peroperative audiologic assessments and preoperative records. The mean age of patients was 44.31 years. Intervention: Stapedotomy with diode laser using Teflon prosthesis. Main Outcome Measures: The bone conduction threshold changes, the improvement of pure-tone average air-bone gaps (PTA-ABGs), and ABGs for each frequency were analyzed using 0.5, 1, 2, and 4 kHz. Success rate was defined by postoperative ABG. Log-rank test was used to define significant factors. Results: At 24 hours postoperative, there was a significant deterioration in bone conduction threshold at 1, 2, and 4 kHz. However, at 4 kHz, the threshold remained significantly worse at longer term. There was a significant improvement of the PTA-ABG. Eighty-six percent of patients obtained a PTA-ABG of 20 dB or less. We also obtained a significant ABG closure on every frequency except on 4 kHz. Multivariate statistical analysis had not identified a predictive factor of hearing outcomes such as the anatomy of the facial nerve, the incus, the stapes footplate and the external auditory canal, the prosthesis crimping, bleeding, and surgical damage of the tympanic membrane. Conclusion: In experienced hands, we observed a significantly transient depression of bone conduction hearing levels that was definitively present at 4 kHz. Peroperative difficult or abnormal situations did not seem to have an influence on the hearing outcome. Those statements will enable accurate preoperative counseling. It will also permit precise matching of future series to allow accurate comparisons.
Background: The aim of this study was to relate response patterns of electrocochleography (ECochG) recordings during cochlear implantation to pre- and postoperative hearing. Methods: Thirty subjects with either flat (FA, n = 9) or sloping (SA, n = 21) audiograms before cochlear implantation were prospectively included. Real-time ECochG recordings were conducted via the cochlear implant. The difference curve (DIF) signal of the ECochG recordings was analyzed regarding alteration of the waveform, amplitude changes, and relative phase shifts during insertion. Results: Five subjects (56%) with FA and 13 (62%) with SA exhibited DIF signal drops in the early phase of the insertion. In subjects with FA, alterations of the DIF signal waveform in the early phase of the insertion occurred in 8 subjects (90%), whereas such changes were detectable in only 2 out of 21 subjects (10%) with SA (p < 0.001). DIF signal drops with relative phase shifts of >0.7 radians but without alterations of the waveform occurred in 5 subjects (56%) with FA and 11 (52%) with SA. Such drops were associated with larger postoperative hearing losses than DIF signal drops without phase changes in both groups (FA: 43 versus 20 dB, p = 0.045; SA: 30 versus 14 dB, p = 0.001). Conclusion: Residual cochlear function in basal regions leads to alteration of the DIF signal waveform during insertion, probably not associated with cochlear injury. A decrease of the DIF signal amplitude with a simultaneous relative phase shift but no alteration of the waveform is associated with greater loss of residual hearing independent from the preoperative hearing.
Background: Otology training solely using cadavers is challenging because of scarcity and high costs. The use of additive manufacturing technology is a promising alternative. This study aimed to qualitatively validate new additive manufacturing temporal bone specimens for their realism and ability to train surgical skills.Methods: Three additive manufacturing models generated using cadaveric temporal bones were evaluated. Three otologists with experience as trainers dissected and evaluated each specimen.Results: The additive manufacturing specimens scored an average of 4.26 ± 0.72 (out of 5) points and received positive feedback. The agreement between the three expert raters was high (intra-class correlation coefficient of 0.745).Conclusion: The results suggested that the additive manufacturing temporal bones were able to faithfully reproduce a training experience similar to that on cadaveric temporal bones. Further studies that investigate the effectiveness of these specimens in training surgical skills are needed before integrating them into surgical training curricula.